Customer:
joe from spartanburg, SC
Parts Used:
WR23X31507
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Light would not work when I opened door.
I lifted the old switch with a flat screwdriver, attached wires, and popped into place. Saved 80 bucks for a repair call.
23 of 29 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from Cary, NC
Parts Used:
WR02X13425, WR02X10779
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Socket set
Fridge Door would not close "automagically"
I had to remove the fridge door (side by side), which took approximately 10min (most of which was retrieving the right size socket wrench from the garage). With the door removed, I could replace the broken door closing cam and door stop... with 4 screws. Not much to it. Had the door mounted back on in another 5min and that was it. :)
24 of 33 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Richard from The Villages, FL
Parts Used:
WR17X11168
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers, Socket set
Tube feeding ice maker leaking.
Moved refrigerator out from wall. On the back of the refrigerator at the bottom there is a metal plate. Removed this plate with a socket wrench to expose where the end of the tube pluged in. The grommet securing the tube, white on my unit, had to be pushed up to release the old tube. I pushed the new tube into where the old one was and it self secured the tube. The other end of the grommet I pushed through the hole feeding the ice maker,first pushing out the broked part with a screwdriver,and securing that end with the attached sticky tape already attached to the grommet. I cleaned the area around the hole with alcohol before attaching the grommet.Replaced metal plate and done. No leaks.
23 of 31 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Carlos from Whittier, CA
Parts Used:
WR17X11168
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
water leaking from grommet tube assembly at back of fridge
After thawing out freezer pushed water supply tube out from inside freezer diconneted the supply line from the valve assembly by pushing in the bushing with my finger and inserting the new line. Sadly that wasn't the problem!For anyone with the same symptoms of ice building up on your ice maker, to the point where it clogged the water supply line and started leaking from the grommet assembly. The problem is the valve not closing when the ice maker does not need any water. so I ordered a new valve and hopefully that will fix my problem.
22 of 30 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Charles from Elizabethtown, KY
Parts Used:
WR30X35285
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Ice maker quit working
Looked up possible causes on the internet, did the trouble shooting: off wait 15 seconds, then on, hit the ice level switch 3 times. No cycling - order a new ice maker. Had already checked water supply line and water filter. Screws in difficult positions to use standard screwdrivers or if you have medium size hands to remove plastic guards. After that was easy to replace whole unit. Cut plastic guards to be able to get at mounting screws for next time. Designers definitely need to think about consumer repairing of items rather than disposable major items not built to last 10+ years.
28 of 51 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
justin from brownsville, OH
Parts Used:
WR49X10091
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
evertthing in frige was freezing
went online to an appliance repair site and found out that this model has problems with the damper malfunctioning. went to partselect and ordered what I needed and it arrived in two days. to replace the damper you just remove the light at the top of the frige and the cover around it . the damper assembly only has 2 screws and is easy to remove.
19 of 24 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Richard from Chandler, AZ
Parts Used:
WR02X45206
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Socket set
Cracked Housing Mount - water leak
Turned off the water. Removed the maintenance cover plate on the back of the refrigerator and disconnected the tubing. Removed the tubing cover plate on back of refrigerator. Removed two screws from filter hosing mount on the inside of the refrigerator and pulled the old tubing out. Simply inserted the new tubing and mounted the housing and reconnected the tubing using plumber’s pipe compound. Then re-installed the cover plates on the back of the refrigerator, installed the filter and turned on the water. It was a very easy install.
19 of 25 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
James from Jacksonville, FL
Parts Used:
WR11X10010
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Freezer door lever broke
Unscrew the two mounting screws for the plastic vent plate on the bottom of the SS unit and take the remove the vent. Next, slide the end of the lever through the square hole in the bottom bracket and attach the hook end of the lever to one end of the lever spring. Pull on the other end of the lever spring and slip it over the spring mount finger that is a part of the bottom bracket frame. Finally,reattach the plastic vent plate with the 2 mounting screws. Total repair time was less than 15 minutes.
18 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
kevin from summerville, SC
Parts Used:
WR02X45206
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers, Screw drivers
low water flow from in door water dispenser
after changing the water filter and having no improvement. I went to the next part of the system. Turned off the water supply. I removed the bottom cover in the back of the refrigerator. unscrewed the nuts on the water supply hose from the main supply and the one going back into the fridge. moved to the inside of fridge and unscrewed two screws holding the filter mount and pulled the tubing through. Reversed my steps and the water flow was great . Thanks
17 of 20 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Michael from Meridian, MS
Parts Used:
WR17X11168
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Wrench set
Icemaker supply hose leaking at freezer entrance
I did it the way you recommended except rather than removing the existing tube from the water valve at the bottom of the fridge I cut the existing and new tubes and then spliced the new tube to the old tube. I already had the splicer nut so it was quicker and easier. By the way, shipping was very quick and you prices and your website are excellent!
18 of 24 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Heather from Pennington, NJ
Parts Used:
WR51X10101
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
loss of refrigeration
After mopping up the floor - the whole freezer that was iced up melted - that's how I found out about the problem...

