TPX24SIBABS General Electric Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- George from Cun City Center, FL
- Parts Used:
- WR17X3909
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
The shield light had burned the shield
I hung the new shield on the two inside pegs that were already there.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jerry from Poquoson, VA
- Parts Used:
- WR57X10051
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
My icemaker was leaking down the back wall of the freezer (side-by-side unit) building a huge ice flow that grew into the path of the circulation fan.
After turning the water off, I removed the two screws holding the cover on the lower back of the freezer. I disconnected the copper water supply line from the valve. I then removed the screw holding the valve in place and removed it from the freezer. I removed the two wires from the valve and placed them on the new valve (after inserting the clip inserts to match the new size tabs).I pulled the two plastic water lines out of the valve and inserted them into the new valve. I put the new valve in place and replaced the screw. Total time less than 15 minutes. Much easier to fix, than to identify the problem. The collective wisdom of the internet strikes again! Thanks to all.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- George from Old Bethpage, NY
- Parts Used:
- WR57X10051
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Wrench (Adjustable)
Leaky valve
Removed three screws, water input line, two water output lines. The new valve had push on fittings instead of screw on, so had to cut the old fittings off. Connecte input and output lines Replaced three screws holding valve in place. Turned water back on. Finished.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Chester from Chambersburg, PA
- Parts Used:
- WR57X10051
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Wrench (Adjustable)
Valve leaked water and needed to be replaced
First I removed the incoming water line from the valve. I then removed the screw that hold the valve in place. Then I pulled the element out about 3 inches and disconnected the two connector wires. Next I cut the plastic hoses from the old valve.
To install the new valve, I inserted the two plastic hoses into the new valve. (hoses are different diameters so it is next to impossible to insert them incorrectly.) I replaced the electrical connectors (This was the only glitch since the one connector on the refrigerator is larger then the pins on the new valve, A little electrical tape held the connector in place.) I then tightened the screw that holds the valve on the refirgerator and reconnected the household water to line to the valve.
The entire job took less time then it has taken me to type the procedure.
To install the new valve, I inserted the two plastic hoses into the new valve. (hoses are different diameters so it is next to impossible to insert them incorrectly.) I replaced the electrical connectors (This was the only glitch since the one connector on the refrigerator is larger then the pins on the new valve, A little electrical tape held the connector in place.) I then tightened the screw that holds the valve on the refirgerator and reconnected the household water to line to the valve.
The entire job took less time then it has taken me to type the procedure.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Bobby A from Del City, OK
- Parts Used:
- WR57X10051
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
No water going into ice maker
Pulled the fridge out from the wall, disconnected the power cord,turned off the water supply,removed the backing that covers the fan/motor and the two way water valve. Removed one screw that holds water valve to back of fridge,removed two water lines. Installed the new water valve , connected water lines and screw, installed back dust cover, plugged in the 110 cord, turned on the water valve. Within 30 minutes a new tray of ice cubes was ejected into the ice holding box. Mission completed.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Tom from Forest, VA
- Parts Used:
- WR57X10051
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
leak from duel inlet water valve
Pulled unit away from wall. Removed lower panel. Turned off water and electricity. Removed two nuts holding valve. Disconnected electrial wiring. Cut water lines going into old valve close to the valve so the lines could be reused with new unit. Installed new valve by pressing lines into valve, reconnected electricity. Put two screws back in. Turned on water and electricity. Works great. No leaks. Results of leaks required hardwood floor to be repaired (sanded and refinished). Stayed away from kitchen for nine (9) days. Need to check for leaks everytime you clean under the refrigerator.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Lynn from White Pine, TN
- Parts Used:
- WR57X10051
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Socket set, Wrench (Adjustable)
leaking water inlet valve
Changing the valve was easy, remove and replace. The problem came afterwards. After shuting off the water and waiting for the replacement valve, the water line coming in to the icemaker froze solid causing water to spray into the freezer, causing a major leak. After thawing out the line, it still leaked because the water in the freezer had frozen up the freezer drain again causing another leak.Bottom line, after replaceing the valve, take a few extra minutes to check or replace the water line coming to the icemaker. That will save a headache later.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- percy from rosenberg, TX
- Parts Used:
- WR57X10051
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers, Wrench (Adjustable)
water kept freezing in tube to icemaker
removed backing from the refrigerator then unscrewed the pump from refrigerator unhooked the electrial connections. Then hooked up new pump by connectioning the elctrical then putting water connections back on with the quick connects then plugged refrigetator back in the reinstalled back of refrigerator and slide back into place as simple as 123
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Boyd from Rapid City, SD
- Parts Used:
- WR02X10098
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
The evaporator fan in the freezer compartment began making a loud noise.
