Handle broken
Removed plate inside door cover and removed old screws and plastic handle. Reassembled.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Kent from NAPA, CA
- Parts Used:
- WB15X10069
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Broken handle
Removed inner trim panel. Bottom screw was visible But upper screw was behind metal frame that trim plate snaps onto Removed that to access screw. Door latch had to be removed to. Not a big deal just be sure spring on latch is reinstalled same way it was removed. Took longer than expected but way cheaper than a service call. Part arrived on time
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Edwin from New York, NY
- Parts Used:
- WB27X10928
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
No heat
Replace the fuses
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Lee from Spartanburg, SC
- Parts Used:
- WB49X10129
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Glass turntable broke when being washed.
Ordered the part on Monday, it was delivered on Wednesday, only paid for standard shipping. All I had to do was put it in, right part, back to new!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Clifford from Springfield, VA
- Parts Used:
- WB10X10021, WB06X10216
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
install new latch and spring in door
removed key pad then removed latch assembly and replaced it with new latch assembly.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Nelia from Streamwood, IL
- Parts Used:
- 6324W1A001L
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
no heat
unplug the unit then pull down , lot of screws are on top. open the cover . you could see the parts that need to replace on the right hand side (heavy side). disconnect wires then test the parts that need to replace by a tester to make sure that it's really broke .then unscrew part and replace .
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Esther from Brooklyn, NY
- Parts Used:
- WB06X10311
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
cover fell apart
removed screw from inside wall. removed leftover board & replaced with new board & screw. good as new!!!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mack from Jacksonville, FL
- Parts Used:
- WB27X10928
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers
No heat.
Replaced the fuse. Result; did not fix the problem.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Benjamin from Anchorage, AK
- Parts Used:
- 6324W1A001L
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Replacement of Magnetron
I UNPLUGGED the microwave and removed the cover, using a phillips and a Torx screwdriver for the machine screws. I set these screws aside, so as not to confuse them with the later encountered screws. I photographed the magnetron to assure proper placement of the 6 phillips machine screws involved in reassembly (marking the the locations on the old magnetron would do as well. I marked the old magnetron "old", to avoid later confusion. I removed the two screws holding the shields to the magnetron. I removed 3 of the 4 screws holding the magnetron to the microwave, leaving one of the top screws. I held the magnetron securely and removed the last screw, pulling out a the part of the magnetron that penetrated the microwave. I installed the new magnetron in reverse order. One problem I encountered was locating one of the six screws, which had been pulled into the old magnetron by magnetism.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Steve from Louisville, KY
- Parts Used:
- WB15X10069
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers
door handle broke off at the attachment points
This was actually easy, first you must remove the top vent piece found above the door, remove 2 screws and the vent pops off, next simply lift the door(straight up) and it should come off. Place the door on a table face down and pry off the plastic outer square using the putty knife, use care since its plastic there are tabs under that will break. Once off locate 6 screws holding the metal bracket that hold the glass in and remove, the bracket will now come out with a bit of prying, again be careful there are several tabs holding the bracket in. Be careful on tiping the door, the inner glass will drop. Once this is removed you have access to the 2 screws holding the old door handle in, in my case I had to hold the old handle with a plier to prevent the piece from turning while I took the screws out(save the screws), after you removed the old simply pop in the new handle using the old screws reattach and reverse the takedown and reattach the door. 15 minutes
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Sam from Chandler, AZ
- Parts Used:
- WB24X10047
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
When trying to run, intermittently, the light would come on but the tray wouldn't rotate or cook. When the door was open, the tray would intermittently rotate.
I pulled out the unit and found 2 interlock switches that are depressed when the door closes. After cycling the door open/closed I found that one of the switches occasionally would stay depressed. The repair was easy (after I took off the panels so I could get to the switch) I simply removed 2 screws that attached the interlock switch assemblies to the main unit. Then I popped out the defective switch and popped in the new one. This did indeed fix my problem.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Gary from Mahopac, NY
- Parts Used:
- WB27X10037, WB06X10216
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
Microwave portion did not work, Halogen lights and fans did.
The primary door latch switch contacts were not closing properly. I broke the latch bracket while removing the switch. It is only a plastic clip that holds the switch in place. I replaced the switch and bracket. The Advantium now works in all modes.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from Pittsburgh, PA
- Parts Used:
- WB10X10021
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
broken latch hook
Removed. Inside frame with putty knife replace new latch attach spring and line up notch of latch in slots. That was the most difficult part replace inside frame. Done!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- William M. from San Diego, CA
- Parts Used:
- WB07X10429
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Old vent grille was broken at the two connecting points.
Unscrewed the two connecting points, cleared out the broken bits of plastic, mounted the new grille and screwed the two screws back in. Easy. Also, the new part arrived very quickly.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Bruce from Daytona Beach, FL
- Parts Used:
- WB15X10069
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Screw drivers
Broken door handle due to heat stress and age 11 yrs.
I removed the plastic perimeter molding from inside of door.You can carefully pry it loose with a narrow putty knife. the door handle screws are located directly behind were the handle attached to the outside of the door. I found that a #2 phillip head screwdriver tip with a large handle for good torque and grip works best however the old plastic post inside the face of the door were turning along with the screws from the opposite side. I used a needle nose plyers to hold onto the plastic barrels in the outside of the door while turning the phillips head screwdriver on the inside at the same time. I found this to be somewhat difficult.You must achieve a good bite with the pliers!
Was this instruction helpful to you?