- Customer:
- Mark A. from Port Byron, IL
- Parts Used:
- WR60X10258
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- More than 2 hours
- Tools:
- Nutdriver, Pliers
Bad Ice Auger Motor
Things I learned...remove only the two far left screws and one far right screw from the ice auger motor mounting plate. Disconnect both wiring harness connectors. With the assembly removed from the freezer, you'll need to get the motor seperated from the drive mechanism (fork). This was the most difficult part of the repair. The reason is that the fork (which is reverse threaded) cannot be unthreaded independantly of the motor shaft (ie. they both turn together). Locking pliers on the shaft only stripped metal from the shaft and did not supply enough torque to remove the fork. The way I finally did it was to take the old motor partially apart, then lock the gear case (keeping the shaft from rotating) with the motor's own splined internal rotor shaft. Once I finally got the fork apart from the motor shaft, swapping out motors was simple. You'll need to put the old plastic glove on the new motor to keep it dry. Also, the replacement motor I got from partselect.com did not come with threaded mounting bolt holes. Therefore, I had to use slightly larger self tapping screws I got from the hardware store. I also used locking washers as the assembly is subject to vibration.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- randy from vancouver, WA
- Parts Used:
- WR02X11330, WR57X33326
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers, Wrench set
Water Leaking @ Quick Releases (Blue and White)
Had previously replace the plastic Water Tank, but when installing it I didn't realize how the quick connects worked. Instead of simply pushing inward in the direction of the blue part of the disconnect, I had pulled out the white ring on the outside of the disconnects. This ruined the inside connections and caused them to leak thus requiring these repairs. Had I known that I wouldnt have bought these parts too. Just Always REMEMBER to push in outside white ring on the quick disconnect and as you push it in pull out the hose when you remove it. To put the hose back in, just push it back in without pushing on ring this time at all and it will lock in place, and shouldn't be leaking. I had to run water into a glass to test if it was leaking, otherwise the line had no water pressure.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Joe from Succasunna, NJ
- Parts Used:
- WR24X20456
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Gasket wasn't sealing
Replaced gasket. No tools requires. Just pull the old one out and press new one in channel with hands. TIP: heat the new one slightly with a hair dryer or a heat gun on low. Makes it more flexible
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ed from Chesterfield, VA
- Parts Used:
- WR57X33326, WR17X11168
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
ice maker tube would freeze up
installed new double water outlet and tube assembly and it fixed the promblem. I think the water valve was leaking by causing the tube to freeze up inside.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Robert from Sandston, VA
- Parts Used:
- WR02X45206
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers, Socket set
water and ice maker stopped working
Removed the cover on the bottom of the rear of the fridge and the top left of the fridge where the tubbes exit.. Then just simply disconnect the tube coming from the fridge and the supply line. Next go inside the fridge, remove the cover of the filter mount, and remove the 2 screws securing the filter mount in place. Now pull the tubes through the opening and reinstall in reverse order.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- nancy from silsbee, TX
- Parts Used:
- WR2X9391
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
bad light socket
unplugged refrigerator. removed light bulb from old socket. unsnapped old light socket and pulled it out just enough to diconnect the electrical plug that plugs into the socket . discarded the old socket and plugged in new socket. snapped in new socket into refrigerator. i watched how to do this simple procedure on you tube and decided to do it myself. easy easy easy
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Thomas from Waynesboro, VA
- Parts Used:
- WR17X11440
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Cold water reservoir tank was cracked and spraying the interior of the fridge
