TFXC24ELP General Electric Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Eileen from Coto de Caza, CA
- Parts Used:
- WR23X37285
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers
switchlight on my refrigerator was not working
I found instructions on the web about how to do this repair, so I ordered the part with confidence. But the instructions simply said "pull out the old switchlight". That was actually somewhat difficult as the clip on the side intended to hold the part in was stubborn. I eventually used a utility to slice off the clip. From that point, it was just a matter of plugging in the new switchlight , which was very simple.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- George from Harrisburg, PA
- Parts Used:
- WR2X7491, WR2X4540, WR13X10020
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Socket set
door hinge shims worn out
The PartSelect web site was able to direct me right to my GE double door frig using the model number. I called in to order the parts that were worn out with some operator assistance finding out all parts were available to my surprise. I received the parts in just a few days. I blocked the door up with some scrap lumber allowing me to take the old hinge off being careful to watch where the old parts were located. I reassembled the new hinge. It all took about 30 minutes and about $40. If I would have called a service repairman it would have easily cost me $100 and with a lot less satisfaction. This is the second time I have used PartSelect with similar results.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Dilver from Milton, KY
- Parts Used:
- WR9X489, WR13X10020
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Pliers, Screw drivers
refridgerater side warming, freezer warming
First I diagnosed the problem being a defrost timer as the symtoms are the same as the heater elements. I installed the timer and it worked great for about a week until the frost build up on the evaporator became too much again and then the symtoms returned. I then checked the heater elements and found that both were bad PLUS two clips to the elements were corroded. I then ordered the 2 heater elements. There is more than 1 heater element. Make sure you measure the length of each and then use the graph picture with "Parts Select" on the new ones before you order. There is about a 2" in length difference. Also one comes in a kit with thermostat and wires. Wrong for me. I really wanted that unit as I needed the harness for the bad terminals but it was the wrong heaters and it also came with a new thermostat. Luckly I did not order that one but did order a new thermostat to make sure I did not have to go through this ordeal again. When the parts came I had already replaced the terminals and was ready to go when FedX came. Just make sure you check your heaters before just buying the defrost timer as it may keep you from going back to redo your repair. Just doing your home work before ordering may save you much time in your repair. "PARTS SELECT" was one day on both orders and I just ordered standard shipping. They are great to do business with.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- kenneth from west chicago, IL
- Parts Used:
- WR17X2062
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
Ice-maker grinding faceplate heavily rusted causing rusty ice
Disassembled ice-maker, noting what screws went where, what direction ice release control arm pointed, and noting how the control arm spring was mounted. The door assembly comes off first followed by the circular assembly that houses the ice door and last grinding arms. It is quite easy see how it comes apart as you look at the screws. Remove the screw holding the back end of the control arm and note the spring position. The control arm needs to be turned to line up notches to pull it thru a faceplate hole while rotating the arm about the "U" that is on the outside of the faceplate in the door housing. There is a retaining clip holding the rotating impeller to remove to complete the dis-assembly. Use vinegar to clean rust out of bin and other parts around the faceplate. Assemble the unit in the reverse order to complete the job.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jeff from Venice, FL
- Parts Used:
- WR2X4901
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
Door Not Closing Tightly + Staying Open
Turned off water to ref , removed bottom kick plate , got a towel and disconnected the water line plastic fitting and un screwed the (2) tube clamps un screwed the coupling and ((carefully )) slid out the tube from the compression ferrels ! ( Be careful and do not break or distort them + remember exactly the order they are removed ! Slid the protector spring shroud from the plastic tube , took ogg the top hinge cover then remover the top hinge . Carefully lifted the door off feering the plastic tube through the bottom hinge with my foot ! Got the door off removed the bottom hinge + put the new on on, then removed the door cam which was broken on the bottom of the door , lifted the door up and carefully fed the water line through the new bottom hinge . Attached the top hinge and reassembled the rest same as I had dissambled it . Turned on water ( checked for leaks ) ! All working 100% a-ok ! This company is the best ! Ordered the part at 1 pm and had the part at 2 pm the following day many thanks : )
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from San Marino, CA
- Parts Used:
- WR2X4901
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Screw drivers, Socket set
Door wouldn't close properly
First we removed the door. Then we had to hammer the old part off including the old rivot. We fould a screw that fit and put this piece on. We held the door in place and screwed the hinge on the main unit.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from Newport Beach, CA
- Parts Used:
- WR2X4901
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers, Socket set
The fresh food door on the refrigerator would not stay closed
First I took everything out of the fresh food door, then I removed the top hinge cover using a philips head screwdriver, and a nutdriver for the two screws holding the upper hinge. Lifted the door off the bottom pin, and placed it on the floor. Then took off the bottom hinge and used the Dremel tool to grind off the rivet holding the broken door cam on the bottom hinge. Used a nut and bolt to hold the new cam in place, and put the lower hinge back on. Then replaced the other cam on the bottom of the door itself, using the nutdriver. (Be sure to buy two cams, and have the bolt and nut to replace the rivet). Reinstalled the bottom hinge, put the door on, replaced the top hinge, and presto! Works great! Thanks to the others on this site for their stories - really helped make it an easy and quick repair!
