Ice Maker wouldn't work, water tube freezing up, water leaking onto floor
My problem was that the tube from the water valve to the ice maker was freezing when the valve was malfuntioning and sending more water, causing it to back up and freeze in the reception tube. Then the plastic water tube from the valve to the freezer seperated and water was leaking onto the floor. By reading the repair storyies on the Partselect website I learned that the water valve was not working correctly and needed replacing. I ordered the replacement part on a Wednesday evening and had the part at my house via FEDEX on Saturday morning. It took me about 20 minuttes to complete the entire repair.
I had shut the water off to the valve and unplugged the refrigerator.
First I took the ice storage unit out of the freezer. I then unsrewed the ice making tray from the left side of the freezer. I lowered the unit to the shelve but did not disconnect the wiring. I then pulled the water reception tube that goes from the ice maker to the outside of the refrigerator on the top right rear. There was grozen water contained in the tube. I ran it under the sink and released the frozen water so the tube was clear. I reinserted into the tunnel it sits in and reattached it to the 90 degree plaqstic fitting in the outside of the right rear of the refrigerator.I reattached the plastic water hose from the water valve to the 90 degree fitting. I then reattached the ice maker in the freezer compartment.
Using a nut driver I removered the rear cardboard cover and insulation from the right rear side of the refrigerator. Using a box wrench I unscrewed and disconnected the copper water tube from the valve. I then removed the srew holding the water supply copper tubing to the refrigerator and removed the srew holding the water valve in place.
I removed the old valve from the back of the refrigerator.
I then took note of the electrical connections and transferred them to the new valve. I needed the two adapters(supplied) for the right side electric terminal.
I then transferred the water connection tubes. Take note one is larger than the other. On the old valve they screwed into the water valve with a compression nut. On the new valve you only needed to insert the plastic water tube into the right size hole and push. The comression connection is automatic and does not require the nut. ( I just pushed the nuts back on the tubing and left them). There is a plastic seperation piece on the new valve. I just twisted it loose and removed it. This allowed ease in positioning the valve and water tubes.
I then inserted the new valve into the right rear of the refrigerator and resrewed the unit to the frame using the nut driver.
I then re-attached the water supply copper tubing onto the nipple on the new valve and using a box wrench re-attached same.
I then turned on the water supply to the refrigerator and checked for leaks.
I then replugged the refrigerator into the electical outlet and started the ice maker cycle.
I waited to see that all was working correctly. i then re-attached the insulation and cardboard cover on the rear of the refrigerator and pushed the unit back into the wall space.
Everything is working great now!
I had shut the water off to the valve and unplugged the refrigerator.
First I took the ice storage unit out of the freezer. I then unsrewed the ice making tray from the left side of the freezer. I lowered the unit to the shelve but did not disconnect the wiring. I then pulled the water reception tube that goes from the ice maker to the outside of the refrigerator on the top right rear. There was grozen water contained in the tube. I ran it under the sink and released the frozen water so the tube was clear. I reinserted into the tunnel it sits in and reattached it to the 90 degree plaqstic fitting in the outside of the right rear of the refrigerator.I reattached the plastic water hose from the water valve to the 90 degree fitting. I then reattached the ice maker in the freezer compartment.
Using a nut driver I removered the rear cardboard cover and insulation from the right rear side of the refrigerator. Using a box wrench I unscrewed and disconnected the copper water tube from the valve. I then removed the srew holding the water supply copper tubing to the refrigerator and removed the srew holding the water valve in place.
I removed the old valve from the back of the refrigerator.
I then took note of the electrical connections and transferred them to the new valve. I needed the two adapters(supplied) for the right side electric terminal.
I then transferred the water connection tubes. Take note one is larger than the other. On the old valve they screwed into the water valve with a compression nut. On the new valve you only needed to insert the plastic water tube into the right size hole and push. The comression connection is automatic and does not require the nut. ( I just pushed the nuts back on the tubing and left them). There is a plastic seperation piece on the new valve. I just twisted it loose and removed it. This allowed ease in positioning the valve and water tubes.
I then inserted the new valve into the right rear of the refrigerator and resrewed the unit to the frame using the nut driver.
