Customer:
Jeffrey from Bluefield, WV
Parts Used:
WR30X10093
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
Ice maker quit making ice
the first thing i did was replace the water valve at the bottom of the refrigerator but that didn't work so then i spent more time researching the problem on your site and your diagnostic said to replace the ice maker so i ordered it, took the old one out, plugged the new one in and we had ice the next day.
40 of 50 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert from Battle Creek, MI
Parts Used:
WR55X10942
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
Unit would not run.
I found if I would put pressure on one connector on the board the unit would come on. So the board had a short. I ordered it, it came in 24 hours and I installed it and problem was solved.
34 of 36 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
James from Greenville, NC
Parts Used:
WR62X23154
Difficulty Level:
Difficult
Total Repair Time:
More than 2 hours
Tools:
Nutdriver, Screw drivers
Ice maker dispensed crushed ice but not cubes
Removed the ice bin and maker, then removed cover from the rear that covered the solenoid that controls the dispensing mechanism. Replace solenoid. The tricky part here is that there is a styrofoam cover around the solenoid pin that needs to be superglued into place and oriented properly during replacement. All electrical feeds snap out neatly and are easily replaced. Reassemble ice dispenser and bin, and viola, your back in business.
42 of 60 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Joe from Brentwood, TN
Parts Used:
WR30X10093
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Quit making ice.
There were not two screws as the instructions said. There was only one screw and I had to firmly pull it out after taking out the one screw. Then, to put the new one in, I had to line up two slots on two knob-like things and push it in firmly. Then screw the one screw in.

Other than the two-screw problem, it was easy.
37 of 47 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
FERNANDO from MIAMI, FL
Parts Used:
WR51X10055
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Pliers, Screw drivers
Refrigerator Not Cooling due to ice buildup on coils
Removed shelves from freezer section and removed protective cover using a screwdriver and nutdriver. 5 screws.
Upon removal of the cover, I noticed the coils totally cover with ice. At this point I noticed that the defrost heater was burnt out. I removed the heater using screwdriver and pliers and tested the heater according to instructions from Parts Select website.
Since the coil was exposed, I also tested the defrost thermostat according to Parts select instructions and found it to be working properly. i also tested the defrost timer and found it OK.
I replaced the heater, closed the protective cover, replaced the shelves and plugged the unit on.
It has been working just fine since then..
In addition to saving money, i saved myself the agravation of looking for a repairman and having to wait for THEIR convenience to to the work.
35 of 41 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Steven from Cave Creek, AZ
Parts Used:
WR30X10093
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Pliers, Screw drivers, Socket set, Wrench set
ice maker leaked water slowly and froze the cubes together
The replacement ice maker that GE supplies for my old refrigerator is a little different than the original. The electrical plug changed from a round plug to a square one. They include an adapter for it, but DON'T USE IT. There's not enough room for the bulky cord and connector. I got a much cleaner installation by taking apart the old and the new ice maker, and then splicing in the old connector into the new ice maker. You need to carefully unscrew a circuit board inside to wire it in, and it'll be more secure if you solider 3 wires instead of using crimp connectors. The instructions also tell you to use your old 'ice breaker', but it won't fit on the new ice maker. I just left the new ice maker's ice breaker on, and it seems to work perfect.
41 of 60 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Michael from Milton, FL
Parts Used:
WR55X10025
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers
Freezer would not defrost correctly
Took panel off back of inside of freezer section, took off old sensor from the evaporator, spliced new sensor into the existing wires, waterproofed spliced connections, snapped sensor back onto evaporator, then put panel back on the inside of the freezer. Really, it took only 10 minutes to fix. Now refrigerator defrosts like it used to, and temps have settled in at specified temps.
32 of 34 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Bradley from Spokane, WA
Parts Used:
WR49X10091
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Water line froze, food in fridge started freezing
I knew almost as soon as I found the frozen milk that the air-flow diverter, whatever it's called, had broken. It's a plastic part that opens and closes to allow cold air from the freezer into the fridge side.

Step one: clear off the top two shelves and take them out.

Step two: remove the lower piece of the assembly. It pops straight out at the top and drops down after that. If you pull the bottom straight out, you may break the bits that holds it to the fridge wall.

Step three: remove screws holding in light, and then the screws holding in the AASM COVER FF INLET K (wish I had a better name for it).

Step Four: Unplug the unit from the fridge wall.

