Condenser fan motor seized
While investigating a water leak I discovered the condenser fan seized. I removed the fan to prevent a fire and ordered the part. The hardest part was identifying the correct fan. That took longer than the installation.
I cut the wires and spliced in the new motor. It rotated correctly and I replaced the crill.
Done
Total time of ice maker water leak repair and fan replacement about 1 hour.
I cut the wires and spliced in the new motor. It rotated correctly and I replaced the crill.
Done
Total time of ice maker water leak repair and fan replacement about 1 hour.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Lance from Wapello, IA
- Parts Used:
- WP67005154
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Socket set
leaking water
removed the old valve from back of fridge by removing screws that held mounting plate. removed water lines by pushing in on quick connects and pulling hoses out. A little different type of connections. installed new valve and pushed hoses into connections making sure that they snaped in. reinstalled screws and checked for leaks. took about 15 minutes!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Steven from Brigham City, UT
- Parts Used:
- 833697
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
condenser fan stopped working
1. Removed the cardboard cover.
2. Removed the terminal block and unplugged the old motor.
3. Removed three screws that held old motor to the bracket.
4. Removed the fan blade from the old motor.
5. Installed the fan blade (after cleaning) to the new motor.
6. Crimped on new wire terminals onto the leads on the new motor.
7. Installed the new motor using the fasteners provided.
8. Plugged the new motor wires onto the proper terminals in the terminal block.
9. remounted the terminal block.
10. reinstalled the cardboard cover.
2. Removed the terminal block and unplugged the old motor.
3. Removed three screws that held old motor to the bracket.
4. Removed the fan blade from the old motor.
5. Installed the fan blade (after cleaning) to the new motor.
6. Crimped on new wire terminals onto the leads on the new motor.
7. Installed the new motor using the fasteners provided.
8. Plugged the new motor wires onto the proper terminals in the terminal block.
9. remounted the terminal block.
10. reinstalled the cardboard cover.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- dennis j from TOMAHAWK, WI
- Parts Used:
- WPW10503278
- Difficulty Level:
- Very Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
frig would not get cold
I watched video for repair and it went just like it showed. piece of cake
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- JAMES from Middleboro, MA
- Parts Used:
- 833697
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers, Socket set
Freezer Cooling Problems - would get too warm then too cold. Condenser fan would run sometime but not always
Unplug
Remove entire back panel (both chipboard and metal fan grill)
Unscrew both fan mount plate screws - fan won't be able to come out because it is still plugged in
When looking at back of fridge, locate a small plastic box to the immediate left of the condenser. It's a circuit block. Release the metal spring clip holding the plastic cover in place, and trace the fan wire connections back to the fan. Make a note of which wire is connected to which terminal (1 of the fan wires has white lettering and 1 is just black)
Unplug both fan wire connects from circuit block to release the fan power cable.
Remove the fan mounting plate
Release fan blade clip by pressing fan against motor and unscrewing and remove fan blades
Unscrew motor from brackets - note alignment of motor on brackets
Mount new motor on brackets. Leave plug wire disconnected (replacement motor has a harnessed plug wire)
Connect new plug wire to the circuit block keeping wires connected to the proper terminals
Snake new plug wire behind condenser like the old wire was and run through cable bracket to the back right of the condenser
Plug wire harness into motor and re-mount fan mount plate
Reattach fan blade and secure using blade mount kit
Replace back panels
Remove entire back panel (both chipboard and metal fan grill)
Unscrew both fan mount plate screws - fan won't be able to come out because it is still plugged in
When looking at back of fridge, locate a small plastic box to the immediate left of the condenser. It's a circuit block. Release the metal spring clip holding the plastic cover in place, and trace the fan wire connections back to the fan. Make a note of which wire is connected to which terminal (1 of the fan wires has white lettering and 1 is just black)
Unplug both fan wire connects from circuit block to release the fan power cable.
Remove the fan mounting plate
Release fan blade clip by pressing fan against motor and unscrewing and remove fan blades
Unscrew motor from brackets - note alignment of motor on brackets
Mount new motor on brackets. Leave plug wire disconnected (replacement motor has a harnessed plug wire)
Connect new plug wire to the circuit block keeping wires connected to the proper terminals
Snake new plug wire behind condenser like the old wire was and run through cable bracket to the back right of the condenser
Plug wire harness into motor and re-mount fan mount plate
Reattach fan blade and secure using blade mount kit
Replace back panels
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jonathan from Plymouth, MA
- Parts Used:
- WP67005154
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
I put my frig. outside on my deck during a kitchen remodel and when I brought it back in a hooked up the water line again, I solenoid fill valve on the back of the unit leaked badly. I found a big crack in it and guessed it must have had a bit of water left in it when put outside in sub freezing, w
I searched in line for a replacement fill valve and easily found it on your site w/ excellent diagrams. I turned off the frig., & the part came out simply and logically first removing the 5 screws that hold it in w/ a nut driver. Then remove the supply water line and the other quick connect lines that feed the ice maker and the chilled water dispenser. Then, disconnect the two wire harnesses that clip off easily by hand. They feed the two relays in the valve and are color coded. Remove the valve and reverse the procedure to hook it back up. Note: a little water will come out of the lines so be ready w/ a small bowl and a dish towel. After installing the new part, it was necessary to "bleed" the water lines of air by drawing a few glasses of water from the water dispenser to get the system operating normally again. One tool, common sense, 30 minutes. Probably saved $150 + on a repair man plus parts markup. Thanks very much!!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- George from Glenwood, MN
- Parts Used:
- 833697
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Pliers
fan had stopped-freezer not performing etc.