I then re-attached the water supply copper tubing onto the nipple on the new valve and using a box wrench re-attached same.
I then turned on the water supply to the refrigerator and checked for leaks.
I then replugged the refrigerator into the electical outlet and started the ice maker cycle.
I waited to see that all was working correctly. i then re-attached the insulation and cardboard cover on the rear of the refrigerator and pushed the unit back into the wall space.
Everything is working great now!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Eric from Rose Hill, KS
- Parts Used:
- WR57X10051
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Solenoid controlling the valve had stopped operating.
I first tested to make sure the solenoid was receiving power. Every time the arm on the ice maker cycled, the meter would go up to 120v for about 10-15 seconds, and then back to almost 0, so I knew the electical control and timer was working as it should.
The valve was easy to change - took about 20 minutes total (including pulling the fridge out and pushing it back in). I just turned the water off, removed the valve assembly from the fridge, and took all of the lines off of the old one. I then hooked up the supply line to the new valve assembly. The lines to the water and ice had compression fittings on them, but the new vavle has a "push-in" connector. So, I cut the old water and ice lines squarely, just past the fitting, then pushed them in firmly. Plugged the connectors in, re-attached the vavle assembly to the fridge, turned the water back on, and viola - I had ice in about an hour! Gravy! :)
The valve was easy to change - took about 20 minutes total (including pulling the fridge out and pushing it back in). I just turned the water off, removed the valve assembly from the fridge, and took all of the lines off of the old one. I then hooked up the supply line to the new valve assembly. The lines to the water and ice had compression fittings on them, but the new vavle has a "push-in" connector. So, I cut the old water and ice lines squarely, just past the fitting, then pushed them in firmly. Plugged the connectors in, re-attached the vavle assembly to the fridge, turned the water back on, and viola - I had ice in about an hour! Gravy! :)
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- donald from opelousas, LA
- Parts Used:
- WR60X187
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
noise from condenser fan
disconnect the power to the unit. remove the retainer sctrews on the mounting bracket. remove fan motor from unit. using the rerquired tools remove the fan from the old motor and install on the new one. torque the nut until all slack is out then 1/4 turn. reinstall motor assy. and reconnect power. test the system .
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- George from Brandywine, MD
- Parts Used:
- WR57X10051
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
no Ice
Turned off The water supply. Removed the back panel corner(nut driver). Removed valve (nut driver) and water supply inlet line. Cut the old outlet lines at the valve (new lines are push in) disconnected electrical lines, Reinstalled inlet line and electrical lines. Reinstalled valve and back panel. Turned on the water. Ice maker filled with water and a short time later I had ice. Easy job.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Kathrine from FORT MILL, SC
- Parts Used:
- WR60X187
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Screw drivers, Socket set
There was a warm spot at the front edge of dividing wall. The fan motor was not working.
I followed the directions of Steve on the installation video. He makes it easy to do the repair with his step by step description of the installation. I have repaired three different aging appliances with help of Steve and PartSelect's very helpful Customer Service.
I wish Steve a wonderful retirement and hope PartSelect can find someone as easy to follow for future videos. The videos are priceless for the repairs.
I wish Steve a wonderful retirement and hope PartSelect can find someone as easy to follow for future videos. The videos are priceless for the repairs.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Peter from Ashford, CT
- Parts Used:
- WR57X10051
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers
Cold water dispencing was becoming slower and volume of ice was becoming less.