Disconnected the power, emptied the freezer, removed the shelves. Under the ice maker was the light cover - I removed that first, then the two screws holding the back panel in place - The light panel was covering the top screw.

With the screws removed, I pulled out the back panel - which needs to be jiggled around a bit to get it past the shelf brackets.

With the cover off, I could see the mostly de-iced coil at the back of the unit. The defrost heater was visible at the bottom of the coil frame. To remove the bracket/heater, I removed the two cross head screws (one on each side) holding the bracket to the coil frame. I then twisted the side tabs of the bracket assembly and pulled the entire bracket/heater/wiring from the coil frame.

With better access tot he bracket/heater I was able to disconnect the wires. I grabbed the new bracket/heater, reattached the wires and pushed the bracket/heater back onto the coil frame and closed the side tabs firmly attaching the bracket to the frame. I then screwed the tabs back onto the frame.

Replaced the back panel, screwed it in place. Put back the light cover and then the shelves. Turned the appliance back on and left it for a few hours - before checking to see if there was any drop in temperature. There was, so after 24 hours or so I reloaded all the food...

NOTE: I was certain that the heater had failed! When I pulled the OLD one out it was obviously burned out - the glass tube was blackened and pieces of the element could be seen in the bottom of the tube.
15 of 17 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Sherry from Auburn Hills, MI
Parts Used:
WR02X11330
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
My 13 yr grandson assisted me on this
We couldn't get the other connector loose from one end of the tubing so he said just cut it and so we did and attached the connector. I now have water again in my fridge and took the sticky note down "don't use the water" as it had leaked for a year...... Thanks!
15 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jamison from Heltonville, IN
Parts Used:
WR57X33326
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Iced up Freezer compartment in SxS
So I replaced a burnt out defrost heater; replaced the thermostat for good measure and STILL the freezer compartment was freezing up. WHY didn't I look more closely at the ice making system sooner!!?? Thought about it for a while and decided that it had to be that the solenoid in the water valve was NOT shutting off water flow to ice maker (overflowing the icemaker and running over & down interior of freezer compartment making an icberg).

Took off about 4-5 backcover screws with one size nut driver. Moved to a size larger driver to remove 1 screw holding on the water valve. And what some people don't realize is that you can push in the connectors (push them down) and THEN pull the water lines out as long as you're careful and someone hasn't already tugged on the waterlines with some force. You don't have to cut the lines off at the valve. Put the water lines in the new valve and put one screw back in it; then 4-5 backcover screws and you're done!!! At most 15 minutes...that is if you want to clean the condensor unit located behind the backcover (on the newer models within the last 4-6 years).

EASY!!! Do it yourself and save a BUNCH of money. If you're getting a flooded freezer compartment or icebergs created in there then check whenever you hear the icemaker drawing in water and see if water is running down the interior.....problem solved!
15 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Sheila from Robeline, LA
Parts Used:
WR02X11941, WR62X23154
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Wrench (Adjustable)
ice auger drive stripped out, solenoid burned out
removed ice tray, removed drive unit. removed solenoid and replaced, screwed on auger drive. reinstalled drive assembly. replaced ice tray. job done.
21 of 38 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Kimberly from Suwanee, GA
Parts Used:
WR17X11440
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
Water collecting under vegetable tray
Very easy to install. Simply follow the hoses to the end. One ends under the freezer door in front. The other requires you to take the back panel off the fridge - then its right there. There is a blue valve where it connects. Pull back on the white ring at the top of the blue valve and the old tube will release. Then you can just pull the old water tank out and thread the new tubes through. Connect the same way and you disconnected.
13 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!