Customer:
Todd from Saint Paul, MN
Parts Used:
WR60X30349
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers, Screw drivers
Noisy freezer evaporator fan, bearings worn out
UNPLUG UNIT. Open freezer compartment, top door. You may want to let it warm up a bit before beginning work. Next remove single screw from small square plastic grate at top left back of freezer compartment with phillips screw driver. Remove green ground wire connection behind removed grate with nut driver. Next remove 2 screws at top of freezer compartment holding plastic air diffuser bracket in place and holding back panel. Remove metal back panel of freezer by pulling top towards you, then angle out of compartment. Evap. fan is now exposed. I inspected and removed fan by removing two screws with nutdriver on bracket behind fan blade. I inserted nutdriver (with long socket driver)between fan blades to screws on bracket behind blade - 1 each side. After these two screws are removed, pull fan and bracket assembly out from plenum. Remove wiring from motor and remove motor to workbench. Remove round metal clamp from fan hub with needle nose pliers and slide off fan blade from motor. Also remove bracket and rubber bushing. Disgard old motor. Inspect and clean blade. Replace if necessary. Reattach rubber bushing, bracket THEN fan blade to new motor. New fan has atleast one terminal in new location and I had to use one wire extension that came with kit. Route wire behind motor and plug in new wires to back of motor. Insert fan and bracket to plenum, hold in place with one hand while reattaching screws with nutdriver between fan blades. Once fan is in place and nuts secure, I tested operation by plugging unit back in to make sure new motor ran and fan spun freely. Reattach back panel, top diffuser bracket and small grate with 3 screws. Shut door, set temp. and wait 24 hours before loading freezer. Unit good as new!
8 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Eric from Rose Hill, KS
Parts Used:
WR57X10051
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Solenoid controlling the valve had stopped operating.
I first tested to make sure the solenoid was receiving power. Every time the arm on the ice maker cycled, the meter would go up to 120v for about 10-15 seconds, and then back to almost 0, so I knew the electical control and timer was working as it should.

The valve was easy to change - took about 20 minutes total (including pulling the fridge out and pushing it back in). I just turned the water off, removed the valve assembly from the fridge, and took all of the lines off of the old one. I then hooked up the supply line to the new valve assembly. The lines to the water and ice had compression fittings on them, but the new vavle has a "push-in" connector. So, I cut the old water and ice lines squarely, just past the fitting, then pushed them in firmly. Plugged the connectors in, re-attached the vavle assembly to the fridge, turned the water back on, and viola - I had ice in about an hour! Gravy! :)
8 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Hop from Houston, TX
Parts Used:
WR9X489
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
Refrigerator compartment warm, Freezer cold
This is a old 2000 side by side Kenmore frig bought from sears. left Freezer side was building up ice in the back, while right side was not cool at all. The Defrost Timer was behind the light panel on top in compartment side. Easily remove unit and unscrew things. Works like a champ.
7 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from Cumberland, MD
Parts Used:
WR60X114
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers
broken fan blade in the freezer compartment
Unplugged frige, removed top shelf, pulled broken fan blade off. Replaced with fan blade just purchased from PartSelect. Very simple repair. Orderd and recieved the right part.
7 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Charles from Edison, GA
Parts Used:
WR50X122
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Screw drivers
Refrigerator would begin to lose it's cool and we saw ice caking on the bacjk panel of the freezer section.
We had to empty the freezing section, remove the 4 screws that held the back panel and defrost the coils. Then with the diagram we got from the internet, we removed the defroster and easily installed the new one and put the back panel back on. We did find later that it was still icing over so I ordered the thermostat and we installed it today.
It too was easy to install. We spliced the wires and hooked the new thermostat to the old wires and reinstalled the back panel. Hopefully this will solve the problem for us now.
7 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Nicholas from Twinnsburg, OH
Parts Used:
WR72X242, WR72X240
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Right side drawer slides broken.
Total time to replace both slides was ten minutes. It took me longer to take the stuff off the shielf than it was to fix the slides!
