59657006600 Kenmore Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Thomas from Ruth, MI
- Parts Used:
- D7824706Q
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
My old icemaker lost some of the nonstick surface and the ice didn't want to come out
I unhooked the wire harness from the ref. and took out three screws and pulled the old unit out. I than changed a few parts from the old icemaker to the new and reattached the new ice maker to the ref. and plugged the wire back in. everything is working fine. No problems. Also I was very happy with the ordering process. Thank you!!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Gregg from Clive, IA
- Parts Used:
- WP67005959, WPD7749401
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers, Socket set
Ice Bucket cracked in back of unit
First, I removed the bucket and drained all the ice from it. Then I took the ice bucket out and lifted off the cover of it which exposed the teeth that grind up the ice. I then removed these in succession and placed on my table so I could make sure I put back together appropriately. Once I had the bucket with everything off of it, I replaced and threaded the auger back through it so I could attach the end cap to it. Once that was in place, I put the parts back on the way I took them off. It really was a painless process and saved a ton of money versus calling a repair person. Definitely will use the service again. Very prompt delivery as had the parts 2-3 days after ordered. Well done.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Linford from Cedarville, NJ
- Parts Used:
- D7824706Q
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Icemaker would not fill with water.
Removed screw under ice maker. Tilted ice maker up to remove unit from upper two screws. Disconnected plug at rear of freezer. Attached wiring harness, baler arm and cover from old to new ice maker. Reinstalled in reverse order. Had ice within one hour. Very easy fix.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Debbie from Bluffton, SC
- Parts Used:
- EDR4RXD1
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
The filter was clogged.
Replaced filter and the water started to flow like the Nile River and the ice maker came back to life.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Gary from Loreauville, LA
- Parts Used:
- WP67005959, WPD7749401
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Broken ice bucket and broken helix end cap.
I pulled off the plastic shield from the front of the ice bucket. This exposed the two screws that I needed to remove to disassemble the ice crusher mechanism. Once the screws were removed, I was able to remove the helix and replace the end cap that was broken and place it in the new ice bucket. If I would have known it was this easy, I would have changed this out a year ago, instead of doing without crushed ice through the door for so long. Thanks PartSelect. com! I am a customer for life!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Frederick from Hanover, MA
- Parts Used:
- WP67006506
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Power cord was cut
I removed the 5/16 inch hex head nuts holding the rear access panel where the power cord was connected. Once removed, I released the Molex plug and ground wire. I connected the new cord, screwed in the ground and installed the rear panel. Having the exact OEM part made the job quick and easy.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Bill from KINGSPORT, TN
- Parts Used:
- W10613606
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
Both compartments of the refrigerator were warm.
We came home from a long vacation to discover a warm refrigerator with its contents in various stages of decay.
Turning the freezer thermostat to its warmest setting then back to cold generated clicks, and after a few tries the compressor started and cooled the refrigerator to its normal cold temperatures. But… later the compressor again failed to start, and everything warmed back up again. With persistence and turning the thermostat up and down several times a day, we could keep the fridge cold.
It was time to order parts. We needed a new start relay and capacitor for the compressor. For our Amana ARB2214CW a start relay (WP12555902) and capacitor (WP65889-4) were listed on the first page of the Partselect parts list for my refrigerator. I ordered them, received them, removed the old capacitor and start relay (which rattled when shaken). and prepared to install my new parts. The new start relay did not match the old. The old start relay fit my wiring which had a single plug with two small female spade connectors in the plug. The new start relay required wiring with two separate female spade connectors; one the normal size and one larger. Phone calls to Partselect and to Westinghouse shed no light on the discrepancy. On the second page of the Partselect parts list was a combination of a start relay and a capacitor (W10613606) that matched my electrical connector. I could see the connection in the photograph. I ordered it and it fit. Easy peazy. That fixed the compressor start problem. Every time the freezer thermostat clicked on, the compressor started. Success.
But… from our troubleshooting we now had a thermometer the freezer, and it was obvious that the temperature difference between the cold point where the thermostat turned the compressor off and the warm point where the thermostat restarted the compressor was much too wide. In addition, the knob was hard to turn and was sticky as it turned. Oiling it fixed the sticky knob problem but not the wide temperature difference problem. I ordered a new freezer thermostat (WP67003000), received it, installed it, and all is now fine with my refrigerator. The new thermostat was physically a little different from the original, but it fit and worked.
I returned the first compressor start relay and capacitor and received a refund including the shipping charge.
Turning the freezer thermostat to its warmest setting then back to cold generated clicks, and after a few tries the compressor started and cooled the refrigerator to its normal cold temperatures. But… later the compressor again failed to start, and everything warmed back up again. With persistence and turning the thermostat up and down several times a day, we could keep the fridge cold.
