TPS24PIBABS General Electric Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Mark from Dumfries, VA
- Parts Used:
- WR57X10051
- Difficulty Level:
- Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Screw drivers, Wrench (Adjustable)
Water Valve Leaking
Removed lower cover screws removed cover removed copper water feed tubing connector unplugged wire connectors pulled out plastic water line connector and water lines removed water valve assembly installed water lines installed wire connectors secured valve assembly reinstalled copper water line turned on water valve checked for leaks reinstalled lower rear cover
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Louis from LEAGUE CITY, TX
- Parts Used:
- 40A15
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
Change bulb
Easy
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Karen from Gainesville, FL
- Parts Used:
- WR57X10051
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Wrench (Adjustable)
ice maker stopped working
I unplugged the refrigerator and shut off the water. I removed the back of the frig where the inlet valve is located. I removed the old nuts and cut the plastic water line on the ends. I shoved them into the new fittings. I then turned on the water and plugged in the frig. I could hear the water pumping into the ice maker. I screwed the inlet and back of refrigerator in place.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Johnathan from Gilbert, AZ
- Parts Used:
- WR57X10051
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Wrench (Adjustable)
Ice maker overflowing. Valve stuck open
The valve I got was slightly bent up. I spent the first 10 minutes or so bending it back with my muscles. once that was done, I took off the backing of the fridge with the screwdriver, undid the single bolt holding the valve on, and unplugged it all (fridge was already unplugged). Just like everyone says, the tubing connecter is different, so I took off the old compression fittings, and pushed the tubes in. THen I hooked up the wiring... I realized that that the wiring adapter was needed but there wasn't enough room for it as is.. so I have to bend the tabs so the wiring would angle down. Everything has worked perfect since... I got Ice and no leaks! woo hoo!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- kathleen from red oak, TX
- Parts Used:
- WR57X10051
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers, Wrench set
leaking water valve
I used a screwdriver to remove, then replace, the screw that holds in the valve. I used pliers to pull the refer water line out of the old valve. I just used my hands to reinstall the line. I used and open box wrench to remove and reattach the main water line. Nothing blocked access to the valve and it was very easy to remove the old one and install the new one.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Bobby A from Del City, OK
- Parts Used:
- WR57X10051
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
No water going into ice maker
Pulled the fridge out from the wall, disconnected the power cord,turned off the water supply,removed the backing that covers the fan/motor and the two way water valve. Removed one screw that holds water valve to back of fridge,removed two water lines. Installed the new water valve , connected water lines and screw, installed back dust cover, plugged in the 110 cord, turned on the water valve. Within 30 minutes a new tray of ice cubes was ejected into the ice holding box. Mission completed.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Tom from Forest, VA
- Parts Used:
- WR57X10051
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
leak from duel inlet water valve
Pulled unit away from wall. Removed lower panel. Turned off water and electricity. Removed two nuts holding valve. Disconnected electrial wiring. Cut water lines going into old valve close to the valve so the lines could be reused with new unit. Installed new valve by pressing lines into valve, reconnected electricity. Put two screws back in. Turned on water and electricity. Works great. No leaks. Results of leaks required hardwood floor to be repaired (sanded and refinished). Stayed away from kitchen for nine (9) days. Need to check for leaks everytime you clean under the refrigerator.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Lynn from White Pine, TN
- Parts Used:
- WR57X10051
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Socket set, Wrench (Adjustable)
leaking water inlet valve
Changing the valve was easy, remove and replace. The problem came afterwards. After shuting off the water and waiting for the replacement valve, the water line coming in to the icemaker froze solid causing water to spray into the freezer, causing a major leak. After thawing out the line, it still leaked because the water in the freezer had frozen up the freezer drain again causing another leak.Bottom line, after replaceing the valve, take a few extra minutes to check or replace the water line coming to the icemaker. That will save a headache later.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- percy from rosenberg, TX
- Parts Used:
- WR57X10051
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers, Wrench (Adjustable)
water kept freezing in tube to icemaker
removed backing from the refrigerator then unscrewed the pump from refrigerator unhooked the electrial connections. Then hooked up new pump by connectioning the elctrical then putting water connections back on with the quick connects then plugged refrigetator back in the reinstalled back of refrigerator and slide back into place as simple as 123
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Donald from Sugar Hill, GA
- Parts Used:
- WR57X10051
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers
Water was not filling icemaker.
It was very easy replacement. I was sent a different style that allowed for the water tubes to be pushed in compression wise instead of havinf to screw them on. The water was going ok to the cold water in the door but was not functioning for the ice maker. I had already replaced the ice maker unit due to a couple of missing teeth in the turn wheel but still could not get the water to fill. The original problem was created by the missing teeth creating a steady flow of water ultimately all over the floor. It took booth units to fix the problem and now the ice maker works as it should. The valve came with the proper connectors and the toughest part of the job was pulling out the frig. Nice to have something work as described and fit perfectly. A simple nut driver or socket was all that was needed for the entire job.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mark from Gilbert, AZ
- Parts Used:
- WR57X10051
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
We had water leaking all over the floor realized it was coming from our refrigerator.
We pulled out our refrigerator and found the leak coming from a valve that controlled the purified water and ice machine. We shut of the water source at our filter system and then removed the part. Looked online and found the part we needed at a great price. Ordered it and installed it when it arrived 3 days later. Easy install and we now have water and ice coming from our refrigerator again- not to mention a clean floor underneath too.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Kevin from Tuscola, IL
- Parts Used:
- WR57X10051
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Wrench set
Water leaked from body of Valve
Turned off water, ordered part based on photo and partial appliance model number (my model number was not listed); removed old part using hand wrench and nutdriver: slid existing retaining nuts up waterlines(left on for furture reuse if needed) and slid lines into "Pex" type connectors and remounted (one screw) valve to refrigerator and turned on water.
Note: From Part ordered to received was less than 36 hours!
Note: From Part ordered to received was less than 36 hours!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Malik from Lathrup Village, MI
- Parts Used:
- WR57X10051
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Ice build up in the freezer
It is a dream with less than a minute I unscrew the old part and install the new part
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Boyd from Rapid City, SD
- Parts Used:
- WR02X10098
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
The evaporator fan in the freezer compartment began making a loud noise.
I found a replacement evaporator fan motor and 2 mounting bracket grommets at PartSelect.com at a reasonable price. I watched the installation video provided and installed the new parts as shown in the video start to finish installation time 22 minutes.i
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Linda from Pittsfield, MA
- Parts Used:
- WR57X10051
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Wrench (Adjustable)
the original part had gotten a tiny pinhole in the plastic at the seam, probably due to age
After turning the water off and unplugging the refridgerator, I took the copper inlet tubing off using an adjustable wrench. I disconnected the two fuses that give power to the unit, and using a screwdriver, disconnected the water inlet/ outlet tubing from the old unit. I pushed the tubing into its proper place in the new unit, plugged in the two color coded fuses, used a wrench to reconnect the copper water tubing, and replaced the unit. EASY!!! So, easy, in fact that a non-handy girl could do it (and I can say that, being a non-handy girl!)
Was this instruction helpful to you?
Thank you for voting!