Symptom was water running out of bottom of fridge. Found water pooled up under bottom drawer. Removed (3) drawers and found water was "spraying" from the reservoir tank at back of fridge. Unboxed the new "tank" and confirmed it was the right one by holding it up to the one still in the fridge. Pulled fridge from the wall; removed the rear bottom cover panel on the back using the nutdriver. Removed the solenoid assy by taking that single hex screw out. Push down on the blue circular flange where tube supply enters solenoid, and release the tubing from the solenoid. Remove front bottom cover with phillips screwdriver. Located 2nd tubing connector below freezer (under the unit) and used the same procedure to release that tube from the coupling. Removed screws from tank on inside of fridge, after removing several shelves that were in front of it. Pulled the tubing from the old unit up and out. Discard. Got new unit and fed tubes through the hole the others came out of (back right corner of fridge) MAKE SURE THE NEW TUBES HAVE THEIR "stoppers" IN PLACE. You don't want to contaminate the new tubes with insulation or other debris. Make sure the "o" ring that seals the tubes on the inside of the fridge (supplied with new unit)and the styrofoam insulation stays in place to keep air from leaking through the holes the tubes go through. Installation of the (2) tubes is simple, simply push them into the connector on the solenoid, and the coupler under the freezer. You'll need to feed the longer tube from the back to the front left corner where this coupler is. After making the connection, I bolted the solenoid unit back to the fridge (only 1 screw) and then tested the unit to see there were no leaks before I buttoned everything up. NO LEAKS!! Put the front bottom grill back on with the (2) phillips screws, and the back bottom cover back on with the hex screws removed near the beginning. Probably took longer to write this than it did to make the repair.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from Greenville, NC
- Parts Used:
- WR62X23154
- Difficulty Level:
- Difficult
- Total Repair Time:
- More than 2 hours
- Tools:
- Nutdriver, Screw drivers
Ice maker dispensed crushed ice but not cubes
Removed the ice bin and maker, then removed cover from the rear that covered the solenoid that controls the dispensing mechanism. Replace solenoid. The tricky part here is that there is a styrofoam cover around the solenoid pin that needs to be superglued into place and oriented properly during replacement. All electrical feeds snap out neatly and are easily replaced. Reassemble ice dispenser and bin, and viola, your back in business.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from West Palm Beach, FL
- Parts Used:
- WR51X10101
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
frost builds up in freezer section and refrigerator stops working slowly. manually defrost for 24-48 hours and starts working perfect. Goes through the cycle again after a week.
As advised by the forum just replaced the defrost heater assembly now the refrigerator works perfect. did not have to replace the thermostat.
My nephew had exactly same problem on ge refrigerator - replaced the defrost heater assembly and the problem is solved. Just remove the back panel in the freezer compartment, disconnect the cable, remove the nuts and replace the assemble. It is very simple. Bought both assembly from parts select.com - got next day delivery. they are great. would do business in future.
My nephew had exactly same problem on ge refrigerator - replaced the defrost heater assembly and the problem is solved. Just remove the back panel in the freezer compartment, disconnect the cable, remove the nuts and replace the assemble. It is very simple. Bought both assembly from parts select.com - got next day delivery. they are great. would do business in future.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Bradley from Spokane, WA
- Parts Used:
- WR49X10091
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Water line froze, food in fridge started freezing
I knew almost as soon as I found the frozen milk that the air-flow diverter, whatever it's called, had broken. It's a plastic part that opens and closes to allow cold air from the freezer into the fridge side.
Step one: clear off the top two shelves and take them out.
Step two: remove the lower piece of the assembly. It pops straight out at the top and drops down after that. If you pull the bottom straight out, you may break the bits that holds it to the fridge wall.
Step three: remove screws holding in light, and then the screws holding in the AASM COVER FF INLET K (wish I had a better name for it).
Step Four: Unplug the unit from the fridge wall.
Installation, reverse, except maybe unplug the unit earlier.
Step one: clear off the top two shelves and take them out.
Step two: remove the lower piece of the assembly. It pops straight out at the top and drops down after that. If you pull the bottom straight out, you may break the bits that holds it to the fridge wall.
Step three: remove screws holding in light, and then the screws holding in the AASM COVER FF INLET K (wish I had a better name for it).
Step Four: Unplug the unit from the fridge wall.
