Customer:
Robert from Orlando, FL
Parts Used:
WR55X129
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
ice being made but would not dispense
Easy repair. Snapped cover off control panel. Removed 4 phillips head screws on control board assembly. Removed (2) connectors from assembly and pulled out defective unit. Installed new control board in reverse order. Everything now working. Very fast and easy repair once you have the part.
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Charles from Keller, TX
Parts Used:
WR30X10093
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Ice Maker would not fill.
Was concerned that new icemaker was quite a bit different than the one we were replacing. Called GE to confirm it was correct.

Went ahead and installed the unit, using the supplied electric cable adapter.

A little difficult to deal with the extra cable, but everything worked OK and it's making ice normally.
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
George from Brandywine, MD
Parts Used:
WR57X10051
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
no Ice
Turned off The water supply. Removed the back panel corner(nut driver). Removed valve (nut driver) and water supply inlet line. Cut the old outlet lines at the valve (new lines are push in) disconnected electrical lines, Reinstalled inlet line and electrical lines. Reinstalled valve and back panel. Turned on the water. Ice maker filled with water and a short time later I had ice. Easy job.
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Henry from Rockville, MD
Parts Used:
WR17X4312
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
I had a smell from the ice and bad taste
I removed the 4 screws from the cover and replaced the auger and ice bucket assembly. Extremely simple and I was amazed how easy it was.
5 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Cathy from San Antonio, TX
Parts Used:
WR17X3489
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Broken light shield in freezer
SUPER easy repair, taking about 5 minutes. After taking out the ice bin, I removed one small phillip's head screw, put the light shield in place, and tightened the screw.
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from Randle, WA
Parts Used:
WR32X1492
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
The vegetable pan was broken from closing the door on it too hard when still open
I just slide the new one in place, using exsisting sliders. I had to remove the old grab handle from old pan and snap it into place on new pan.
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Charles from Rose Bud, AR
Parts Used:
WR50X122
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Wrench set
Refrigerat
rerfrigator side not cooling After determinating that the defrost timer was running I turned it to defrost and watched tosee if frost started to melt. When it didn't I checked the heater with ohmeter, checked OK, so the only other component in the defrost system is the thermostat. Then just a matter of cutting and splicing wires and snapping the new thermost in place
5 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Barbara from Medical Lake, WA
Parts Used:
WR17X4312
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Ice maker would not dispense ice cubes
Removed the face plate (4 screws) on the ice bucket/auger and put it on the new unit.
6 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Dean from Folsom, CA
Parts Used:
WR30X10093
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
The Icemaker failed to make ice
I pulled the refrigerator away from the wall and turned off the water to the refrigerator and unplugged it from the wall. After removing the icebucket from the freezer I located the mounting screws, loosened them, unplugged the electrical connection below the icemaker and carefully removed it from the freezer. I unpacked the replacement icemaker, matched it against the original and attached the electrical connection adapter. Using the slots provided on the new icemaker I placed it over the mounting screws after aligning the water inlet pipe properly. I tightened the mounting screws while maintaining the icemaker in a level position. I plugged in the electrical connector. Then I replaced the icebucket, plugged in the refigerator back into the 110VAC outlet, turned on the water and repositioned the refrigerator in it's normal position.
8 of 16 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Alan from Jonestown, TX
Parts Used:
WR55X129
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Pliers, Screw drivers
Water / Crushed Ice / Cubed Ice Switch Broken
Unplugged and shut off water. Popped off the face plate from below. Unscrewed 4 screws. Pulled out control board assembly. Pulled off two wire connectors. Unscrewed 2 screws to remove control board fastener. Replaced control board and reversed steps to assemble. When plugged in fridge, the switch was stuck on, so unplugged. Had to remove the rubber push plate and reassemble making sure the plastic lever was set properly in the control board. Reassembled and it worked properly.
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
robert from WOONSOCKET, RI
Parts Used:
WR51X10055
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers
Freezer coils were iced up,was not cold enough,suspected the heater was the culprit
I had looked at videos on you tube,it looked simple enough. I mostly do my own repairs so I gave it a shot. the job went well,if you do not fix things around the house don't try to do the repair,find a handyman in your neighborhood to help you out,cheaper than calling a refrigeration man. It is not that hard to do.
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
MARIO from SAN RAMON, CA
Parts Used:
WR72X253
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Pliers, Screw drivers
Both right side Drawer Slide Rail braken
Very easy. The top rail was replaced with the new part. The lower rail was found broken upon removal of drawers, and not having a second new rail, I made an aluminum inser for the screws to hold fast and attached it with fiberglass tape and CA .
I realy was impress with your fast service and knowledge of interchangable parts from other bran makers. We got an GE brand part instead of a Kenmore but It worked perfect.
Thanks for your NEXT DAY delivery. .
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Daniel from St George, UT
Parts Used:
WR51X10055
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
Refrigerator temp went to 60 degrees
Freezer section defroster heater was inoperative.
turned off the refrigerator by turning the right knob in top rear refrigerator to 0.

Used hose on a vacuum sweeper blower side to feed warm air into the bottom rear section. Removed the top plastic panel behind the ice maker to allow air flow to exit through the fan to defrost the freezer coils.

Placed a flat oven pan into the area beside the vacuum hose and sponged up the melted frost water. After 30 minutes, water ceased to drain.

Removed freezer shelves, and 5 screws on rear freezer wall. It took about 2 minutes to remove the heater & braw assembly at the bottom of the coils. 2 screws have to be removed and wires just clip off and back on again. Replaced the 2 screws.

Replace rear coil wall cover and turn on the refrigerator to 5 to 7 and replace cover and shelves.
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Charles from Inman, SC
Parts Used:
WR17X11653, WR2X8663
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Frost building up in ice shoot air leaking around door recess assembly
First disconnect power and turn off water supply.Removes the cover that indicates water and ice settings,removed 4 screws that held the switch assembly on,unplugged wiring harness (left solenoid wires connected.removed screw holding arm that closes door and removed assembly.Covered hole with duct tape ordered parts (which came very quickly turned water and power back on.When new parts came actuator arm was different on door put old one on door and reassembled in reverse order
7 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Christopher from Acworth, GA
Parts Used:
WR62X107
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Solenoid was hanging creating an awful noise when dispensing ice
Unplugged the refrigerator. Removed the panel to the ice/water dispenser. Removed the cover that displays ice type/water and light. Removed the 4 screws holding the cover. Unplugged the wiring harness to the cover which allowed easy access to the two electrical connections to the solenoid.
Removed the three bottem screws holding the solenoid in place. Loosened the top screw ( do not remove completely) and the solenoid slide down. Removed the solenoid arm that hangs on door latch.
Install hang solenoid arm on door latch; slide solenoid up under top screw. Install bottom 3 screws to hold solenoid in place then tighten top screw. Reattach electrical lines to solenoid then plug wiring harness back into cover. Install 4 screws holding panel in place. Re-install two remaining covers.
4 of 5 people found this instruction helpful.