TPX21PRSAWW General Electric Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Laura from Manchester, NH
- Parts Used:
- WR02X11330
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Moving the refrigerator into my new (very old) house we had to remove the doors which resulted in a crimped hose and union
Remove lower front panel, disconnect damaged union from water hose under freezer door, replace with new union, tighten and reattach front panel. No more water coming from under the unit. Ice maker and dispenser features returned to working order!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from Lynnwood, WA
- Parts Used:
- WR51X443
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Refrigerator warm / Freezer iced over
I began by turning off the refridgerator and then removing all of the drawers/bins and icemaker from the freezer.
I removed the three phillips-head screws across the top of the rear access panel. (same height as the light bulb) I then removed the two phillips-head screws from the bottom of the access panel.
I removed the access panel by swinging the left side forward to clear the drawer slides, while keeping the right side back against itsattaching points. (Like a door swinging on its hinges.)
I followed the wire harness from the upper heating element up to its connector and unplugged the defrosting heaters from the plug. I then gently removed the little (just smaller than a tea light candle) thermostat from the top of the coils. (Not far from where the wire connector was.)
I removed two phillips head screws for each heater unit and removed the whole thing as on big assembly.
I installed the new parts from the bottom up, careful not to damage anything. I installed the new thermostat carefully and then reconnected the wire harness. Next I reinstalled the access panel, starting twith the top center screw to hold it in place during the installation of the other 4 screws in the corners.
Lastly, I put the drawers / bins and icemaker back in and turned the refrigerator back on. DONE.
It corrected the problem. THANKS for the Great Customer Service, too!
I removed the three phillips-head screws across the top of the rear access panel. (same height as the light bulb) I then removed the two phillips-head screws from the bottom of the access panel.
I removed the access panel by swinging the left side forward to clear the drawer slides, while keeping the right side back against itsattaching points. (Like a door swinging on its hinges.)
I followed the wire harness from the upper heating element up to its connector and unplugged the defrosting heaters from the plug. I then gently removed the little (just smaller than a tea light candle) thermostat from the top of the coils. (Not far from where the wire connector was.)
I removed two phillips head screws for each heater unit and removed the whole thing as on big assembly.
I installed the new parts from the bottom up, careful not to damage anything. I installed the new thermostat carefully and then reconnected the wire harness. Next I reinstalled the access panel, starting twith the top center screw to hold it in place during the installation of the other 4 screws in the corners.
Lastly, I put the drawers / bins and icemaker back in and turned the refrigerator back on. DONE.
It corrected the problem. THANKS for the Great Customer Service, too!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Scott from Columbus, IN
- Parts Used:
- WR57X10051
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers, Wrench set
water valve leak
This Valve Has 2 Different Size Water Lines Going In To It And They Are Different Diameters.Each Has Its Own Collar That Locks The Lines Into It. Make Sure That You Put The Right Size Collar Over The Line Before You Insert It Into The Valve, Because Once You Put The Line In You Cant Pull It Back Out Without Messing Up The Valve. Make Sure It Is Right Because You Only Get One Shot At It.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jimmy from Palmer, TN
- Parts Used:
- WR50X122
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Defrost Thermostat quit working
Take the back panel off inside of freezer side. Cut the wires off old Defrost Thermostat and strip the ends. Attach the wires of the new one and tighten with wire nuts. Put back panel back on.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Marion from Palm Coast, FL
- Parts Used:
- WR30X10093
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Refridgerator Freezer stoped making ice
Turned off power, removed cover from Ice maker, checked resistance across thermostat for zero (read open), all other switches read proper value (when activated). Ordered and received thermostat. Removed Ice Maker from freezer, removed two screws holding ice tray to Control Assembly. Removed Thermostat and replaced with new one. Applied Silicone Sealant to face of Thermostat for adhesion to ice tray when assembled. Remounted Ice Tray to Control Assembly and remounted in freezer. Works Great...
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- JEFF from HAMPTON, GA
- Parts Used:
- WR60X187
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
fridge quit coolingg / freezing
remove lower back cover - disconnect wires to fan motor - place 6" fan to blow on condenser - fridge began cooling & freezing again - ordered part - part arrived - removed fan motor & bracket - cleaned brackets & fan blade - cleaned lint & dust from condenser compartment (took longer to clean than anything else) - replaced fan motor - replaced cover - was hero with wife ... :-)
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jack from Copperopolis, CA
- Parts Used:
- WR24X525
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Screw drivers
Frost was accumulating in freezer section.
Loosened screws holding old gasket to door. Removed old gasket. Fit new gasket around strips holding gasket in place---this was not easy. Tightened screws.