Installation, reverse, except maybe unplug the unit earlier.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- CLIFFORD from SPRING CITY, PA
- Parts Used:
- WR51X10101
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers, Socket set
Freezer Cold, Refrigerator Section Warm
The problem with this model is usually a burned out heater assembly, when the freezer is still freezing, but the fresh food section is warm. To check, first disconnect power from refrigerator. Remove food and then shelves from freezer section. Remove the screws that hold the back freezer panel in place. Remove back panel and the coils will be exposed. If they are covered in ice the heater is most likely the problem. At the bottom of the coils below the heater assembly is a drain hole plug this hole with a rag. Place a large towel in bottom of freezer pan beneath the coils to catch the water. I do not recommend any method to melt the ice from the coils but a hair dryer, do not chip at the ice or you will most likely damage the coils. After you have defrosted the coils and removed all water from the unit, remove the two screws that hold the heater element in place, this element is directly below the coils. Look at the element, if it is burnt black, this is a tell tale sign it is bad. If that is the case it will need to be replaced. Remove the electrical wires located on te end of unit, the new unit will have instructions with it, reconnect the electrical wires per instructions, remount heater with the same mounting screws that held it in place. Be sure to remove rag from drain hole, replace back freezer panel with screws, replace shelves, and plug refrigerator back in. If your problem was a cold freezer section but a warm fresh food section this should fix your problem. In conclusion, this problem and the fix for it is indicative to these model's ge refrigerator's
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from Tacoma, WA
- Parts Used:
- MWFP
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
water running slow
unscrewed old filter by hand, installed new filter.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- BABU from GRAND PRAIRIE, TX
- Parts Used:
- WR57X33326
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers, Wrench (Adjustable), Wrench set
Water is not coming from front door dispenser, but ice maker works well
On one severe winter cold night my fridge dispenser door stopped water supply, but ice maker was working. First I disconnected power supply to the fridge then turned off main water supply from the wall to fridge and with wrench set disconnected water supply pipe from wall to fridge while disconnecting the pipe make sure to collect the water from the both end pipes. Then removed the cardboard from the back side of the fridge. I disconnected the blue element (dispenser water) the red element (ice maker). [DOUBLE OUTLET WATER VALVE]. If you would try to pull the pipes white (dispenser water) and black (ice maker) you woudn't succeed because once the the white and black pipes are insereted into the water valve those pipes are clamped tightly in the valve. So I cut off those pipes and removed the old water valve, then I conncected the new water valve first conncected those white and blue elements and inserted the white and black pipes pushed in closed with round plactic caps comes with new one.I reconncected the main water supply pipes from wall to the frige and turned on the water supply from wall and plugged the power supply. First surpisingly I doubted it will work, actullay the water dispnser did'nt work immediately I have to wait 2 to 3 hours of time, in the mean time I checked the pipe connections from the bottom of the front left side door ( if you open the two doors bottom you can see the plastic cover it can be removed by pulling towards and pushing in you can close it back into normal position) which water supply pipe comes through the bottom of the door to water dispenser. I disconnected the connector and pusheed the dispensor several times to flushout any leaky water or air then I reconnected the pipes to the connector. I pushed the dispenser with a cup to dispenser, it started working as it is normally. While I was working my 7 years old son helped me as he always eager to learn and explore things.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Daniel from Anderson, SC
- Parts Used:
- WR57X33326
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
I had a water leak (undiscovered) from under my refrig
After de-energized unit (by removing electical plug from outlet),I removed the rear panel at bottom of unit. I then removed the mounting screw to the water valve. I then disconnected the wiring assembly from the old unit. I then removed the water supply lines going to the icemaker and water filter. I then placed the water supply into the replacement water valve. plugged in wiring assembly to new unit and rehung water valve inside refrig. Turned water valve on at water supply to check for leaks, finding none I then replaced back panel on refridge and plugged in electrical cord and returned refrige to normal place in kitchen.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from Dexter, MO
- Parts Used:
- WR57X33326
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Wrench (Adjustable)
Water leaked constantly from water dispenser in door
Had to turn off water and remove back panel and with a few tools the part was off and the new part put on in less that 30 minutes!! Finding parts on your website were easily found.
Was this instruction helpful to you?
Thank you for voting!