- Customer:
- Gerald from WINTERVILLE, GA
- Parts Used:
- 40A15
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
lights blown out
replaced lights in refrigirator and freezer
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Thomas from Grapevine, TX
- Parts Used:
- WR57X10051
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Wrench (Adjustable)
water dispenser/ice maker wouldn't work
Unplugged refrigerator and turned off water valve at wall. Removed the entire back, lower cardboard panel (turns out I didn't have to do this...could have just removed the screws from the right side and folded the cardboard along a perforated line designed for that purpose). Removed screw holding water control valve to back of refrigerator. Took new control valve, and slipped on adaptors for electrical connectors (in bag) to the two smaller of the four electrical prongs). Removed electrical sockets from old connector and placed them over appropriate prongs on new connector. Unscrewed the two old water out lines, cut the old fittings off and slipped the lines snugly into the new outlet valve (new valve had slip on connectors not requiring lines to be screwed in). Keep straight which line goes to which outlet port! Then removed water line going into old fitting and screwed it on to new valve inlet fitting (after removing black plastic protective cap). Turned wall water valve on, checked for leaks (none), and plugged refrigerator back in. Water restored to both icemaker and water dispenser!
By the way, the first valve came damaged, but one phone call and the people at Part Select promptly sent out a replacement which I had the very next day (and this was two days before Christmas!). Great job!
By the way, the first valve came damaged, but one phone call and the people at Part Select promptly sent out a replacement which I had the very next day (and this was two days before Christmas!). Great job!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Tony from Conover, NC
- Parts Used:
- WR57X10051
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Wrench set
Water leak from the Water Valve.
I received my parts in 2 days, that is fast. It took me less than 15 minutes to install the unit. Now I've got ice and water from my refrigerator. Instead of taking expensive warranties, I would rather order parts from your company and do it myself on all my appliances.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ruben from Sylmar, CA
- Parts Used:
- WR57X10051
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers, Wrench (Adjustable)
Leaking water
Be careful when ordering the part. Make sure you need a Double or Single Outlet Water Valve. They look almost the same in the catalog.
Unplug the power cord and turn off the stopcock water supply valve. Unplug the 2 electrical jacks and pull-out the water hose from the compression type fitting. Use a philips screwdriverdriver to remove the bad part. Install the new part in the reverse steps.
Unplug the power cord and turn off the stopcock water supply valve. Unplug the 2 electrical jacks and pull-out the water hose from the compression type fitting. Use a philips screwdriverdriver to remove the bad part. Install the new part in the reverse steps.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Brad from SPRING MILLS, PA
- Parts Used:
- WR02X10098
- Difficulty Level:
- Very Difficult
- Total Repair Time:
- More than 2 hours
Noisy
I didn’t do the repair because I ordered two grommets. When they arrived, one of the packages was empty! Instead of just sending me another one, they refunded the part so I still need one. By the way, I was not refunded half the shipping either which was more than the part itself.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Joey from Travelers Rest, SC
- Parts Used:
- WR57X10051
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers
The water valve was leaking
I Took the six screws off the back panel to get to underneath the refridgerator. took the 2 screws out of the bracket thast holds on the water valve took the 2 lines off and then put everything back
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from Columbia, MO
- Parts Used:
- WR57X10051
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Wrench (Adjustable)
Body case seal gone bad on water valve
Easy. First, unplug the fridge.
1)Shut off then disconnect water line.
2)Remove water valve mount screw.
3)Disconnect electrical plugs and snip water lines (square cut lines for new valve).
4)Simply insert and seat water lines into their respective places on the new valve. Using adapters as needed, reconnect electrical plugs.
5)Mount valve and reconnect water line.
6)Turn on water supply and check for leaks. Possible leaks: water line or not fully seated lines to the new valve.
7)Restore power and enjoy :o)
1)Shut off then disconnect water line.
2)Remove water valve mount screw.
3)Disconnect electrical plugs and snip water lines (square cut lines for new valve).
4)Simply insert and seat water lines into their respective places on the new valve. Using adapters as needed, reconnect electrical plugs.
5)Mount valve and reconnect water line.
6)Turn on water supply and check for leaks. Possible leaks: water line or not fully seated lines to the new valve.
7)Restore power and enjoy :o)
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Roscoe G from ROCHESTER, NY
- Parts Used:
- 40A15
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
Light burnt out.
Turned the wire protector to the side. Turned out the old bulb and replaced it with the new. Turned the wire protector back in place and I'm like new.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Christine from Delray Beach, FL
- Parts Used:
- WR17X10542
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
drawer facing cracked
ordered drawer face - perfect part- snapped right in. done. order came within 10 days.
will order again if needed.
will order again if needed.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Henderson from Holladay, TN
- Parts Used:
- WR57X10051
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers
After the ice dumped, the tray would overfull and run over into the freezer
The operation is very simple on this valve. I disconnected the water lines and wires.
Then two I removed the two screws attaching
valve to the ref.box.
The reinstall is just the opposite from removal.
Then two I removed the two screws attaching
valve to the ref.box.
The reinstall is just the opposite from removal.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Wendell Hayes from Dillob, SC
- Parts Used:
- WR60X187
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Fridge wasn't cooling and half freezing
Part was perfect fit .Removed fan .three screws.replaced that s it
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from Mechanicsville, MD
- Parts Used:
- WR57X10051
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Wrench set
Leaking Inlet Water Valve
Very quick and easy repair. Took off cover to access valve using standardr screw driver. After shutting off water supply to valve disconnected copper water supply line. Used a large towel to catch any residual water in line. Removed two water lines on valve use plies if more than hand tight to loosen. Removed screw holding valve in place, removed valve and disconnected wires (be sure power to frig is off least you get a shock. Reverse proceedure to install new valve. new valve has simple push in connections for plastic water lines. Install two electrical adpaters and electric lines. Mount valve with screw, connect copper water line. Turn water back on and check for leaks. Turn power on and check for proper water running at dispenser. Again check for any leaks. No leaks, install cover and you are done.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Rehn from Austin, TX
- Parts Used:
- WR57X10051
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Wrench set
Ice maker would not work
Disconnected the power and then the water line. Removed the cardboard shield on back of the refrig. Then removed the faulty solenoid which was held in place by one bolt. Removed the two plastic water hoses and two sets of electrical connectors. I then reversed the process to install the new solenoid. I encountered two challenges. The new solenoid had a plastic housing that had to be removed and one set of the electrical connectors required an extension. The extensions were included with the solenoid, but there were no instructions.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Donald from Pinnacle, NC
- Parts Used:
- WR57X10051
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Wrench (Adjustable)
The water dispenser in the door would drip continuously .
Used the parts diagram from PartSelect.com to locate the valve. Removed the old valve and disconnected inlet water line and the 2 outlet water lines(one for ice maker & one for water dispencer). Reconnected water lines to new valve and positioned it back in place on the refrigerator. Problem solved -no more drip, drip, drip.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Michael from NAUGATUCK, CT
- Parts Used:
- WR57X10051
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers, Screw drivers, Socket set, Wrench (Adjustable)
Ice Maker was not making ice
Followed the instructions in the video, which showed our exact refrigerator. Very easy instruction, for a simple job. However, it did not fix the problem. At this point I suspect a faulty replacement part (which cannot now return), or some other issue requiring further analysis. Could also be that the original Inlet Water Valve is not at fault, which means that this high probability fix (70%) was not needed.
Was this instruction helpful to you?
Thank you for voting!