I found a replacement evaporator fan motor and 2 mounting bracket grommets at PartSelect.com at a reasonable price. I watched the installation video provided and installed the new parts as shown in the video start to finish installation time 22 minutes.i
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Malik from Lathrup Village, MI
- Parts Used:
- WR57X10051
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Ice build up in the freezer
It is a dream with less than a minute I unscrew the old part and install the new part
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Linda from Pittsfield, MA
- Parts Used:
- WR57X10051
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Wrench (Adjustable)
the original part had gotten a tiny pinhole in the plastic at the seam, probably due to age
After turning the water off and unplugging the refridgerator, I took the copper inlet tubing off using an adjustable wrench. I disconnected the two fuses that give power to the unit, and using a screwdriver, disconnected the water inlet/ outlet tubing from the old unit. I pushed the tubing into its proper place in the new unit, plugged in the two color coded fuses, used a wrench to reconnect the copper water tubing, and replaced the unit. EASY!!! So, easy, in fact that a non-handy girl could do it (and I can say that, being a non-handy girl!)
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Wes from Blue Springs, MO
- Parts Used:
- WR57X10051
- Difficulty Level:
- Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Pliers, Screw drivers, Wrench set
Years ago the water valve leaked then recently the ice valve leaked.
Shut the water off to it. Carefully moved the refrigerator away from the wall to avoid damage to the copper piped water. Removed the cardboard cover at the bottom and rear. Layed a towel down to catch water. unscrewed the copper water line from the leaky double valve unit. Removed the old double valve unit by unscrewing the single support screw. Installed the new unit in reverse order without following the directions that suggested using the old support structure. Took the opportunity to vacuum the cooling coils while back there, but broke an impeller on the cooling fan which is requiring further maintenance. Be careful!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jeffry from Athens, IL
- Parts Used:
- WR57X10051
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Wrench (Adjustable)
Water valve was bad, no power!
First I removed the screw holding the valve in place. I then pulled the valve out about 3 inches and disconnected the two wires and water line.
I repaced the old valve with the new valve and performed the steps in reverse order and the ice maker was making ice that night. I however developed a leak and had to have another valve sent. The problem has been solved and all is well.
Parts select has been fast, friendly and helpful through my whole experience. I would like to say thanks for all your courteous help and hopefully this will help others realize the benefit of Parts select to us do-it-ourselfer!.
Thank you!
Jeff Lopian
Athens, Illinois
I repaced the old valve with the new valve and performed the steps in reverse order and the ice maker was making ice that night. I however developed a leak and had to have another valve sent. The problem has been solved and all is well.
Parts select has been fast, friendly and helpful through my whole experience. I would like to say thanks for all your courteous help and hopefully this will help others realize the benefit of Parts select to us do-it-ourselfer!.
Thank you!
Jeff Lopian
Athens, Illinois
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Tammy from Rudy, AR
- Parts Used:
- WR57X10051
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers, Wrench (Adjustable)
water was running out of the water inlet tube on the ice maker
Unpluged frig . Removed back at bottom of frig . Removed mounting bracket, removed two water supply tubes diconnected two electical plugs fron water valve
Then installed new valve in reverse order. Except for plastic housing which required some manipulation /squeezed to fit it worked great
P.S.don't forget to turn off water supply to frig. Ha Ha
Then installed new valve in reverse order. Except for plastic housing which required some manipulation /squeezed to fit it worked great
P.S.don't forget to turn off water supply to frig. Ha Ha
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Anthony from Westminster, CO
- Parts Used:
- WR57X10051
- Difficulty Level:
- Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Pliers, Screw drivers
Icemaker cycling, but not producing ice
removed two screws holding water valve in place; pull out valve and remove water supply line; remove two water lines going into box; connect lines to new valve and reinstall
Was this instruction helpful to you?
Thank you for voting!