Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
Phil from GREENFIELD, IN
Parts Used:
W11395888
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers
Remove the water filter to install the bypass cap
Lower the filter bottom housing to gain access to the filter. Unscrew the filter and install the bypass cap. Secure the lower filter housing to the top assembly.
11 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Roderick from NEWTOWN, PA
Parts Used:
WP2300868
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
Leaking water tube connector/union
Received the union I ordered, then discovered that the tubes were different sizes, so I had the wrong part. I had read elsewhere that it was necessary to trim the two ends of the tubes with a box cutter to stop the leaks - I did this, and the leaking stopped. I was then able to go to a local hardware store and get a 5/16 to 1/4 union and replace it. The leaking is stopped, and the water supply in the door is now working like new. No problem with partselect, but I did buy a caliper so that I can check tube diameters if I ever have a similar problem! This is a great site to find instructions - well worth the time to search!
10 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
jeff from brownsburg, IN
Parts Used:
WP67005959, WPD7749401
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
the helix end cap broke and the ice maker wouldn't dispence ice
Well it was very simple. I just pulled out the ice cube bucket , removed a few screws from the front of the bucket, pulled the front panel off, replaced the helix end cap too the auger, put all of it back together into a new ice bucket, screwed the front panel back on , than lined up the auger to line up with motor shaft of the freezer motor and what do you know I HAD ICE. My family was happy and i did this for under thirty dollars. A repairman would of cost more than three times that just to look at problem and would of cost more for the parts and the second trip to fix it. Thanks you for making it easy to find the part and for the quick delivery of the parts.
12 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jeffrey from Elburn, IL
Parts Used:
WP67001503
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Large Crisper Drawer Cracked And Broke So I Could No Longer Push The Crisper Drawer In And Out
I removed the old crisper drawer, took all the fruits and veggies and put them into the new crisper drawer, and then slid the new crisper into position. If was the exact size and part I needed.
8 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Garry from Anderson, IN
Parts Used:
12002193
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers
My ice maker was driping water on the ice cubes
It was really pretty simple. You get to the back of the frig, open a panel and the valve is right there. The instructions where clear on what to do, even though the new valve was different water line connections. It was spelled out what to do. Works great and all the parts supply places would have to ordered it anyway, so I saved $ and got the valve in 30 hours to boot. Thanks
9 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Richard from West Warwick, RI
Parts Used:
W11396033
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
broken light switch
followed the instructions provided and that's it!
12 of 20 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Brenda from Spokane Valley, WA
Parts Used:
EDR4RXD1
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Replace water filter
pop open, unscrew quarter turn, screw new one in quarter turn, pop shut. duh
13 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Kenneth from Newton Grove, NC
Parts Used:
W11396033
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Light switch rocker broke, disabling freezer internal light, water dispenser, and ice dispenser
Very simple. Matched female plugs with respective male color coded prong; pushed together then inserted unit in slot of freezer sidewall and rotated into position...job done.
10 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
robert from central point, OR
Parts Used:
W10613606
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Fridge random humming
Unscrewed back of fridge and unplugged relay from compressor and plugged in the new one remember that the new one turns 180 degrees from existing switch.
9 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Miriam from Canyon Country, CA
Parts Used:
W10613606
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
No cooling, compressor not running and was very hot
Plied off the relay switch with a screw driver. I could not pull it off by hand. Disconnected the wires to it and replaced with new part. Had problem getting the part back on and lining up the pins with the connector. I had to line up one pin and start at an angle and roll the part onto the contact pins.
I was impressed with the one day delivery without paying because it was shipped from a warehouse in California where the repair was made.
8 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
brandt from sycamore, GA
Parts Used:
W11227239
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Fridge was not cooling and staying around 50 degrees. Freezer was cooling normally.
Looked on web to see problems with same model. Recieved new board, unplugged fridge,took off cover inside fridge top left,took old board out, unplugged wires from old board and plugged new board in, installed cover and plugged fridge into wall outlet.
9 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Clifford from Madison, IN
Parts Used:
WP67007098, WP12665101, WP12562701, W10857122
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Ice maker door broke allowing open hole to freezer
The ice maker panel on the freezer door detaches by removing two screens at the bottom of the panel behind the drip tray. My son held the panel while I removed three screws holding the ice chute cover. The ice chute door is attached to a spring loaded bracket. I only needed the actual door, but it was just as easy to replace the insulation and the seal. The seal was starting to show wear. I then replaced the ice chute cover and tested the ice maker. With everything working correctly, I reinstalled the panel in the door.
9 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Fidel from Forest, MS
Parts Used:
WPW10128551
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Refrigerator wouldn't cool
First I removed the six screws from the cover. I then disconnected the two wires and pulled the small motor out with its base and removed two screws that hold it in place. I then changed the old one for the new one and set it back in its place. I then set the cover back and turned it on. I was happy again.
10 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Emi from Arlington, VA
Parts Used:
W11395888
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
no water when under sink water filter installed
I called the installer of my filter unit and he told me that often, thhe fridge filter is the problem. Like magic it worked
11 of 19 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Debbie from Bluffton, SC
Parts Used:
EDR4RXD1
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
The filter was clogged.
Replaced filter and the water started to flow like the Nile River and the ice maker came back to life.
10 of 16 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!