Models > TFX30PRTAWW > Instructions

TFX30PRTAWW General Electric Refrigerator - Instructions

Jump to:

All Instructions for the TFX30PRTAWW
106 - 120 of 828
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
H T from South Haven, MI
Parts Used:
WR72X240, WR72X239
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Broken drawer slides.
Pretty much self explanatory.Removed drawer and anything on top of glass shelf.Remove two screws holding on slide.Replace with new slide.Repeat on other side.Replace shelf and drawer.
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Susan from Polson, MT
Parts Used:
WR62X107
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Ice trap door would not open
1. Unplug refrigerator or flip breaker to kill power to the refrigerator.
2. With hands, gently pull the bottom lip of the 3" X 11" face plate panel above the dispenser head.
3. Remove the 4 screws that are under the removed panel.
4. Tip the assemby down to reveal 2 plugs.
5. Gently pull the 2 plugs to disconnect.
6. Open the assembly to reveal the solenoid.
7. There are 3 screws at the base of the solenoid. The center screw attaches to the green ground wire.
8. Remove the three screws.
9. Observe: The bracket at the top of the solenoid unit tucks behind a 4th screw above the solenoid. You may need to loosen this screw to relesae the solenoid.
10.Unplug the yellow and red connector to the solenoid. It should not be totally free to remove.
11. Put the plunger into the solenoid. Note that the plunger has an opening to insert the white plastic trigger for the trap door. Make sure the trigger is inserted into this opening before reassembling.
12. Plug the yellow and red connector into the new solenoid.
13. Position the new solenoid to match the screw holes. The bracket at the top of the solenoid tucks under the 4th screw. Tighten as necessary.
14. Insert the green ground wire into the middle screw hole at the base of the solenoid and tighten.
15. Insert the two screws to either side of the ground wire and tighten.
16. Gently reconnect the two plugs.
17. Tip the assembly back into place making sure the trap door and hoses are lined up correctly.
18. Replace the 4 screws.
19. Snap the face plate back into place.
20. Turn on the power and give it a try!

I used other instructions provided by customers on the website. They were very useful.

This is the second time we replaced this unit. The first replacement failed within the one-year warranty period. I called customer service and they had a replacement part and refund for the previous part on its way immediately. Excellent service!
6 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Arthur from Camarillo, CA
Parts Used:
WR12X869
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
uncommon/unusual screws
Flat or philips screwdriver does not fit, Hex keys do not fit either. Had to buy a set of 6-pointed Torx keys to remove and re-install the existing screws. With the right tool it is an easy job.
6 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Sherrie from Midville, GA
Parts Used:
WR51X443
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers, Screw drivers
Refrigerator was warm and freezer was still cool. Removed back panel in freezer to find it frozen solid!! Thawed it out using a hair dryer, worked for a couple of days but it quickly was frozen yet again.
Removed back panel from freezer by removing a few screws.. Unplugged refrigerator as not get shocked.. removed old heaters and thermostat and replaced with new ones and it's been working perfectly!!
6 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ron from ORANGE, CA
Parts Used:
WR30X10093
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
Unit had stopped making ice
Ordered the icemaker replacement. unplugged the unit, followed the simple instructions and got it done in less than 30 minutes. It did take a LONG time to start making ice. But it's working now.
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
JOSEPH from SURFSIDE, FL
Parts Used:
WR02X11330, WR17X2891
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Cold water for door - leaked on floor
Pulled new tubing to the tank and put a union about 8 inches down from tank to new tubing. Great repair. Parts not readily available locally.
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Chip from Mandeville, LA
Parts Used:
WR30X10093
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
broken auger in the bucket assembly.
I ordered the wrong part, the ice maker assembly, because your diagram was not marked properly. I returned the part and you credited my account. Thanks. Ordered the new bucket. It worked fine. Now I have ice and crushed Ice whenever I want. Thanks.

p.s. I didnt use any tools, but to satisfy you I select nut driver.
6 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Blair from Evanston, WY
Parts Used:
WR55X129
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Ice Despenser wouldn't dispence ice
All i had to do was pop off the front trim, remove 4 small screws, unplug two plugs and replace the board.

It took me a grand total of 9 minutes to get the job done.

Way cheaper than having a repair man come to the house twice, once to diagnose, and once to replace the board he would have ordered and marked up.
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
john from Fairfax, VA
Parts Used:
WR72X241, WR72X239
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Plastic drawer side rails broke. The rails and the drawers seem very flimsy for the cost of the refrigerator.
Very simple fix. Unscrewed broken drawer rails and replaced with the new. No big deal. But again, these seem very flimsy for this model of refrigerator. they should use metal drawer rails with rollers to better accomodate the wieght of produce in the drawers.
6 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Chris from Waterville, KS
Parts Used:
WR72X242, WR72X241
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
broken drawer rail (cheap plastic poorly engineered)
remove screws from broken rails and install new rails with screws.
7 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Bruce from Mobile, AL
Parts Used:
WR2X4550
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Drive cup broke due to ice cube jamming it
Remove three screws insert part; manually checked out drive and waited for ice to buildup and it worked like new.
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Charles from Keller, TX
Parts Used:
WR30X10093
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Ice Maker would not fill.
Was concerned that new icemaker was quite a bit different than the one we were replacing. Called GE to confirm it was correct.

Went ahead and installed the unit, using the supplied electric cable adapter.

A little difficult to deal with the extra cable, but everything worked OK and it's making ice normally.
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
George from Brandywine, MD
Parts Used:
WR57X10051
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
no Ice
Turned off The water supply. Removed the back panel corner(nut driver). Removed valve (nut driver) and water supply inlet line. Cut the old outlet lines at the valve (new lines are push in) disconnected electrical lines, Reinstalled inlet line and electrical lines. Reinstalled valve and back panel. Turned on the water. Ice maker filled with water and a short time later I had ice. Easy job.
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mark from Albuquerque, NM
Parts Used:
WR72X239
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
slide rail broke causing shelf to fall
repair was simple removed glass shelf and removed the two screws holding rail in place. I was really amazed at the quick service that I had receiced, I ordered two of the same part and they had the instructions to send back the additional part in my email the next day. Thanks for your help.
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Darlene from New Harmony, IN
Parts Used:
WR51X443
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
freezer coils froze over &refrigerator wasn't cold.
I had to take out 4 screws that held the element in place. remove the old element and disconnected one wire connection. put the new element back on and connected the wire .
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the TFX30PRTAWW