Models > 25328262806 > Instructions

25328262806 Kenmore Freezer - Instructions

Jump to:

All Instructions for the 25328262806
1 - 15 of 39
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
Thomas from RIXEYVILLE, VA
Parts Used:
5304507199
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Gasket old and leaking
This freezer has many screws that hold the cover on the back of the door and assist clamping the edge of the gasket in place. Be sure to just loosen the screws 3/4 the way out, use a flat head screw driver to pry the cover from the door in case over time it is stuck to the door. The new gasket will come in a creative box trying not to kink the gasket itself, but there will be some distortion of the gasket when you get it. Put it in the sun or in hot water. I put it in my dryer for 10 minutes. Remove the old gasket, and start at the top of the door to replace the gasket. TIPS: If the screws are backed out enough, there should not be any problem sliding the back part of the gasket under the cover. When on the sides, do not pull the gasket down to make it easier to slide the gasket underneath the cover. This will distort and lengthen the gasket so it will not fit and thin it out so it will not function well. Once the gasket is in place, tighten the screws being sure to feel along the outside edge of the gasket for any bulging that would indicate that portion of the gasket is NOT under the cover properly.
104 of 111 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Wayne from Forest Hill, MD
Parts Used:
5304518034
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Temp alarm sounding and food on top shelves partially thawed
After silencing the alarm, it seemed to be running as normal without any unusual noises, but food was starting to thaw from the top shelf on down and condensation was dripping from the roof. We were able to place most of the food in 2 large ice chests and then the rest in the freezer compartments of 2 fridges we have in the house. I then turned down the temp dial to the coldest setting and let it run for an hour or so; no change.

After researching on the internet, it sounded like our symptoms could be pointing to a defrost timer issue. I pulled the freezer away from the wall, located the timer and used a large screwdriver to slowly advance it. While doing this, at one point I could hear the compressor kick in. I pushed the quick freeze button and let it run for a while. When I checked it in a few hours, the alarm light had gone out and water that I had placed inside was frozen. We took a chance and put the food we placed in the ice chests back in the freezer. Everything was fine several hours later.

I ordered a new defrost timer, it arrived in a couple of days, and replaced the old one with it in a matter of minutes by disconnecting the wire harness from the old timer, removing the 2 screws holding it onto the bracket, screwing the new timer to the bracket, reconnecting the wires harness, and done. It's been a week or so and no problems.
37 of 43 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Nathan M. from Bunnell, FL
Parts Used:
297309000
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Freezer thawing at about 20 degrees
Turned freezer off at themostat and unplugged freezer. Removed 2 screws at front 2 at the back and 2 at the top. Lowered top cover and removed evaporator fan bracket (2 more screws) removed themostat capulary tube( 1 screw and bracket) then unplug fan motor. Removed motor from bracket (2 screws). Put on new fan motor then removed fan blade from old motor and put on the new motor. Remounted fan motor bracket and thermostat capulary tube. Remounted top cover, plugged freezer in the set the thermostat to 4 and freezer is working fine and doing its job. I orderedmotor on a Sunday and it was shipped on Monday and I received said part at 7:pm on Wednesday.
21 of 24 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Eric from SEVIERVILLE, TN
Parts Used:
5304507199
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Frost inside freezer.. Old door gasket leaking.
Pretty straight forward. Loosen all screws "but do not remove" pry door panel from door just enough to slip gasket behind panel. Make sure gasket is seated properly around door.. Tighten all screws snug...