simply removed old motor and replaced new. I'm over 82 and it was hard to get down and up to floor level!! One thing was a little puzeling -that was to insert the right screws which had a nitch in the end of the threds to keep it from loosening- I thought I was spoiling the threds cause I had to use a little pressure to start the screws and thought I had the wrong screws--they had sent several sets of them for different name brands- but II got it and everything seems to be allright - Could you tell me if I could purchase a replacement compressor and some refrigerent -the new kind. thank you, George Erlandson Only if my comp. goes out!!!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Andy from Hanover Park, IL
- Parts Used:
- WP67006006
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers, Socket set
The Ice Bucket broke and need it to be replaced.
First I removed the old ice bucket. It just slides right out. Then I removed two screw located right in front. After that all the parts come right off. Switch all the part from the old Ice Bucket to the new one. Reinserted the Ice Bucket and works like new.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Richard from West Warwick, RI
- Parts Used:
- W11396033
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
broken light switch
followed the instructions provided and that's it!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Kenneth from Newton Grove, NC
- Parts Used:
- W11396033
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Light switch rocker broke, disabling freezer internal light, water dispenser, and ice dispenser
Very simple. Matched female plugs with respective male color coded prong; pushed together then inserted unit in slot of freezer sidewall and rotated into position...job done.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- robert from central point, OR
- Parts Used:
- W10613606
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Fridge random humming
Unscrewed back of fridge and unplugged relay from compressor and plugged in the new one remember that the new one turns 180 degrees from existing switch.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Miriam from Canyon Country, CA
- Parts Used:
- W10613606
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
No cooling, compressor not running and was very hot
Plied off the relay switch with a screw driver. I could not pull it off by hand. Disconnected the wires to it and replaced with new part. Had problem getting the part back on and lining up the pins with the connector. I had to line up one pin and start at an angle and roll the part onto the contact pins.
I was impressed with the one day delivery without paying because it was shipped from a warehouse in California where the repair was made.
I was impressed with the one day delivery without paying because it was shipped from a warehouse in California where the repair was made.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Robert from Pennsylvania Furnace, PA
- Parts Used:
- D7824706Q
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers, Socket set
Ice maker leaked water
Overall, replacing the ice maker wasn't too bad but it wasn't nearly as easy for me as it seems to have been for some. In my case, the fridge was an Amana and the ice maker was mounted in such a way that disconnecting the power connector was difficult. The ice maker had to be completely dismounted before any access to the power connector was even possible. The short power cables made it very difficult to get the ice maker into a position where I had a good view of the power connector enabling me to see how to release it. The only other challenge was the cup that the water line goes into. The replacement ice maker did not come with the right cup - the instructions said to replace the provided one with the old one. No instructions for this procedure were provided and it looked to me like it might involve significant disassembly, something I wanted to avoid for fear of breaking a plastic part on the new ice maker (something I had already done when disassembling the old ice maker). So instead of replacing the cup, I modified the new one to match the old one. This involved removing a cutout on one side and covering a hole on the other. Installation of the new ice maker went fine and the water leak problem was fixed.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ronald from Marion, IL
- Parts Used:
- D7824706Q
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
didn't eject icecubes
R & R Icemaker Assembly. Took out 3 screws and unpluged Icemaker & replaced with new part. very easy and the service from PartSelect was fantastic.
Very Satisfied,
Ron Martin
Very Satisfied,
Ron Martin
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Clifford from Madison, IN
- Parts Used:
- WP67007098, WP12665101, WP12562701, W10857122
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Ice maker door broke allowing open hole to freezer
The ice maker panel on the freezer door detaches by removing two screens at the bottom of the panel behind the drip tray. My son held the panel while I removed three screws holding the ice chute cover. The ice chute door is attached to a spring loaded bracket. I only needed the actual door, but it was just as easy to replace the insulation and the seal. The seal was starting to show wear. I then replaced the ice chute cover and tested the ice maker. With everything working correctly, I reinstalled the panel in the door.
Was this instruction helpful to you?
Thank you for voting!