6 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
James from Papillion, NE
Parts Used:
WR2X8702, WR2X8681
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Rubber actuator cover would not shutoff
Replaced the actuator rubber and back plate holder
11 of 21 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
H.K. from Seagoville, TX
Parts Used:
WR55X24065
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
compressor not starting
Refrigerator is not cooling. Light and fan working. Changed the capacitor.. Still not cooling. Back to discovery mode.It may be the timer
Certainly not PartSelect's fault. They have great service.
9 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Gerald from San Clemente, CA
Parts Used:
WR02X11330, WR17X2891
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Leaky water line to water dispenser
This part (plastic tubing) does not show up under my model of refrig...so I had to look thru the various water lines and pick the one that "looked" right. Luckily, this is the exact replacement part and works perfectly. I removed the lower back panel from the fridge, removed the bracket holding the water line connectors and pressed the outer ring of the coupler up until it released the old water line. I pushed in the new line, made sure it was snug with a gentle pull and ran the line under the fridge up to the existing coupler. I removed the old line from the existing coupler under the front left of the freezer door, and pushed in the new line. I did not need to use the new coupler. If my old line would not have been so brittle and cracked in several places, I could have just cut out the leaking portion and popped the new couple in to mend the line back together. Easy job and we can stop buying bottled water at the store now!
9 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Timothy from Orange Park, FL
Parts Used:
WR60X30349
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
stopped making ice
First I turned off the water supply. Then I removed the ice bin and the ice maker by removing 4 screws and 3 electrical connections. This allowed access to the evaporator fan which was not moving. To remove the evap fan I removed two screws that hold the fan bracket. The fan assembly now had to be pushed back and rotated to remove from hole. There are 3 electrical connections that have to be disconnected from the fan, one ground wire that also is connected to the fan bracket and 2 power connections. Installing the new fan was the reverse of the above except the power connections were in a different location and i had to use the extension wires provided with the new fan to have the length needed to make the connection.
7 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Dean from Park Ridge, NJ
Parts Used:
WR49X10183
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers
rusty ice maker
removed old parts and installed new. went smooth
7 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Eugene from Palm Springs, CA
Parts Used:
WR02X11330, WR17X2891
Difficulty Level:
Difficult
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Screw drivers
Water line was broken at the bottom of the freezer door.
There is no access to the inside of the door to replace the water line. I was able to insert a 1/4" drip line barbed connector into the old line at the base of the door and then connect that to a piece of the plastic tubing which I then connected back to the original water supply tubing with the 5/16" union. It took three attempts to get the tubing through the bottom hinge without a crimp in it. It's best to have a second person to hold the door while you "fish" the tubing through the hinge.
8 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Thomas from Dresden, OH
Parts Used:
WR9X489
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Refrigerator would not defrost
When it was discovered there was a cooling problem in the refrigerator, I went to parts select web site and went through the troubleshooting section. Then I tested the defrost timer and the defrost element as directed by the web site. I then found out doing this, that is was the defrost timer. I ordered the part online and it was delivered THE NEXT DAY! I removed the bottom panel of the fridge, removed the screw holding the old timer, removed the wires, and reversed the procedure to install the new one. It has been 1 week, and everything is working great. Thank you PartSelect.
I have since then recommended you to a relative who was having the same problem. Thanks again.
7 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert from Niceville, FL
Parts Used:
WR51X443
Difficulty Level:
Easy
Total Repair Time:
1- 2 hours
Tools:
Screw drivers
Fridge not cold & DE light flashing on status panel
Removed all the freezer shelves/trays. Removed screws top and bottom on back panel. Found coils completely frozen over. Used heat gun to completely melt all the ice. Found that the Defrost Heater actually includes a new Defrost Thermostat (unlike the service manual shows). Unplugged and unsrewed the old Defrost heater parts and unclipped the Defrost Thermostat. Installed the new parts, put everything back together, and returned the unneeded Defrost Thermostat for a refund. It's been working fine ever since.
6 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Peter from Marietta, GA
Parts Used:
WR02X11330, WR17X2891
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Wrench set
Refrigerator water dispenser tube (5/16"OD) broken at the back by valve
Tube was too short so I used the union to attach additional tubing to reach the valve at the lower rear of refrigerator
6 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!