TPX24SIBABS General Electric Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- anthony from DUMFRIES, VA
- Parts Used:
- WR57X10051
- Difficulty Level:
- Very Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Wrench (Adjustable)
no water going into ice maker
follow the video
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Philip M. from SIMPSONVILLE, SC
- Parts Used:
- WR32X1461
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
GE vegetable drawer broken.
Concerned about removing and attaching front panel to broken drawer. Rep. said wasn't sure but most just snapped together. Rep. was correct. No tools required.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from PARKVILLE, MO
- Parts Used:
- WR02X10098
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Socket set
Had a 'ticking' sound
Separately (from a different site) purchased new compressor fan and motor. I purchased the grommets here because the other site listed the grommets as temporarily out of stock. I did watch one of the videos on PartSelect about the grommet replacement. Repair was pretty simple, biggest challenge was getting to the screw on the far side of the motor. Removed the two screws holding the fan motor into place. Removed motor and blade. Reinstalled with new fan blade, new grommet and new motor.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from LOS ALAMITOS, CA
- Parts Used:
- WR57X10051
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Screw drivers, Socket set, Wrench (Adjustable)
No water supply to ice maker
Received the first water valve with very poor included instructions. Watched the suggested instructional YouTube for my part installation which was very well done except my new part was not identical to my old part or the one in the YouTube. A translucent plastic housing on the part obstructed the installation so I needed to trim part of it away with a tin shear before attaching the part to the refrig. The waterline attachments were slip fit rather than what my old part had with compression nuts. I replaced all the plastic water lines using the slip fittings, turned the water back on and- all fittings leaked. Undid the fittings, trimmed the water lines and reattached- still leaked. So I contacted customer service who sent out a new part and followed the above procedure and everything went quickly with no leaks. I suggest you replace the two plastic water lines ( you will need to buy two slip fittings and two diameter lines) these are available at Home Depot. There is also a YouTube for this and it is a must see. My main supply line to the refrigerator is copper tubing. I trimmed the end of the tubing, filed it smoot, steelwooled the surface and installed a new brass compression ring befor reactching to the valve. Note, because of the first leaks, I found it easier to make all my connections including the electrical, plug the refrigerator back in and active the ice maker and water dispenser before reaching the valve the the frig back. Good luck.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Timothy from Atlanta, GA
- Parts Used:
- WR57X10051
- Difficulty Level:
- Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Screw drivers
Bought a used refrigerator, hooked up water line, and water poured out of icemaker.
This should have been an extremely easy, quick job, but because I'm not that familiar with refrigerator parts, and NO INSTRUCTIONS came with the part, it took quite a while. The fittings for the water lines to icemaker and water outlet were dramatically different from the old part. The old part had screw-on fittings. The new one did not. I went first to Ace hardware-they had never seen fitting like this, and didn't know what to tell me. I drove 20 minutes to Home Depot, and the guy there told me that, rather then screwing on, or needing another part, the fittings were a quick connect, where you just shove the plastic tubing into the fitting. Finally an answer!
I went home, did as he'd said, hooked it up (shoved the tubing in, used the provided electrical adapters for the contacts, and screwed the thing on. It takes a good while for the icemaker to get cold enough to start it's cycle (which I found out from an internet search), and about 6 hours later, I started getting ice. It works fine now, love the in the door water/ice on my "new" 10-12 year old $75 plus $35 for the part-huge 26.6 side by side refrigerator, but the part should have had at least an indication that the water fittings just needed to have the tubing shoved into them.