New gasket corrected problem.
New gasket corrected problem.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Robert from Auburn, AL
- Parts Used:
- WR30X10093
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Ice machine wasnt making ice
First I turned the refrigerator and water line off. Then moved to the freezer section, followed the directions, removed the two screws. Directions state to not remove them but I had to in this case. Unplugged the ice maker and removed it from the freezer. I installed the two mounting screws then tried to plug the electrical connection back in but had to use the adaptor cord furnished in the kit. The cord was a little long but I tucked it in and mounted the ice maker. Turned it on then turned the refrigerator and water back on and in a few hours had ice! Very easy to do!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Kirk E from GRASS VALLEY, CA
- Parts Used:
- WR55X24064
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Fridge keeps cycling on and off and a clicking sound happens every time compressor cycles.
I opened the back panel of the fridge and exposed the compressor. Unplugged existing run capacitor and installed new one with the addition of the sleeve that is stated must be installed around the run capacitor.
Everything I read and on this web site says that based on these symptoms, that the problem is the run capacitor. I searched and search for a part called a start relay which plugs in to the compressor. This run capacitor plugs in to this other part which I take as the start relay.
Installing this run capacitor did not solve the problem. The fridge compressor keeps cycling on and off. Freezer doesn't keep as cold as it should.
Everything I read and on this web site says that based on these symptoms, that the problem is the run capacitor. I searched and search for a part called a start relay which plugs in to the compressor. This run capacitor plugs in to this other part which I take as the start relay.
Installing this run capacitor did not solve the problem. The fridge compressor keeps cycling on and off. Freezer doesn't keep as cold as it should.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- TIM from GRETNA, LA
- Parts Used:
- WR2X4550
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Ice Maker Cap Broke
It took me about 15 minutes to complete the repair, 1st I emptied the ice maker, then I removed 4 screws from the rear of the ice maker tray and took the plastic piece off of the auger. I reversed the steps and put it back together.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ernest W. from Charlotte, NC
- Parts Used:
- WR30X10093
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Screw drivers
Ice maker Stripper lost a tooth
First turn off the power, remove the ice tray, remove the two screws holding the ice maker to the side of the freezer, use the screw driver to gently open the electrical clip for the power cord inside the freezer, remove the complete unit from freezer, bend the old stripper from the holding pin- it is flexible- it will bend, replace the new stripper on the holding pin and bend into the slot to hold it firmly, no water will come out from the fill cup into the freezer, plug in the power cord, mount back to side of freezer, you are done.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- robert from bensalem, PA
- Parts Used:
- WR30X10093
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
broken ice maker
removed 3 screws unplug and remove old unit. install two screws install new ice maker, tighten screws plug in and turn on. had ice in 20 min.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mark from Somers Point, NJ
- Parts Used:
- WR23X37285
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers
Switchlight was broken on tennant's refridge
as described, I used a thin screwdriver to wedge in and pull down existing, broken switch. I was able to pull it down about a 1/4 inch, but wasn't quit able to disegage it until I gripped it with pliers. I then pulled it out, unplugged the old switch, plugged in the new switch, and carefully tucked the wires back into the fridge and snapped the new switch into place.
10 minutes total.
10 minutes total.
Was this instruction helpful to you?
Thank you for voting!
bucket drive shaft disengaged from motor drive
This is a 25 year old unit. The ice bucket had warped over time causing the face plate to move forward of its ideal position pulling the entire assembly out of the drive. Removed dispensing unit face assembly. Removed drive shaft assembly. Replaced all washers. Reversed old broken drive cup. Married old drive cup to new drive cup...lining up drive slots. Drilled 6 ea. 3mm holes evenly spaced around circumference into the face of the old drive cup. Fastened drive cups together in vice and with C clamp...then using phillips head screws installed 3 ea. from opposing entry points on each side of this homemade shaft extender. This "mechanism" increased the effective length of the dispensing shaft assembly allowing for a proper fit of the drive shaft to the motor drive connection. Unit now works perfectly. Total cost @ $40.00 and two hours work which would have taken less than one hour if I had remembered to install the ice bucket seal the first time. New ice bucket would have cost @ $185.00. Home warranty does not cover ice makers or any of the associated parts. DIY...it isn't that difficult.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Lorry from Bentonville, AR
- Parts Used:
- WR57X10051
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
leaking water / icemaker valve
Simple. UNPLUG THE FRIDGE. Remove set screw holding valve to frame, switch hoses one at a time into new valve, switch wires one set at a time from old to new, re-attach the new valve, turn on water , plug in fridge, check for leaks. 2-minute job.
Was this instruction helpful to you?
Thank you for voting!