Was this instruction helpful to you?
Thank you for voting!
Door would not close all of the way
I don't know exact details. My husband replaced parts while I held the door.
We removed connections for the door on the bottom (propped up on books). We installed the new cam, the old one cracked and broke, and the new shim and the door is now even with the top of the fridge. It was not before, and the seal near the bottom of the fridge was not solid. Now it is. It was very easy.
We removed connections for the door on the bottom (propped up on books). We installed the new cam, the old one cracked and broke, and the new shim and the door is now even with the top of the fridge. It was not before, and the seal near the bottom of the fridge was not solid. Now it is. It was very easy.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Larry from Renton, WA
- Parts Used:
- WR13X10020
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Socket set
Closing cam disintegrated
Removed everything from the refrigerator door. Removed the screw holding the cover over the top hinge. Removed the two (8mm) bolts holding the top hinge to the refrigator. Removed the door. Removed the plastic grill/cover and the two (8mm) bolts from the lower hinge assembly. Installed the new hinge assembly. Replaced the closing cam (included in the hinge assembly kit) on the bottom of the door. Put the door back on the lower hinge. Installed the upper hinge. Adjusted the door and tightened the bolts on the upper hinge, and replaced the hinge cover. Done!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Donald from Lauderhill, FL
- Parts Used:
- WR13X10020
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers
Door would drop down when opened
Removed the door by removing the top hinge and lifting it off the broken bottom hinge/cam assembly. Removed the broken hinge/cam assembly found out why the cam broke the doorstop was bent so I had to order the doorstop also. The ordering of the parts was so easy. They shipped them on Monday and they arrived the next day. I will use Parts Select again
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Terry from Grand Forks, ND
- Parts Used:
- WR57X10051
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Water valve cracked
Pulled out the fridge - unpluged. Water supply was already closed.
Then took off the cardboard cover in the back. Used a nut driver to remove 1 screw. Disconnected water lines and elec. connects.
Water lines slid into quick connects - connected electrical and mounted. Opened water suply needle valve.
Pluged in fridge did a quick test for leaks. Done in 5min.
Then took off the cardboard cover in the back. Used a nut driver to remove 1 screw. Disconnected water lines and elec. connects.
Water lines slid into quick connects - connected electrical and mounted. Opened water suply needle valve.
Pluged in fridge did a quick test for leaks. Done in 5min.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- michael from CENTRALIA, IL
- Parts Used:
- WR23X37285, WR2X9391
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
light kept blinking on and off never same way
turn breaker off first then use thin blade screwdriver and plastic pry bar to remove light socket and switch there was plenty of wire so work was easy to install at both ends
Was this instruction helpful to you?
Thank you for voting!
ice bucket and auger assembly did not work
Found your web site and bought a couple of replacement parts from you guys and reaaembled unit. Its now working. Only issue I had was in the reassembly of the auger unit, wasn't quite sure of the blades etc. and the proper order Saw the sketch on your site and figured it out from that. Will visit you guys again when I need a part. Good delivery and timely. Thanks and regards Gil
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Max from TUCSON, AZ
- Parts Used:
- WR13X10020
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Socket set
lower door hinge worn
I replaced both lower hinges without removing the doors. First a couple of observations. The hinge kit consists of two parts; the lower part (bolted to the case) consists of an “L” bracket with a plastic cam, and the upper plastic cam (attached to the door). For some reason the upper cam is available as a separate part . If both cams are plastic both are worn out. Don’t bother ordering the individual cam. If one hinge is worn out the other probably isn’t far behind. Consider replacing both at the same time. Examine the door check. It is an inverted “T” shaped bracket bolted to the door that also holds the door cam. The crossbar of the T are metal tabs that check the door swing. Way too fragile IMO. On mine the refrigerator side was cracked and broke off when I removed it. Since the stops are the same right and left. I just swapped them when I replaced the hinges. Saved $22. Replacing the hinges without removing the doors. {Warning if this technique goes wrong you will be stuck with a loaded door you can’t open.} Remove the vent grill. Stack three 2x4’s along the bottom of both doors ( 26” is about right ). Shim the door(s) up to compensate for the cam wear. About 1/8”) Use a 5/16 socket to remove the hinge from the case. Pay attention to placement of the shims and spacers. Then remove the door cam and stop bracket. Install the new door cam. Leave the screws a little loose. Replace the lower hinge and tighten the screws. Do both sides. Then carefully remove the shims and 2x4’s. Finish tightening the door hinge screws. Check the door swing. I used this technique twice. One to replace the refrigerator side hinge, then again to replace the freezer side hinge and swap the door checks. There were no problems and I saved the hassle of unloading and removing the doors.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Marnie from Denver, CO
- Parts Used:
- WR60X114
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers
a fan blade broken causing it to make a loud noise
we took off the old one and replaced it.
Was this instruction helpful to you?
Thank you for voting!