Installation, reverse, except maybe unplug the unit earlier.
33 of 37 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jeffrey from Highlands Ranch, CO
Parts Used:
WR55X10942
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers
Icemaker would not dispense cubes or crushed ice
Cause: Failed relays on main circuit board. Fix: Main circuit board replacement: Unplugged refrigerator. Removed 10 screws securing main circuit board metal cover (located on back of refrigerator) using a nutdriver. Disconnected 7 multi-pin electrical connectors from the circuit-board by firmly pulling each connector from the circuitboard sockets using a needlenose plyers. Depressed the small locking prong on each of the 4 plastic circuit board mounting pegs while pulling the board off the mounting pegs.
Pressed new board in place over mounting pegs. Re-plugged in all connectors (no confusion because each connector has unique pin counts). Replaced all mounting cover bolts, making sure to pin green ground wire to last bolt. Plugged in refrigerator. Done.
Note: I determined the main circuit board was bad by removing the auger motor assembly from the freezer and testing the auger motor harness power pins. AC voltage should jump when ice demand lever is pushed (while pressing the internal door light off switch). If no voltage jump, then auger motor relays on main circuit board have failed, indicating board replacement is needed.
Another check would be connecting an extension cord to the auger motor terminals and plugging it in. Motor should run. If it does, then motor is good and main circuit board is bad. If it doesn’t then auger motor is bad and needs replacement.
33 of 38 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from Lodi, CA
Parts Used:
WR30X10093
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Ice was melting and freezing in bucket
Frig and freezer were defrosting and refreezing other than normal. Home warranty contractor told me ice maker was faulty. Purchased new ice maker. Unplugged frig, loosened 2 screws with nut driver. unplugged old ice maker, lifted old ice maker out. Took old fill cup off old unit and put on new unit since new fill cup was a different size. Swapped ice maker insert from old to new unit. Plugged in new ice maker, slid over the 2 screws, tightened, and plugged in frig power. New ice maker works fine but still have defrosting and refreezing problem. Figure old ice maker probably works just fine. New contractor still trying to solve problem. Have had problems with this GE Monagram keeping proper temps since it was new in 2005, don't recommend it.
33 of 41 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
john from waxahachie, TX
Parts Used:
WR55X10942
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Pliers
No water or ice and a constant ticking sound from the control panel
Very easy repair to do. Read instruction sheet before starting! Unplug unit prior to removing panel cover.

Remove three hex head screws holding control panel cover in place and reveal the circuit board.

Remove all the wiring harnesses by gently pulling them from the sockets on the board. Do not pull the wires - make sure you pull on the plastic socket so that the wires aren't damaged. If plugs seem tight use needle nose pliers to gently wiggle them out. Remove earth (green) wire from spade connection on fridge chassis. The new board has a slightly different connection for the earth wire.(No spade connector - wire now has a ring connector that attaches between panel cover and fridge chassis using one of the hex head panel screws when the cover is replaced.

Using needle nose pliers locate four plastic mounting tabs holding the board in place and squeeze in the end of each tab whilst gently pulling the board off it. Repeat for all four tabs and remove old circuit board.

Making sure the new board is the right way round locate it on the plastic tabs and push gently until you hear the tabs click. Gently pull the circuit board to ensure it is locked in place.

Re-install all the wiring harnesses. Put a hex head screw through the cover panel and slip the earth wire ring over it and screw panel to chassis. Replace two remaining hex head screws and plug fridge back in.

Voila!! No more ticking sounds and a plentiful supply of ice and water!!
32 of 39 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Joe from Suffolk, VA
Parts Used:
WR55X10025
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers
Ice & Ice Cream would melt and refreeze
Noticed the problem in November 2009. Replaced Hi Limit Sesor for Defrost thinking it was the freezor temperature sensor. Did not fix the problem. Replaced Motherboard. Did not fix the problem. Called Sears Repair. They mis-diagnosed the problem and told me it was the sealed system. I doubted them and sent them home. Replaced the correct freezer temperature sensor that connects to the motherboard. FIXED.
Removed a panel, cut two wires, soldered and insulated two wries, reinstalled panel.
30 of 34 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Morgan from Acworth, GA
Parts Used:
WR71X10761
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
The clear plastic module shelf insert broke because I dropped it.
I popped out the old one and popped in the new one.
30 of 36 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Michael from Otsego, MN
Parts Used:
WR62X10055, WR55X10942
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers, Screw drivers
water & Ice disspenser quite working
first replace the solenoid behind the front display. than replace the mother board on the back side of the fridge due to a relay being burned out on it.

GE Wanted $300 + to come out and do the repair.

With partsselect and a little time I cut that cost in half.

Thank you,

Mike
29 of 37 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mark from Skokie, IL
Parts Used:
WR62X10055, WR17X11655
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Icemaker switch on door would not trigger motor
Replacing servo was not hard, but did not solve problem. Searched some more and the cure is to remove the light bulb from the dispenser. Seems that old bulbs draw too much current and cause the control panel to fail in sending signal to icemaker motor. Removing the bulb cured this fault and the control panel worked fine.
28 of 35 people found this instruction helpful.
Was this instruction helpful to you?