refrigerator and freezer would not cool down.
First, we called Sears Repair and had a technician come to our home. He stated the motherboard had gone bad probably due to a power surge (we had no surge protector on the appliance). His price for repair was $465.00. We opted to go online for the part and found it for $165.00 through PartSelect.com. It was a very simple procedure of removing the old and installing the new. A few turns with the nut driver to uncover the part, a few tugs with the pliers to disconnect and voila!.. The fridge was back to cooling in no time.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ricky from Virginia Beach, VA
- Parts Used:
- WR02X45206
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Screw drivers, Socket set, Wrench (Adjustable)
Low water flow from indoor water dispenser
Disconnect main water line from behind refrigerator
Remove bottom panel from refrigerator
Disconnect hose from water valve
Remove metal hose guard from top left of refrigerator Carefully remove plumbers putty from around filter hose (you will be reinstalling this putty around new hose assembly)
Inside refrigerator remove MWF water filter and guard, and then remove two screws holding filter assembly in place (this requires socket set with 4” extension bar)
Carefully pull filter hose assembly towards you from front of refrigerator. Once assembly is out remove Styrofoam cover from old assembly and install on new assembly
To reassemble, simply follow this process in reverse. Good luck
Remove bottom panel from refrigerator
Disconnect hose from water valve
Remove metal hose guard from top left of refrigerator Carefully remove plumbers putty from around filter hose (you will be reinstalling this putty around new hose assembly)
Inside refrigerator remove MWF water filter and guard, and then remove two screws holding filter assembly in place (this requires socket set with 4” extension bar)
Carefully pull filter hose assembly towards you from front of refrigerator. Once assembly is out remove Styrofoam cover from old assembly and install on new assembly
To reassemble, simply follow this process in reverse. Good luck
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Frederick K from Kingston, TN
- Parts Used:
- WR49X10091
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
GE Profile Arctica food locker was below freezing
The trouble shooting information on the web site indicated that the damper door within the climate control unit may be broken. This was easily confirmed and the replacement of the climate control unit immediately returned the food locker temperatures to the digital electronic thermostat settings. The part has an improved ventilation gasket interface between the food locker and freezer. The unit works perfectly again, and the food locker temperature is exactly what the thermostat setting is.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Michael from Ramona, CA
- Parts Used:
- WR50X10068, WR51X10101
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers, Socket set
Freezing up
Repair man said we needed a new circuite board, which I ordered and installed, however didn't fix the problem. Freezer was still freezing up, so I ordered a new defrost heater and thermostate. Installed yesterday, so it will be a week or so before I can check to see if this repair is working. However, replacement of these parts was very easy, and online ordering and delivery service the best. Keeping fingers crossed this repair does the trick. Best, Mike
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Robert from Huber Heights, OH
- Parts Used:
- WR57X33326
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers
water dispenser was slowly leaking
Shut off water supply. Unplugged refrigerator. Removed cover. (6 screws -- nutdriver will come in handy). Removed screw securing water valve to frame (again the nutdriver). Unplugged red and white power connectors to solenoids. Using channel locks, loosened nut holding main water supply to valve and removed. Depressed compression fittings to valve and pulled out plastic water lines that supply water dispenser and ice maker. Reconnected main water supply to new part. Pushed both water lines into respective fittings of new part. Reconnected power supply to solenoids. Attached new part to frame with screw. Replaced back cover. Turned water supply back on. Plugged refrig. back in. Problem solved! Savings = $300!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Timothy from Hartford, MI
- Parts Used:
- WR51X10101
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Screw drivers
Coils in Freezer over frosted restricting air flow.Warm Frig.
1) Unplug Refrigerator. Remove all shelves and light shield in the freezer.
2)Remove panel covering refrigeration coils inside freezer in back. Two hex head screws w/nut driver.
3)Remove the defrost heater using phillips screw driver. Two screws.
4)Unplug two quick disconnect stakons and wires from heater.
5)Plug the wire coming down the right side into one side of the new heater and plug the shipped white wire into the other quick disconnect spade at the heater.
6)Install the new dual element defrost heater into the same place where the old was. Connections to the right.
7)Route the wire that was on the left across the top of the coils and down the right side.
8)Bring the existing wire from the left side down the right side and the white wire up the right side. Wires should not be tight at all and do not remove the tape at the stakon.
9)Now wires need to be cut (if necessary)and crimped together in the shipped stakon. This stakon looks like a wire nut.
10)Wires should be tucked gently into the styrofoam up and down the right side. Wirenut should be positioned so that water can not collect in it.
11)Replace the panel over the cooling coils.
12)Plug Refigerator back into the wall outlet. Put shelves and light shield back in.
13)My refrigerator is now working without a problem. It's been est two weeks.
Ice maker is also working correctly.
2)Remove panel covering refrigeration coils inside freezer in back. Two hex head screws w/nut driver.
3)Remove the defrost heater using phillips screw driver. Two screws.
4)Unplug two quick disconnect stakons and wires from heater.
5)Plug the wire coming down the right side into one side of the new heater and plug the shipped white wire into the other quick disconnect spade at the heater.
6)Install the new dual element defrost heater into the same place where the old was. Connections to the right.
7)Route the wire that was on the left across the top of the coils and down the right side.
8)Bring the existing wire from the left side down the right side and the white wire up the right side. Wires should not be tight at all and do not remove the tape at the stakon.
9)Now wires need to be cut (if necessary)and crimped together in the shipped stakon. This stakon looks like a wire nut.
10)Wires should be tucked gently into the styrofoam up and down the right side. Wirenut should be positioned so that water can not collect in it.
