36358772892 Kenmore Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- GARY from PARRISH, FL
- Parts Used:
- WR30X10093
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers, Wrench set
Failed Icemaker
Shut off power to the refrige. Removed old icemaker, using large hammer. Installed new unit.
Was this instruction helpful to you?
Thank you for voting!
Freezer would ice up and refrigerator stop cooling
First i unpluged the power then cleaned everything out of freezer and removed all the drawers and racks them removed the 2 screws at bottem of freezerand removed panel then removed 4 screws on the bulbs and unpluged the wire and took off the sensor and replaced with new one put everthing back. Then on the top of refigerator side on the top behind the adjuster is the defrost timer pulled handle out and off removed plastic shield and removed 2 screws and unplug the timer and change it then put everything back and pluged back in and everything worked in a few minutes
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Theresa from Rochester, MI
- Parts Used:
- WR57X10051
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Screw drivers, Wrench (Adjustable)
low flowing water (not just a drip) from refrigerator ice maker
The icemaker's valve is easy to inspect and test. First, gently pull the refrigerator away from the wall, and unplug it. Turn off the water supply to the icemaker by closing the shut-off valve in the copper waterline leading to the valve. Use a screwdriver or nutdriver to remove the rear lower access panel from the refrigerator's back.
Next, remove the fill tubing from the water valve. Use a wrench to loosen the flare nut on the brass fitting on the inlet side of the valve (above). Place a container or towel under the valve to catch the small amount of water that will spill from the valve and tubing.
Now use a screwdriver or a nutdriver to remove the screw holding the valve's mounting bracket to the refrigerator cabinet. Pull the valve out of the compartment and remove the tube (or tubes if both water dispenser & ice maker) on the valve's outlet. If plastic tubes don't come out with pliers and assuming there is enough extra tubing, then cut the plastic tubing with a even straight cut edge razor. Then, remove the solenoid's electrical contacts.
Push the plastic water and ice tubes int he appropriate holes in the new valve outlet, reconnect solenoids and remount new water valve.
Before installing the back panel on the refrigerator cabinet, test run the icemaker. Look for leaks, and tighten any leaky connections. If necessary, use Teflon tape or a similar product to ensure tight connections. Discard the first ice cubes that are produced because they are likely to have sediment in them.
Next, remove the fill tubing from the water valve. Use a wrench to loosen the flare nut on the brass fitting on the inlet side of the valve (above). Place a container or towel under the valve to catch the small amount of water that will spill from the valve and tubing.
Now use a screwdriver or a nutdriver to remove the screw holding the valve's mounting bracket to the refrigerator cabinet. Pull the valve out of the compartment and remove the tube (or tubes if both water dispenser & ice maker) on the valve's outlet. If plastic tubes don't come out with pliers and assuming there is enough extra tubing, then cut the plastic tubing with a even straight cut edge razor. Then, remove the solenoid's electrical contacts.
Push the plastic water and ice tubes int he appropriate holes in the new valve outlet, reconnect solenoids and remount new water valve.
Before installing the back panel on the refrigerator cabinet, test run the icemaker. Look for leaks, and tighten any leaky connections. If necessary, use Teflon tape or a similar product to ensure tight connections. Discard the first ice cubes that are produced because they are likely to have sediment in them.
Was this instruction helpful to you?
Thank you for voting!
Both Slides Were Broken
I removed the shelf, unscrewed the slide rails and replaced them with new ones. I replaced the shelf, put the food back in and I was done. Thanks, john bowers
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- george from palmetto, FL
- Parts Used:
- WR23X366
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Wouldn't dispense ice
First pried off front panel, then removed 4 screws that hold dispensing unit in place, then rotated top of dispensing unit out, then pulled off electrical connector, then removed screw that holds switch in place and removed switch. Installed new switch by reversing above procedure. Only thing switch wasn't the problem. No ice problem was resolved later by replacing control printed circuit board which is located in the same area.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jania from Novato, CA
- Parts Used:
- WR23X37285
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
The refrigirator light would not come on.