Shut water supply off, removed power plug from wall and removed electrical connector from valve. Unscrewed two plastic nuts which retained lines to old valve. Remove old valve and reinstalled new valve with one screw. Removed inserts from end of lines. (These inserts keep lines from deforming.). Trimmed and chamfered ends of lines reinstalled inserts and installed lines to new valve. Turned on watter, checked for leaks turned power on inserted glass for water received good flow. Ice maker did not receive water. Due to low flow of water to ice tray because of low flow with old valve, ice built up in flexable water delivery tube that goes from back of refrigator to ice tray. Removed tube ran under warm water removed ice blockage reinstall tube all working excelent. This iceing problem took about anouther 15 to 25 min to correct.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- ELLIOT from COS COB, CT
- Parts Used:
- WR60X10009
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Socket set
Freezer Evporator Fan Motor Failed
Unplugged power supply, dis-assembled fan motor housing, opened back panel partially to remove entire fan unit, took off fan, put onto new motor, re-assembled in reverse order and plugged in power supply. Wha la!! Everything running smoothly, original settings '3' for freezer '5' for refrig and evp fan motor running about 1 hour then shut off all night until next morning came back on as usual. Thanks parts select for making a headache go away so quickly. Ordered part online, received tracking details, received part in 3 biz days, and installed in 30mins. Refrigerator good as new, infact, better because I cleaned up freezer of food spills, and wiped clean all trays. Brgds elliot rund satisfied consumer, repeat customer for future.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jerry from Hurst, TX
- Parts Used:
- WR57X10051
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Pliers
My wife called me at work and said the refrigerator was "peeing" on the floor.
When I got home I pulled the refrigerator away from the floor, checked all the water lines for leak evidence, and then took the back panel off to check everything behind. The water valve was leaking at the hose insert locations. I turned off the water, spent less than 5 minutes disassembling the valve from the rerfrigerator, and got online to buy another one. The part arrived several days before expected, and it took me less time to install the new part than it did to take the old one out. Now all I have to do is repair the floor damage I caused when pulling out the refirgerator!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Frank from Florham Park, NJ
- Parts Used:
- WR57X10051
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Wrench set
Water was not running out of dispenser but the ice cube maker was working
Well I Googled the problem to the dual inlet water valve. Luckily I found PartSelect for the correct part and the installation was simple. I now have both the cubes and water working properly from the dispense.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Terry from Grand Forks, ND
- Parts Used:
- WR57X10051
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Water valve cracked
Pulled out the fridge - unpluged. Water supply was already closed.
Then took off the cardboard cover in the back. Used a nut driver to remove 1 screw. Disconnected water lines and elec. connects.
Water lines slid into quick connects - connected electrical and mounted. Opened water suply needle valve.
Pluged in fridge did a quick test for leaks. Done in 5min.
Then took off the cardboard cover in the back. Used a nut driver to remove 1 screw. Disconnected water lines and elec. connects.
Water lines slid into quick connects - connected electrical and mounted. Opened water suply needle valve.
Pluged in fridge did a quick test for leaks. Done in 5min.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mary from Fort Collins, CO
- Parts Used:
- WR32X1461
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
drawer was broken
The replacement part fit perfectly and was easy to install. No problems at all.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Tony from Charlotte, NC
- Parts Used:
- WR57X10051
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Water won't stop running in Ice Maker
Basically I looked online for some research thru google and found this great site.. A few other folks had the same problem as I had with mine and I figured that I would start with replacing the double outlet water valve.. So I ordered it from this site and in two days wow that's fast shipping.. This repair took less than 15 minutes to complete and talk about a big savings $ 45.00 for this repair job.... I'm really happy now.... It's pretty easy though.. simply unplug frig first... then remove screw holding the valve.. remove clips and have a bowl near by when remoing the two hoses... replace valve.. its all colored coded just match the colors and then the two hoses they are different sizes one for each hole... reclip the clips and then replace the screw and finally plug the frig back in.. and then turn on the water to check for leaks.. if no leaks you are done...
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- andy from clearwater, FL
- Parts Used:
- WR57X10051
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
Ice maker leaks water freezing ice cubes into one block
Googled the problem, find parts select.com, called service rep and the female rep recommended this part.
Ordered part, got it, replaced it and it works fine.
Note: the water hoses are just installed by pushing in, no tools required.
Ordered part, got it, replaced it and it works fine.
Note: the water hoses are just installed by pushing in, no tools required.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from CLIFTON, NJ
- Parts Used:
- WR60X187
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
Fan would not turn when the refrigerator came on all the time. Would physically have to turn the fan blades.
Did not do the repair because the unit arrived damaged. The packaging was in good condition. The plastic around the plug in shattered, and some of the plastic was inside the motor. Very good, and fast on adjusting the order.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Gerald from WINTERVILLE, GA
- Parts Used:
- 40A15
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
lights blown out
replaced lights in refrigirator and freezer
Was this instruction helpful to you?