11)Replace the panel over the cooling coils.
12)Plug Refigerator back into the wall outlet. Put shelves and light shield back in.
13)My refrigerator is now working without a problem. It's been est two weeks.
Ice maker is also working correctly.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Gerald from Colorado Springs, CO
- Parts Used:
- WR57X33326
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Socket set, Wrench set
water leak on floor
pulled out refer. found leak at corner lower back, pulled off lower cover. found valve for icemaker leaking. looked in owners/inst guide, pulled up on computer, identified part, called, order overnight part. recieved part & installed, repair complete & successful.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mark from Ramona, CA
- Parts Used:
- WR17X11655
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 1- 2 hours
The grill flew off going down the freeway.
I took the part out of the package and placed it in the recessed water dispenser/ice maker cavity. Done!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from WATERLOO, NY
- Parts Used:
- WR57X33326
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Socket set, Wrench set
Ice maker working but water dispenser not working
The very first symptom here is important! The door water dispenser is not working but the ice macine is working. You may only have a frozen water tube in the door so do the following before diagnosing that your solenoid valve is bad: 1) the tube usually runs under the front of the refrigerator and usually has a quick disconnect. Undo the connection and press the dispenser. If water comes out of the tube you have a frozen or blocked tube in the door. 2) Immediately adjust the temperature in the freezer and warm the freezer compartment as much as you can without destroying the freezer contents. Wait 24 hours. This will usually unfreeze the line. Do not waste your time with a hair dryer. NOW, if this doesn't work and you are convinced you need to order and replace the solenoid, follow these steps. Assemble your tools first. I needed a good ratchet set and a screwdriver. A shop towel is helpful for spilled water. A light is handy. Pull out the refrigerator to gain access to the rear of the unit. Unplug the power and close the water valve (older homes, you may need to actually shut the house water supply). Remove the screws which hold the cover over the lower half of the refrigerator. On the left you will see the solenoid. It's always good to see that your new part matches the one you feel needs replaced. They may not match perfectly due to changing design but they should be very similar. One screw holds this part in place and access is very simple. Now simply unplug the electrical connections. In my case, one blue "blade" type connection (powering the water) and one red "blade" type connection powering the ice maker. They are not the same size and this coupled with the coloring means you will not accidently switch them. pull the tubes clear of the solenoid. This is simple and needs no explanation. Grab your new solenoid and reattach both the electrical and water lines (two, remember, ice maker and drink dispencer). Replace the single screw. Re-attach the rear, lower refrigerator cover and go to the front of the unit to check the water. You can listen carefully and hear the power engage from the new part bringing you water. Clean up, replace the refrigerator back to its place and look really tired when your wife sees that you worked "so hard"! You probably saved at least $50-$80 from a service call.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jonathan from NEW ORLEANS, LA
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Very Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Socket set
Refrigerator and freezer would stop cooling. Would happen suddenly without warning. Reset of refrigerator would solve the problem and it would run fine for several days before doing it again.
Only tool I used was 1/4 inch socket. Using the 1/4 inch socket, the screws were removed from the panel covering the control board. (this is on the back in the lower right corner). When this panel is off you are looking at the control board. Next remove all the plug in connectors. Don't worry about remembering where they go. They all are different and can only go in their specific place. After removing the connectors, pull the board out. Replace the plug in connectors before putting the new board back in , then snap the board back into place.(held in by four pins). Replace the cover.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Amy from Bryan, TX
- Parts Used:
- MWFP, WR02X11330
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers
union connector leaking
replaced with new connector and it worked great. also replaced the water filter and that was super easy!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jeff from Manteca, CA
- Parts Used:
- WR49X10091
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Water will not dispense and the refrigerator drawers were freezing our foods and vegetables.
It was a simple remove and replace. The new part fits directly in place of the old part. Its a pain to remove the light but once you get the light out the job is simple. The light must be pried out gently. It is snapped in place toward the air inlet cover and needs to be pried loose. Once the light is out there are 4 screws holding the air inlet cover in place. Remove the 4 screws and unfasten the wiring harness. Once the screws and wiring harness are disconnected remove the old part. Reinstall the new part in reverse order.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jake from Brainerd, MN
- Parts Used:
- WR57X33326
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Screw drivers, Wrench (Adjustable)
Ice maker inlet tube was freezing up, and eventually the icemaker overfilled and completely froze up
After lots of research online, i narrowed my problem down to be the double outlet water valve, behind the fridge. My biggest problem was getting the refridgerator out of its spot, but after that it was pretty simple to change. I took the cover off the bottom, in the back of the fridge, then i removed the inlet waterline (after i turned off the water supply to the fridge). After that i removed the screw that holds the valve to the framework. Now i pulled off the two other waterlines from the old valve and moved them, one at a time, over to the new valve, along with the wire harness. The rest of the instalation was reverse order. Simple fix that im glad i didn't pay an expert to do!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ron from ORANGE, CA
- Parts Used:
- WR30X10093
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
Unit had stopped making ice
Ordered the icemaker replacement. unplugged the unit, followed the simple instructions and got it done in less than 30 minutes. It did take a LONG time to start making ice. But it's working now.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Michelle from Minneapolis, MN
- Parts Used:
- WR51X10101, WR50X10068
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Freezer section was too warm
Both parts were easy to install and they fixed the problem. It is a two person project as it is very hard to get both hands inside the freezer section because it is so narrow. Be sure to orient the wire nuts in the right direction to avoid condensation and follow the instructions to create a drip loop on the wire connectors. We reviewed many "fix it" forums and almost bought the mother board. Really glad we found parts select, saved over $100.