Poped out with screwdriver the old swithch and unplugged the two wires. Plugged in the wires to the new swithch and pushed it back in the hole where the old switch was before.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- William from Chesapeake, VA
- Parts Used:
- WR17X4312
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
dirty ice from rusty auger
Removed old bucket/auger assy from frig. Removed 4 + screws from front cover. Put front cover on new bucket/auger assy. Reinstalled in frig.....done. now have clean ice.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Gary from Glendale, AZ
- Parts Used:
- WR30X10093
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Replace ice maker
New ice maker only used 2 screws and the old one had 3. This was no problem. The old ice maker had already been removed. Just loosen the 3 screws and unplug the cord to ice maker. Only problem with ice maker was with the cord, which I had to use the supplied adapter. It was too long and in the way when reinstalling the ice bin. The ice bin had a small notch area on the bottom left. I used a plastic tie to bundle the cord into the notch. Carefully placed ice bin and no problem. The first part I received was damaged and was replaced 2 days later by a brand new part. Customer service charged for the replacement part but said they would credit my charge card within 2 to 3 weeks for the damaged part. Its been a week and if they follow thru like the said I woild give Part Select 5 Stars for service and Parts.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- William from Moorestown, NJ
- Parts Used:
- WR60X10008
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- More than 2 hours
- Tools:
- Nutdriver, Screw drivers
Refrig. Side not cooling enough
Replaced several things: evaporator fan motor, defrost heater element & defrost timer. The motor was the key problem but did the other repairs because they are common failures and are easy to replace and are not that expensive. Changing the motor was tedious because of tight access to it. Took about 2 hrs for me. Fan is working properly but not have a problem with water to ice maker not shutting off. I'm researching that problem. (I replace the water valve 2 hrs ago. That was a simple task - took 15 mins.)
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from Mebane, NC
- Parts Used:
- WR29X5171
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Screw drivers
Ice maker would not make ice..
1) I removed the icemaker and placed on work table.
2) I pried the front plastic cover from the control box to expose the front base.
3) I removed the three mounting screws from the base (it is not necessary to remove the screw in the plastic gear) and removed the front base. This exposed the back base
4) Using an ohmmeter, I was able to isolate a bad contact on one of the three microswitches in the control box (the one that was mounted to the back base). Replacing this microswitch solved the problem.
2) I pried the front plastic cover from the control box to expose the front base.
3) I removed the three mounting screws from the base (it is not necessary to remove the screw in the plastic gear) and removed the front base. This exposed the back base
4) Using an ohmmeter, I was able to isolate a bad contact on one of the three microswitches in the control box (the one that was mounted to the back base). Replacing this microswitch solved the problem.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Rene from Bronx, NY
- Parts Used:
- WR9X489
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Frig would stop working every so often. Lots of food got spoiled.
Got part overnight. Unscrewed cover plate at top of regerator compartment, disconnected old part, connected new part. Screwed back plate. Voila!
I saved a bunch of money!
I saved a bunch of money!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Tracy from Yuba City, CA
- Parts Used:
- WR30X10093
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Stripper on the icemaker broke into pieces.
Remove the two nuts holding the top of the unit to the side of the freezer using a 1/4 in nutdriver. Pull the unit out and unplug it from the back of the freezer. Remove all pieces of the broken stripper. The replacement part fits onto a peg on the back of the icemaker and into a slot. Bend into place and slide into position.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Gregory from Yucca Valley, CA
- Parts Used:
- WR17X2891, WR02X11330
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Broken water line near solonoid to feed drinking water
bought an push in, in line connector and a new 5/16 plastic hose. I just replaces 2 feet of plastic hose from the selonid up an splices the hose using the connector. Worked perfect.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Christopher from Madison Heights, MI
- Parts Used:
- WR9X489
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Refrigerator to warm freezer ok
The comments from customers experiences gave me the confidence that the defrost timer was the problem since the compressor was still working and it went just as they all said, four 1/4' hex head screws and I had access to the old timer, unplugged the old ,plugged in the new and put the four screws back in. Nothing happened so after a while I looked a bit harder at the accessable part of the timer after intallation and saw what looked like a dial. I turned the dialclockwise and immediatly the compressor turned on. I have not found any information as to how much or little to turn this dial which obviously is an adjustable cycle setting so I just turned it all the way, so far everything is working alright.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- CHRIS from LAGUNA NIGUEL, CA
- Parts Used:
- WR60X187
- Difficulty Level:
- Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Pliers, Screw drivers
Compressor overheating - Fridge not Cooling
Condensor Fan not turning. I thought it would be an easy fix. I thought I could pull off the shroud and fan assy - no joy. Too many copper pipes and lots of tubing in the way. It took 90 minutes to remove and 30 minutes to install. The BIG hint here is to loosen the shoud, pull it back as far as you can and then remove the nut that holds the fan blade in place. THEN you can remove the motor. Get the new motor back into the shroud, get the blade back on and then tighten the shroud back up.
Was this instruction helpful to you?
Thank you for voting!