John from Randle, WA
Parts Used:
WR32X1492
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
The vegetable pan was broken from closing the door on it too hard when still open
I just slide the new one in place, using exsisting sliders. I had to remove the old grab handle from old pan and snap it into place on new pan.
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Kenneth from Sweet Home, OR
Parts Used:
WR51X10101
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
evaporator coils iced up causing no cooling in freezer or fridge.
First I disconnected the Power from the unit. Pulled out the freezer drawers and the ice machine used a 1/4 inch nut driver and removed the sheet metal from the back of the freezer exposing the evaporator coils. I defrosted the coils. Then I removed the two screws holding the defrost heater braket assembly and removed the two electrical connections from it. I then installed the new heater put everything back together(reverse of installation)and it works like a brand new fridge and freezer.
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Scot from Fort Collins, CO
Parts Used:
WR17X4358
Difficulty Level:
Difficult
Total Repair Time:
More than 2 hours
Tools:
Nutdriver, Screw drivers, Wrench set
Tubing from vavle to reservoir had been degraded by compressor heat and had cracked, leaking water when door water dispenser was used.
- Disconnect the valve assembly and remove electrical connection to water dispenser valve to prevent accidental water discharge

- Disconnect tubing from valve assembly, remove and keep compression nut.

-Disconnect tubing from junction to door tube remove and keep compression nut

-Remove screws used to mount reservoir, pull tubing into main refrigerator compartment and remove old reservoir and tubing.

- Note that one of the tubes on the new reservoir is 2' too short.

- Go to hardware store to purchase 5/16" universal tubing compression junction.

- Install reservoir and feed tubing through holes in main refrigerator compartment.

- Route tubing through woven tubing protectors and clips.

- Trim tubing to length and install in valve using old compression nut.

- Splice the piece of tubing trimmed from supply side of reservoir to the outlet side tube using the fitting purchased from the hardware store.

- Connect end of tubing to existing junction using old compression nut.

- Re-connect wires to valve solonoid and test for leaks.

- Re-install valve assembly to refrigerator frame.
6 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Scott from South Lake Tahoe, CA
Parts Used:
WR17X4358
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Screw drivers
Dispenser Water Reservoir failed seem
This was a very easy fix. I cut the water lines at the reservoir, coupled the old lines to the new lines with two plastic barbed fittings used for outdoor drip irrigation. All I had to do was pull the old lines out and the new lines followed. Easy as pie!
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert from San Marcos, CA
Parts Used:
WR30X10093
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
no ice made
Performed self test.turned off ice maker switch four 5 minutes.Then turn on switch,within 10 seconds,pushed ice paddle 3 times,with 1 second in between each push.Push all the way back and release. Ice maker should cycle and squirt water. My ice maker did neither.I unplugged cord from fridge.So i replaced the ice maker.After a couple of screws had ice again !
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Peter from Ashford, CT
Parts Used:
WR57X10051
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers
Cold water dispencing was becoming slower and volume of ice was becoming less.
Shut water supply off, removed power plug from wall and removed electrical connector from valve. Unscrewed two plastic nuts which retained lines to old valve. Remove old valve and reinstalled new valve with one screw. Removed inserts from end of lines. (These inserts keep lines from deforming.). Trimmed and chamfered ends of lines reinstalled inserts and installed lines to new valve. Turned on watter, checked for leaks turned power on inserted glass for water received good flow. Ice maker did not receive water. Due to low flow of water to ice tray because of low flow with old valve, ice built up in flexable water delivery tube that goes from back of refrigator to ice tray. Removed tube ran under warm water removed ice blockage reinstall tube all working excelent. This iceing problem took about anouther 15 to 25 min to correct.
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
HUAHUI from NEW HYDE PARK, NY
Parts Used:
WR51X10101
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Refrigerator cannot generate cool air
I bought the GE Refrigerator about 4 years ago for about $1500. The defrost Heater failed about one year ago. Then I called local repair guy, he replaced the Defrost Heater and charged me about $250. Now it happened again. I think we should try it to fix it by myself. I found the parts from partselect.com, it costs me $50 with 2-3 days shipping. After it replaced, it works fine again.

