TFJ28PFBAAA General Electric Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- joselito from riverview, FL
- Parts Used:
- WR17X11653
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Ice Building Up In The Ice Dispenser Chute
Under the control panel there are three small holes. Insert ballpen or small flat screw driver on both outer holes to push a tab lock that holds the control panel in place. Then pull out control panel and three set of wires will be exposed and disconnect wire connectors (connectors have different sizes so you wont get confused in reconnecting). Unscrew four screws on each corner that holds the ice dispenser assembly (a part where you push your glass against to dispense ice or water. The flapper is exposed and easy to replace.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from Chapel Hill, NC
- Parts Used:
- WR57X10051
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers
Leaking valve
The valve was leaking from the core and not the in/out tubes. The valve is easy to get to and very easy to replace. When replacing the water in/outs you cut them off the old valve and then slip them on the new valve. 5 to 10 minute job.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Chester from Chambersburg, PA
- Parts Used:
- WR57X10051
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Wrench (Adjustable)
Valve leaked water and needed to be replaced
First I removed the incoming water line from the valve. I then removed the screw that hold the valve in place. Then I pulled the element out about 3 inches and disconnected the two connector wires. Next I cut the plastic hoses from the old valve.
To install the new valve, I inserted the two plastic hoses into the new valve. (hoses are different diameters so it is next to impossible to insert them incorrectly.) I replaced the electrical connectors (This was the only glitch since the one connector on the refrigerator is larger then the pins on the new valve, A little electrical tape held the connector in place.) I then tightened the screw that holds the valve on the refirgerator and reconnected the household water to line to the valve.
The entire job took less time then it has taken me to type the procedure.
To install the new valve, I inserted the two plastic hoses into the new valve. (hoses are different diameters so it is next to impossible to insert them incorrectly.) I replaced the electrical connectors (This was the only glitch since the one connector on the refrigerator is larger then the pins on the new valve, A little electrical tape held the connector in place.) I then tightened the screw that holds the valve on the refirgerator and reconnected the household water to line to the valve.
The entire job took less time then it has taken me to type the procedure.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jerry from Poquoson, VA
- Parts Used:
- WR57X10051
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
My icemaker was leaking down the back wall of the freezer (side-by-side unit) building a huge ice flow that grew into the path of the circulation fan.
After turning the water off, I removed the two screws holding the cover on the lower back of the freezer. I disconnected the copper water supply line from the valve. I then removed the screw holding the valve in place and removed it from the freezer. I removed the two wires from the valve and placed them on the new valve (after inserting the clip inserts to match the new size tabs).I pulled the two plastic water lines out of the valve and inserted them into the new valve. I put the new valve in place and replaced the screw. Total time less than 15 minutes. Much easier to fix, than to identify the problem. The collective wisdom of the internet strikes again! Thanks to all.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- ROBERT from STOW, OH
- Parts Used:
- WR57X10051
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers, Wrench set
no ice
Removed cardboard cover from back of refrigerator with nutdriver. Removed old pump and reconnected water lines and electrical. reinstalled pump.It did take about 5-10 minutes for the pump to refill ice tray.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mary from Port Monmouth, NJ
- Parts Used:
- WR57X10051, WR17X4358
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Wrench set
dispenser reservior was leaking water outlet vale also developed a leak
shut the water supply to the refridgerator unscrewed valve mount removed removed valve supply line with half inch wrench loosened and removed plastic nuts on outlet by hand unplugged both valve actuator cables. loosened two phillips screws from reservior removed inlet and outlet hoses replaced with new parts very simple repair
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- George from HOSCHTON, GA
- Parts Used:
- WR17X11653
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Frost collected in the ice dispenser shute clogging it
Replace the flapper and this solved it. The video provided was excellent and allowed me to do this repair myself.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- kathleen from red oak, TX
- Parts Used:
- WR57X10051
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers, Wrench set
leaking water valve
I used a screwdriver to remove, then replace, the screw that holds in the valve. I used pliers to pull the refer water line out of the old valve. I just used my hands to reinstall the line. I used and open box wrench to remove and reattach the main water line. Nothing blocked access to the valve and it was very easy to remove the old one and install the new one.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Johnathan from Gilbert, AZ
- Parts Used:
- WR57X10051
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Wrench (Adjustable)
Ice maker overflowing. Valve stuck open
The valve I got was slightly bent up. I spent the first 10 minutes or so bending it back with my muscles. once that was done, I took off the backing of the fridge with the screwdriver, undid the single bolt holding the valve on, and unplugged it all (fridge was already unplugged). Just like everyone says, the tubing connecter is different, so I took off the old compression fittings, and pushed the tubes in. THen I hooked up the wiring... I realized that that the wiring adapter was needed but there wasn't enough room for it as is.. so I have to bend the tabs so the wiring would angle down. Everything has worked perfect since... I got Ice and no leaks! woo hoo!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mark from Dumfries, VA
- Parts Used:
- WR57X10051
- Difficulty Level:
- Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Screw drivers, Wrench (Adjustable)
Water Valve Leaking
Removed lower cover screws removed cover removed copper water feed tubing connector unplugged wire connectors pulled out plastic water line connector and water lines removed water valve assembly installed water lines installed wire connectors secured valve assembly reinstalled copper water line turned on water valve checked for leaks reinstalled lower rear cover
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Gary from Groesbeck, TX
- Parts Used:
- WR57X10051
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Wrench (Adjustable)
water over filling ice tray and leaking into ice tray and freezing
Followed the directions on the web site and did everything that was instructed to do and had no problems with installing the new dual water Valve. Has been in now for a week and no more over filling or freezing water in the storage box. Lots of clean ice, now!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- George from Old Bethpage, NY
- Parts Used:
- WR57X10051
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Wrench (Adjustable)
Leaky valve
Removed three screws, water input line, two water output lines. The new valve had push on fittings instead of screw on, so had to cut the old fittings off. Connecte input and output lines Replaced three screws holding valve in place. Turned water back on. Finished.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jabe from Little Torch Key, FL
- Parts Used:
- WR17X11653
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
In-Door Dispenser Didn't Work And Leaked Water
1. Use skewer to press plastic tabs under control panel, 2. Remove control panel and unplug solenoid, 3. Unscrew dispenser assembly and solenoid screws, 4. Press in tabs on lamp and remove assembly - unplug, 5. Replace lamp assembly, 6. Replace solenoid assembly and fasten screws, 7. Replace flapper. 8. Replace other parts in reverse order.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Larry from Castlewood, VA
- Parts Used:
- WR02X11330, WR17X2891
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Wrench (Adjustable)
Water tubing lines runs very close the compressor. Over time the heat caused the line to become brittle. Result was broken line and lots of water under the unit.
Cut the line inside the regiferator behind the bin and used the tube union to attach new 5/16" tubing to run to the solenoid valve assy in the back of the refigerator. Location of the valve assy makes connecting very difficult. But was able to complete repairs.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Karen from Gainesville, FL
- Parts Used:
- WR57X10051
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Wrench (Adjustable)
ice maker stopped working
I unplugged the refrigerator and shut off the water. I removed the back of the frig where the inlet valve is located. I removed the old nuts and cut the plastic water line on the ends. I shoved them into the new fittings. I then turned on the water and plugged in the frig. I could hear the water pumping into the ice maker. I screwed the inlet and back of refrigerator in place.
Was this instruction helpful to you?
Thank you for voting!