- Customer:
- Glenn from CHAPPELL HILL, TX
- Parts Used:
- 5304507199
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Followed the instructions that were sent and repair was easy.
Followed the instructions
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Benjamin from Roseburg, OR
- Parts Used:
- 297283900
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
Needed a left hand hinge
The left swing hinge (297283901) that i needed is not available anywhere so I bought the right swing hinge (297283900), used a hydraulic press to pop out the pin and move it to the other hole. After that it was real quick to remove the screws and change out the hinge, changing the swing of the door. It is easiest to remove the top hinge and door first when doing this.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Thomas from GRANBURY, TX
- Parts Used:
- 5304518034
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Freezer not cooling due to icing up of coil.
The timer in this older unit is clearly exposed at the back of the freezer underneath the freezer compartment. It is attached with two Phillips head screws. After the screws are removed, the timer can be unplugged and the new one plugged in. The new timer has an extra flange to allow it to be used on more than one model of freezer. In order to mount the timer in this unit, you have to remove the extra flange by carefully cutting it away from the timer body, in similar fashion to what's depicted in the online video. This will allow you to mount the new timer to the mounting plate using the two screws from the old timer.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Stirling from FORT WORTH, TX
- Parts Used:
- 5304518034
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Coils were freezing up. Defrost cycle not working
First unplug freezer, then disconnected wires from timer.
Removed 2 screws from bracket holding time to freezer.
Attached New part with screws. .The mounting bracket is now part of New time. Reattach wires.
I let coils defrost and then plugged it.
Removed 2 screws from bracket holding time to freezer.
Attached New part with screws. .The mounting bracket is now part of New time. Reattach wires.
I let coils defrost and then plugged it.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Randolph from Edwards, MS
- Parts Used:
- 297309000
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers, Socket set
Evaporator fan not working
Took off cover, unplugged wires, removed old motor, mounted new motor, remounted new motor and replaced cover.
Now need a new control board for same model.
Now need a new control board for same model.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Angela from ORLANDO, FL
- Parts Used:
- 5304507199
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Door wouldn’t stay shut
Purchased gasket from parts plus installed it and door still won’t stay shut without duct tape plus the frost is building up really bad looking for another parts store to get problem fixed
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Gerald from North Little Rock, AR
- Parts Used:
- 5304507199
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Screw drivers
Warm out door gasket.
Had to lossen around 60 screws to allow for the old gasket to be removed. Then I began the process of inserting the new gasket by fitting it into the gasket channel opened when I loosened the 60 screws. I inserted the gasket a little at a time making sure it was properly fitted then I tightened that part and then do the next part until I finished replacing the gasket.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Paul from Buffalo, MN
- Parts Used:
- 5304518034
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Evaporator freezing up. Noticed Ice cream not frozen solid
Notice ice build up on the panel in front of the evaporator coil. Unplugged freezer and removed evaporator panel. Plugged unit back in and checked fan, coil "snap switch" and heater element, all seemed to check out good. Found defrost timer stuck in the freeze position, causing frost to accumulate over the evaporator. Manually rotated defrost timer to the 30min defrost cycle and system went into defrost. Ordered defrost timer and installed (part arrived in 3 days). Freezer works great again. Too bad I ended up throwing 400 dollars worth of meat away. the fix was very simple. Will definitely use PartSelect again. Thank you.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- EDWIN from ELWOOD, IN
- Parts Used:
- 5308000010
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
loud noise fan blade broke,off balance
take 1/4 hex screws out clean out dust ,remove old fan blade replace with new install bolts .
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- hector from los fresnos, TX
- Parts Used:
- 297309000
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Wrench set
When I was ready to instal fan motor, I noticed that there was no thread where I was supposed to screw in the bolts
When i found out there was no thread in brace where bolts were supposed to screw in, I panicked. I thought I would have to send part back or go to a machine shop to make a thread. I called a friend for help and he told me the bolts would make the thread if I just screwed them in. Sure enough, the bolts made the thread and then I just proceeded to instal motor and put refrigerator back together. It was simple.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- George from Gilroy, CA
- Parts Used:
- 297309000
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers, Socket set
condenser fan stop working
Replaced fan. I ordered the fan and received it the following.(-:
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Richard from Clovis, NM
- Parts Used:
- 297309000, 5308000010
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Evaporator Fan Motor was making loud rattling sound.
Unplugged freezer from electrical socket. Removed lower trays from freezer. Removed sound proof stripping from sides of back panel. Removed upper, lower and side screws from back, lower panel using No. 2 phillips screwdriver. Disconnected motor wires from quick disconnect power supply. Removed motor bracket from freezer back using nut driver. Removed motor from bracket using same nut driver. Replaced motor and screws in bracket. reattached quick disconnect. Attached fan blade to motor making certain to push blade on shaft securely. Replaced bracket to freezer back. Replaced back cover. Replaced stripping. Plugged into power supply. Total time 15-20 minutes.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- CRAIG from PRESCOTT VALLEY, AZ
- Parts Used:
- 297309000
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Noisy fan
Remove the cover panel inside the freezer, remove and replace the fan motor (pull fan blades off old motor and push on the new one) and replace the cover.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Joseph from Yulee, FL
- Parts Used:
- 5304518034
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Coils not Defrosting and stopped freezing
Upluged power pulled freezer out from wall removed the two screws that holds the defrost timer unpluged defrost timer pluged new timer in mounted new timer back with the two screws pluged freezer back in and job was complete. Freezer working fine.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mike from Satellite Beach, FL
- Parts Used:
- 297309000
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Fan would not start occasionally
I unscrewed the screws that held the old fan on, disconnected the wiring harness and removed the old fan. I pulled the blades off the motor and put it on the new fan. One thing of note, the screw holes on the new fan weren't threaded. I assume this is by design, so I used the screws to thread the holes before installing it in the freezer. Once I did this, the rest of the installation was easy, just screw it back in and connect the wiring harness.
Was this instruction helpful to you?
Thank you for voting!