Note: Symtom: cannot make cool air, Frozen area with frost on the wall. Regeriator "leaking water" on floor since iced food started to melt...

Solution: open the cover of the wall inside of frozen zone, use hot water to defrost it gradually. removed the failed Defrost Heater and replaced it with new one.

Note: after you defrost the area inside of the wall, your refrigerator will work normally without the Defrost heater without any issue about week while you are waiting for the parts coming.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Frank from Florham Park, NJ
Parts Used:
WR57X10051
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Wrench set
Water was not running out of dispenser but the ice cube maker was working
Well I Googled the problem to the dual inlet water valve. Luckily I found PartSelect for the correct part and the installation was simple. I now have both the cubes and water working properly from the dispense.
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Daniel from CRIDERSVILLE, OH
Parts Used:
WR51X10031
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Automatic Defroster was not working and it caused the unit to not stay cool.
After removing the 4 screws from the inside back panel of the freezer and setting a small heater with fan, on a small metal step ladder for about twenty minutes to defrost the freezer coils, it was a snap to remove the two small screws holding the burned out heater harness defrost assembly, and unplugging the wire harnesses to replace the burnt unit with a new one. Actual hands on time was about 5 minutes. Difficulty level, well... my wife did it and she is not mechanically inclined.
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from Elk Grove, CA
Parts Used:
WR13X10020
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Socket set
cam closing washer broken
I propped up the door with 2x4 and shims to be level with the freezer door. Then removed the 2 screws holding the hinge to the main unit. Then removed the 2 screws holding the cam washer to the door.
Replacement was the reverse of disassembly. Be sure to tighten screws almost tight until both pieces are located correctly then fully tighten. Lift up refrigerator door slightly to remove shims and wood block.
I did the replacement myself but was nervous that the door would fall off the block and shims. I recommend having another person hold the door closed during the process.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Rudolph from Arroyo Grande, CA
Parts Used:
WR51X10101
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Screw drivers
evap coil freezing up every 2 weeks
removed 2 - 1/4" screws and 2 phillip screws to take off the evap cover, then 2 phillip srews to take out the defrost heater assembly, replaced and put everything back together. no problem.
I GOT THE PART SO FAST THAT I WAS SURPRISED TO SEE IT THERE!
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jerry from Hurst, TX
Parts Used:
WR57X10051
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Pliers
My wife called me at work and said the refrigerator was "peeing" on the floor.
When I got home I pulled the refrigerator away from the floor, checked all the water lines for leak evidence, and then took the back panel off to check everything behind. The water valve was leaking at the hose insert locations. I turned off the water, spent less than 5 minutes disassembling the valve from the rerfrigerator, and got online to buy another one. The part arrived several days before expected, and it took me less time to install the new part than it did to take the old one out. Now all I have to do is repair the floor damage I caused when pulling out the refirgerator!
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Laurence from Dearborn, MI
Parts Used:
WR13X10020
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Screw drivers
Door would not close properly
I emptied everything from door compartments.I removed the top cover of the door pivot with a phillips screwdriver. I removed the two screws that that hold the pivot bracket with a 8 mm socket. Lift the door off the bottom pivot bracket. Remove the old bottom pivot bracket with an 8mm socket and replace it with the new cam bushings.You must replace both bushings on the bottom of the door and on the bracket that mounts to the base of the body of the refrigerator. Reinstall the door and screws .The doors should be level with each other if they are installed properly.If not check the freezer door .The bushings may be worn on that door also.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Lynn from MOUNTAIN HOME, ID
Parts Used:
WR30X10093
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Made ice would not eject from ice holder bin
removed broken bin , slid new ice bin in closed door. I bought the complete part.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Karen from SAN ANTONIO, TX
Parts Used:
WR30X10093
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Ice maker filled too full and ice froze in the basket and a piece was broke on the icemaker itself.f
My son did it , and showed me what he did when he was finished.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!