Models > TPX24BIBABB > Instructions

TPX24BIBABB General Electric Refrigerator - Instructions

Jump to:

All Instructions for the TPX24BIBABB
46 - 60 of 143
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
David from Mechanicsville, MD
Parts Used:
WR57X10051
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Wrench set
Leaking Inlet Water Valve
Very quick and easy repair. Took off cover to access valve using standardr screw driver. After shutting off water supply to valve disconnected copper water supply line. Used a large towel to catch any residual water in line. Removed two water lines on valve use plies if more than hand tight to loosen. Removed screw holding valve in place, removed valve and disconnected wires (be sure power to frig is off least you get a shock. Reverse proceedure to install new valve. new valve has simple push in connections for plastic water lines. Install two electrical adpaters and electric lines. Mount valve with screw, connect copper water line. Turn water back on and check for leaks. Turn power on and check for proper water running at dispenser. Again check for any leaks. No leaks, install cover and you are done.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Henderson from Holladay, TN
Parts Used:
WR57X10051
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers
After the ice dumped, the tray would overfull and run over into the freezer
The operation is very simple on this valve. I disconnected the water lines and wires.
Then two I removed the two screws attaching
valve to the ref.box.
The reinstall is just the opposite from removal.
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from PARKVILLE, MO
Parts Used:
WR02X10098
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Socket set
Had a 'ticking' sound
Separately (from a different site) purchased new compressor fan and motor. I purchased the grommets here because the other site listed the grommets as temporarily out of stock. I did watch one of the videos on PartSelect about the grommet replacement. Repair was pretty simple, biggest challenge was getting to the screw on the far side of the motor. Removed the two screws holding the fan motor into place. Removed motor and blade. Reinstalled with new fan blade, new grommet and new motor.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from Columbia, MO
Parts Used:
WR57X10051
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Wrench (Adjustable)
Body case seal gone bad on water valve
Easy. First, unplug the fridge.

1)Shut off then disconnect water line.

2)Remove water valve mount screw.

3)Disconnect electrical plugs and snip water lines (square cut lines for new valve).

4)Simply insert and seat water lines into their respective places on the new valve. Using adapters as needed, reconnect electrical plugs.

5)Mount valve and reconnect water line.

6)Turn on water supply and check for leaks. Possible leaks: water line or not fully seated lines to the new valve.

7)Restore power and enjoy :o)
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Louis from LEAGUE CITY, TX
Parts Used:
40A15
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
Change bulb
Easy
3 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Karen from Gainesville, FL
Parts Used:
WR57X10051
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Wrench (Adjustable)
ice maker stopped working
I unplugged the refrigerator and shut off the water. I removed the back of the frig where the inlet valve is located. I removed the old nuts and cut the plastic water line on the ends. I shoved them into the new fittings. I then turned on the water and plugged in the frig. I could hear the water pumping into the ice maker. I screwed the inlet and back of refrigerator in place.
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Gary from Groesbeck, TX
Parts Used:
WR57X10051
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Wrench (Adjustable)
water over filling ice tray and leaking into ice tray and freezing
Followed the directions on the web site and did everything that was instructed to do and had no problems with installing the new dual water Valve. Has been in now for a week and no more over filling or freezing water in the storage box. Lots of clean ice, now!
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mark from Dumfries, VA
Parts Used:
WR57X10051
Difficulty Level:
Easy
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Screw drivers, Wrench (Adjustable)
Water Valve Leaking
Removed lower cover screws removed cover removed copper water feed tubing connector unplugged wire connectors pulled out plastic water line connector and water lines removed water valve assembly installed water lines installed wire connectors secured valve assembly reinstalled copper water line turned on water valve checked for leaks reinstalled lower rear cover
2 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
kathleen from red oak, TX
Parts Used:
WR57X10051
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers, Wrench set
leaking water valve
I used a screwdriver to remove, then replace, the screw that holds in the valve. I used pliers to pull the refer water line out of the old valve. I just used my hands to reinstall the line. I used and open box wrench to remove and reattach the main water line. Nothing blocked access to the valve and it was very easy to remove the old one and install the new one.
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
George from Cun City Center, FL
Parts Used:
WR17X3909
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
The shield light had burned the shield
I hung the new shield on the two inside pegs that were already there.
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
James from Somerset, KY
Parts Used:
WR57X10051
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Socket set, Wrench (Adjustable)
water wouldn't shut off
replaced solenoid
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jerry from Poquoson, VA
Parts Used:
WR57X10051
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
My icemaker was leaking down the back wall of the freezer (side-by-side unit) building a huge ice flow that grew into the path of the circulation fan.
After turning the water off, I removed the two screws holding the cover on the lower back of the freezer. I disconnected the copper water supply line from the valve. I then removed the screw holding the valve in place and removed it from the freezer. I removed the two wires from the valve and placed them on the new valve (after inserting the clip inserts to match the new size tabs).I pulled the two plastic water lines out of the valve and inserted them into the new valve. I put the new valve in place and replaced the screw. Total time less than 15 minutes. Much easier to fix, than to identify the problem. The collective wisdom of the internet strikes again! Thanks to all.
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
George from Old Bethpage, NY
Parts Used:
WR57X10051
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Wrench (Adjustable)
Leaky valve
Removed three screws, water input line, two water output lines. The new valve had push on fittings instead of screw on, so had to cut the old fittings off. Connecte input and output lines Replaced three screws holding valve in place. Turned water back on. Finished.
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Johnathan from Gilbert, AZ
Parts Used:
WR57X10051
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Wrench (Adjustable)
Ice maker overflowing. Valve stuck open
The valve I got was slightly bent up. I spent the first 10 minutes or so bending it back with my muscles. once that was done, I took off the backing of the fridge with the screwdriver, undid the single bolt holding the valve on, and unplugged it all (fridge was already unplugged). Just like everyone says, the tubing connecter is different, so I took off the old compression fittings, and pushed the tubes in. THen I hooked up the wiring... I realized that that the wiring adapter was needed but there wasn't enough room for it as is.. so I have to bend the tabs so the wiring would angle down. Everything has worked perfect since... I got Ice and no leaks! woo hoo!
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Chester from Chambersburg, PA
Parts Used:
WR57X10051
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Wrench (Adjustable)
Valve leaked water and needed to be replaced
First I removed the incoming water line from the valve. I then removed the screw that hold the valve in place. Then I pulled the element out about 3 inches and disconnected the two connector wires. Next I cut the plastic hoses from the old valve.
To install the new valve, I inserted the two plastic hoses into the new valve. (hoses are different diameters so it is next to impossible to insert them incorrectly.) I replaced the electrical connectors (This was the only glitch since the one connector on the refrigerator is larger then the pins on the new valve, A little electrical tape held the connector in place.) I then tightened the screw that holds the valve on the refirgerator and reconnected the household water to line to the valve.
The entire job took less time then it has taken me to type the procedure.
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the TPX24BIBABB