Customer:
Richard from Quakertown, PA
Parts Used:
WR51X443
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Socket set
would not defrost
First I removed the light cover, one screw. Then I removed the rear coil cover, three Phillips screws and two hex head screws. I then defrosted the coils and removed the old defrost element and wiring harness, two hex head screws held in the element, wiring harness just unplugs. I the installed the new defrost coils ( new one had two coils but had a previously designed area for the second element ) and ran the wiring harness up to where the plug was. I then reinstalled the coil cover plate, and light guard and started the refridgerator. Frige runs like new. Thank you PartSelect for the extremely propmt delivery and the correct part. part
7 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Todd from Saint Paul, MN
Parts Used:
WR60X30349
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers, Screw drivers
Noisy freezer evaporator fan, bearings worn out
UNPLUG UNIT. Open freezer compartment, top door. You may want to let it warm up a bit before beginning work. Next remove single screw from small square plastic grate at top left back of freezer compartment with phillips screw driver. Remove green ground wire connection behind removed grate with nut driver. Next remove 2 screws at top of freezer compartment holding plastic air diffuser bracket in place and holding back panel. Remove metal back panel of freezer by pulling top towards you, then angle out of compartment. Evap. fan is now exposed. I inspected and removed fan by removing two screws with nutdriver on bracket behind fan blade. I inserted nutdriver (with long socket driver)between fan blades to screws on bracket behind blade - 1 each side. After these two screws are removed, pull fan and bracket assembly out from plenum. Remove wiring from motor and remove motor to workbench. Remove round metal clamp from fan hub with needle nose pliers and slide off fan blade from motor. Also remove bracket and rubber bushing. Disgard old motor. Inspect and clean blade. Replace if necessary. Reattach rubber bushing, bracket THEN fan blade to new motor. New fan has atleast one terminal in new location and I had to use one wire extension that came with kit. Route wire behind motor and plug in new wires to back of motor. Insert fan and bracket to plenum, hold in place with one hand while reattaching screws with nutdriver between fan blades. Once fan is in place and nuts secure, I tested operation by plugging unit back in to make sure new motor ran and fan spun freely. Reattach back panel, top diffuser bracket and small grate with 3 screws. Shut door, set temp. and wait 24 hours before loading freezer. Unit good as new!
8 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Paul from Palmdale, CA
Parts Used:
WR51X443
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
freezer coil iceing up
removed freezer racks and back panel. removed and relaced defrosting harness. reassembled compartment
PartSelect rocks! easy to locate needed parts. price is fair and quick shipping. saved me $$$$
7 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Bill from Columbiana, AL
Parts Used:
WR9X489
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
freezer not frezing properly frost buildup
Removed housing around timer. Unpluged and
replaced timer. Defrosted freezer witk small portable heater. Freezer has worked greater since.
Saved a lot on service call.
7 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Gary from ROSETO, PA
Parts Used:
WR55X24064
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Freezer not getting cold enough to freeze ice cream
I took the advice off of your website about the only thing that will fix
the problem is change the run capacitor. I felt assured that I would
have a working refrigerator freezer after making this change. I was
pretty disheartened when it didn`t solve anything. I was not going to
take the new part back out after the small challenge of putting it in.
The next day I found out how to test the old capacitor and it was still
good. I will just have to eat the $49. I did learn not to take advice from
a website even if it seems like a sure thing
8 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Todd from Bainbridge, IN
Parts Used:
WR24X526
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Refrigerator Gasket had split and causing excess sweating inside of refrigerator whick was cauing water to drain out the front door damaging the floor.
Very simple fix. I loosened all screws with a nutdriver, removed old seal by pulling it out from under the retaining plate. replaced new seal and tightened screws.

Great fit!
10 of 17 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Hop from Houston, TX
Parts Used:
WR9X489
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
Refrigerator compartment warm, Freezer cold
This is a old 2000 side by side Kenmore frig bought from sears. left Freezer side was building up ice in the back, while right side was not cool at all. The Defrost Timer was behind the light panel on top in compartment side. Easily remove unit and unscrew things. Works like a champ.
7 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
donald from opelousas, LA
Parts Used:
WR60X187
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers
noise from condenser fan
disconnect the power to the unit. remove the retainer sctrews on the mounting bracket. remove fan motor from unit. using the rerquired tools remove the fan from the old motor and install on the new one. torque the nut until all slack is out then 1/4 turn. reinstall motor assy. and reconnect power. test the system .
10 of 17 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from Cumberland, MD
Parts Used:
WR60X114
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers
broken fan blade in the freezer compartment
Unplugged frige, removed top shelf, pulled broken fan blade off. Replaced with fan blade just purchased from PartSelect. Very simple repair. Orderd and recieved the right part.
7 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Charles from Edison, GA
Parts Used:
WR50X122
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Screw drivers
Refrigerator would begin to lose it's cool and we saw ice caking on the bacjk panel of the freezer section.
We had to empty the freezing section, remove the 4 screws that held the back panel and defrost the coils. Then with the diagram we got from the internet, we removed the defroster and easily installed the new one and put the back panel back on. We did find later that it was still icing over so I ordered the thermostat and we installed it today.
It too was easy to install. We spliced the wires and hooked the new thermostat to the old wires and reinstalled the back panel. Hopefully this will solve the problem for us now.
7 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Eleda from Humble, TX
Parts Used:
WR17X4312
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
refrigerator ice bucket was rusty
My husband just pulled out the defective ice bucket and replaced the new one.
7 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
James from Papillion, NE
Parts Used:
WR2X8702, WR2X8681
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Rubber actuator cover would not shutoff
Replaced the actuator rubber and back plate holder
11 of 21 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Timothy from Orange Park, FL
Parts Used:
WR60X30349
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
stopped making ice
First I turned off the water supply. Then I removed the ice bin and the ice maker by removing 4 screws and 3 electrical connections. This allowed access to the evaporator fan which was not moving. To remove the evap fan I removed two screws that hold the fan bracket. The fan assembly now had to be pushed back and rotated to remove from hole. There are 3 electrical connections that have to be disconnected from the fan, one ground wire that also is connected to the fan bracket and 2 power connections. Installing the new fan was the reverse of the above except the power connections were in a different location and i had to use the extension wires provided with the new fan to have the length needed to make the connection.
7 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Gerald from San Clemente, CA
Parts Used:
WR02X11330, WR17X2891
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Leaky water line to water dispenser
This part (plastic tubing) does not show up under my model of refrig...so I had to look thru the various water lines and pick the one that "looked" right. Luckily, this is the exact replacement part and works perfectly. I removed the lower back panel from the fridge, removed the bracket holding the water line connectors and pressed the outer ring of the coupler up until it released the old water line. I pushed in the new line, made sure it was snug with a gentle pull and ran the line under the fridge up to the existing coupler. I removed the old line from the existing coupler under the front left of the freezer door, and pushed in the new line. I did not need to use the new coupler. If my old line would not have been so brittle and cracked in several places, I could have just cut out the leaking portion and popped the new couple in to mend the line back together. Easy job and we can stop buying bottled water at the store now!
9 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Dean from Park Ridge, NJ
Parts Used:
WR49X10183
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers
rusty ice maker
removed old parts and installed new. went smooth
7 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!