It was time to order parts. We needed a new start relay and capacitor for the compressor. For our Amana ARB2214CW a start relay (WP12555902) and capacitor (WP65889-4) were listed on the first page of the Partselect parts list for my refrigerator. I ordered them, received them, removed the old capacitor and start relay (which rattled when shaken). and prepared to install my new parts. The new start relay did not match the old. The old start relay fit my wiring which had a single plug with two small female spade connectors in the plug. The new start relay required wiring with two separate female spade connectors; one the normal size and one larger. Phone calls to Partselect and to Westinghouse shed no light on the discrepancy. On the second page of the Partselect parts list was a combination of a start relay and a capacitor (W10613606) that matched my electrical connector. I could see the connection in the photograph. I ordered it and it fit. Easy peazy. That fixed the compressor start problem. Every time the freezer thermostat clicked on, the compressor started. Success.
But… from our troubleshooting we now had a thermometer the freezer, and it was obvious that the temperature difference between the cold point where the thermostat turned the compressor off and the warm point where the thermostat restarted the compressor was much too wide. In addition, the knob was hard to turn and was sticky as it turned. Oiling it fixed the sticky knob problem but not the wide temperature difference problem. I ordered a new freezer thermostat (WP67003000), received it, installed it, and all is now fine with my refrigerator. The new thermostat was physically a little different from the original, but it fit and worked.
I returned the first compressor start relay and capacitor and received a refund including the shipping charge.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Thomas from Cupertino, CA
- Parts Used:
- D7824706Q
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
The ice maker stopped making ice.
I did a few tests with the old ice maker and determined that it was the ice maker itself that was faulty. The replacement part I ordered exceeded my expectations in the time it took to get the part. I reused the arm, wire harness and clamps from the old icemaker. Then it was a simple install into the bottom freezer compartment, turning on the water supply and bingo...lots of ice cubes.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Amol from Missouri City, TX
- Parts Used:
- WP67005959, WPD7749401
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Ice maker started to jam
One day when i went to get ice our ice maker started to jam. When i took it out i noticed that the metal arm that turns was out of position and blocked due to the End cap being out of place. I then put it back in place and it happened again. The bucket cracked due to the pressure caused by the ice been . The only problem that i have now is that when i hit cubed ice, crushed ice comes out...and when i hit crushed ice, cubed ice comes out. The installation and swapping of parts wasw really easy. Partselect has great breakdown diagrams so if you get lost u can turn to them.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Geraldine from MUNDELEIN, IL
- Parts Used:
- W11395888
- Difficulty Level:
- Very Easy
- Total Repair Time:
- 15 - 30 mins
Did not need filter
Unscrew filter. Screw on filter bypass
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Karl from Lehi, UT
- Parts Used:
- WP67005154
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Hollow ice cubes or no ice, and trickle into water glass
Followed instructions and installed dual water valve. Did Not Solve Problem! ... Then replaced Water Filter. This fixed "water flow problem" and "no, or hollow" ice cubes.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Terry from WARMINSTER, PA
- Parts Used:
- W11396033
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Broken light switch
Watched video. Unplugged refrigerator and popped out switch. In plugged connector and pushed switch in place. Plugged in refrigerator and the light worked
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Robert from GOSHEN, IN
- Parts Used:
- W10156818
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Wife used vacuum cleaner and busted blade off fan
Instructions were great five minutes to remove and replace fan....Thank You............ saved big money
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from New Lenox, IL
- Parts Used:
- WP67005959
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Ice tray track was broken- hanging down with weight
Took ice tray out, removed plastic decorative cover, remove the four nuts under the cover, slide out the ice auger assembly as one piece. do not take auger assembly apart. I repaired mine once, difficult without a schematic picture, many parts, replaced everything back into the new ice bucket. Easy job!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Edward from Florance, MT
- Parts Used:
- WPD7749401
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Auger in the ice tray not turning
Removed ice container, replaced end cap that holds Auger shaft that connects to shaft that turns the Auger. End cap plastic nubs wear where it makes contact to the turning stub. Removing a few screws on the front of ice container allows the Auger shaft to slide forward and away from the end cap. Maneuver end cap from shaft, replace using same maneuver and that is it.
Pretty easy, even for a novice like me. A $6.00 end cap verses the whole assembly at around $70.00
I'm pleased.......
Pretty easy, even for a novice like me. A $6.00 end cap verses the whole assembly at around $70.00
I'm pleased.......
Was this instruction helpful to you?
Thank you for voting!