I went home, did as he'd said, hooked it up (shoved the tubing in, used the provided electrical adapters for the contacts, and screwed the thing on. It takes a good while for the icemaker to get cold enough to start it's cycle (which I found out from an internet search), and about 6 hours later, I started getting ice. It works fine now, love the in the door water/ice on my "new" 10-12 year old $75 plus $35 for the part-huge 26.6 side by side refrigerator, but the part should have had at least an indication that the water fittings just needed to have the tubing shoved into them.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mark from Dumfries, VA
- Parts Used:
- WR57X10051
- Difficulty Level:
- Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Screw drivers, Wrench (Adjustable)
Water Valve Leaking
Removed lower cover screws removed cover removed copper water feed tubing connector unplugged wire connectors pulled out plastic water line connector and water lines removed water valve assembly installed water lines installed wire connectors secured valve assembly reinstalled copper water line turned on water valve checked for leaks reinstalled lower rear cover
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- ROBERT from STOW, OH
- Parts Used:
- WR57X10051
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers, Wrench set
no ice
Removed cardboard cover from back of refrigerator with nutdriver. Removed old pump and reconnected water lines and electrical. reinstalled pump.It did take about 5-10 minutes for the pump to refill ice tray.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from Somerset, KY
- Parts Used:
- WR57X10051
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Socket set, Wrench (Adjustable)
water wouldn't shut off
replaced solenoid
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- kathleen from red oak, TX
- Parts Used:
- WR57X10051
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers, Wrench set
leaking water valve
I used a screwdriver to remove, then replace, the screw that holds in the valve. I used pliers to pull the refer water line out of the old valve. I just used my hands to reinstall the line. I used and open box wrench to remove and reattach the main water line. Nothing blocked access to the valve and it was very easy to remove the old one and install the new one.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Johnathan from Gilbert, AZ
- Parts Used:
- WR57X10051
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Wrench (Adjustable)
Ice maker overflowing. Valve stuck open
The valve I got was slightly bent up. I spent the first 10 minutes or so bending it back with my muscles. once that was done, I took off the backing of the fridge with the screwdriver, undid the single bolt holding the valve on, and unplugged it all (fridge was already unplugged). Just like everyone says, the tubing connecter is different, so I took off the old compression fittings, and pushed the tubes in. THen I hooked up the wiring... I realized that that the wiring adapter was needed but there wasn't enough room for it as is.. so I have to bend the tabs so the wiring would angle down. Everything has worked perfect since... I got Ice and no leaks! woo hoo!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Karen from Gainesville, FL
- Parts Used:
- WR57X10051
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Wrench (Adjustable)
ice maker stopped working
I unplugged the refrigerator and shut off the water. I removed the back of the frig where the inlet valve is located. I removed the old nuts and cut the plastic water line on the ends. I shoved them into the new fittings. I then turned on the water and plugged in the frig. I could hear the water pumping into the ice maker. I screwed the inlet and back of refrigerator in place.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Louis from LEAGUE CITY, TX
- Parts Used:
- 40A15
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
Change bulb
Easy
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Gary from Groesbeck, TX
- Parts Used:
- WR57X10051
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Wrench (Adjustable)
water over filling ice tray and leaking into ice tray and freezing
Followed the directions on the web site and did everything that was instructed to do and had no problems with installing the new dual water Valve. Has been in now for a week and no more over filling or freezing water in the storage box. Lots of clean ice, now!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from Chapel Hill, NC
- Parts Used:
- WR57X10051
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers
Leaking valve
The valve was leaking from the core and not the in/out tubes. The valve is easy to get to and very easy to replace. When replacing the water in/outs you cut them off the old valve and then slip them on the new valve. 5 to 10 minute job.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Craig from Land O Lakes, FL
- Parts Used:
- WR57X10051
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers
Water flow was too low
Turn off water valve to the refigerator and disconnect line.
Remove the cardboard backing and insulation.
Remove old valve and cut lines close to the valve.
Trim plastic on new valve as needed to fit (generic valve).
Insert water lines into new valve.
Install new valve.
Connect water line and open valve.
Replace cardboard backing and insulation.
Remove the cardboard backing and insulation.
Remove old valve and cut lines close to the valve.
Trim plastic on new valve as needed to fit (generic valve).
Insert water lines into new valve.
Install new valve.
Connect water line and open valve.
Replace cardboard backing and insulation.
Was this instruction helpful to you?
Thank you for voting!