Gasket may not seal right away due to being kinked from packaging, use a little heat on gasket witth hairdryer and push something heavy against door over night. The gasket will straighten out over night.
18 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
don from stony point, NY
Parts Used:
5304518034
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
freezer was stuck in defrost mode - - stayed at 30 degrees
slid freezer away from wall - - bottom left hand corner was the frost timer - - removed two philip head screws - - unpluged timer and installed new timer - - turned timer past first click to a little past second click (freeze cycle) - - slid freezer back FINISHED - - YOU GUYS ARE THE BEST WITH YOUR WEB PAGE AND HELP!!!!! Next day freezer was at 0
20 of 26 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Harry from Rockwall, TX
Parts Used:
216954235
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
Refrigerator was trying to cycle compressor on, but each time the compressor started, it would stop due to the thermo breaker would open. The fans continued to run, so I figured it was starter relay.
Moved the refrig. out, removed the four screws that held the lower access panel in place. Disconnected the power cord. Removed the retainer clip wire and pulled the relays from the compressor socket. Separated the relays and installed the secondary relay on the new starter relay. Reinstalled the starter relay assembly into the compressor socket. Plugged the power cord in and listened for the compressor to cycle on. It cycled on and continued to run. Turned the power off and reinstalled the retainer clip wire. Reinstalled the access panel and plugged the power back in and left the refrig. run overnight. Checked temperature and also started the ice maker. Everything was normal by morning.
16 of 19 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Cheryld from Florence, SC
Parts Used:
5304518034
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Freezer was getting all iced up...
Watched the defrost timer to see that it wasnt moving, looked the part number up on your site and it even had a picture of it so I knew I was getting what I needed, ordered it when it came I took out the screws holding it in place unplugged old one and plugged in the new one, freezer works like new... :))
16 of 19 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Steven from Alamogordo, NM
Parts Used:
5304518034
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Freezer would over temp and decrease cooling efficiency
One day my freezer's overtemp light/warning came on. I knew the compressor was working properly (as it was still running) and that there were no leaks.

I was able to research about how this freezer worked and learned of this mechanical timer on the back of the freezer. It turns on/off the defrost mode of the freezer.

I manually turned the knob on the back to see if I could get the freezer to defrost. Turns out the timer was no longer working and when I manually ran the defrost, the freezer started to freeze again.

I just replaced this part and my freezer is working like norma.. Simple as all it takes is a few screws and you are done.
15 of 17 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Raymond from San Antonio, TX
Parts Used:
216954235
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers, Screw drivers, Wrench (Adjustable)
Compressor would not start.
After earlier determing that the starter switch was at fault, I removed the cardboard lower back panel, shut off water to the ice maker, removed water line. The plug to the compressor containing the switch and capacitor was held on by a spring clip, removed clip pulled wires from old switch (Here needle nose pliars are handy as the spade clips on the 2 wires have their own locking clips) replaced switch and all wiring, tested unit and problem solved.
15 of 19 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
James from Biloxi, MS
Parts Used:
5304518034
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Freezer was not cycling and started freezing up around the compressor but was not able to freeze inside the box.
I knew that the problem had to do with the timer so I went online and looked at the schematic diagrams on Partselect and identified the part that should handle the problem. I ordered it and it arrived fairly quickly. It took a Phillips screw driver and about fifteen minutes to remove the old part and replace it with the new one. Very easy repair. It is working as it should now.
15 of 20 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Richard from CARY, NC
Parts Used:
5304507199
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Freezer is 17 yrs old so needed a new gasket. The results were poor since the new gasket would not allow the door to seal.
Removed the numerous screws and took the door panel off. Cleaned and dried it. Replaced the insulation and hung the penal with 2 screws at the top and sides. Started to fit the gasket under the edge of the panel and put on the screws as I went across the top then down the sides finishing across the bottom. Perfect fit but could not get the door to seal at all. Went out and bought a new freezer(did I say it was 17 yrs old?!?!).
13 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Gary from SEQUIM, WA
Parts Used:
5304518034
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
Freezer would not run; no electrical power to the compressor
Looking on-line at your diagnostic for this problem, I saw the most common part to cause this problem was the start capacitor, so I purchased one & installed it with no positive outcome. I then purchased the next recommended part which was a defrost timer & installed it with no run again. Frustrated, I looked at another diagnostic web site that claimed 90% of the time the problem is caused by the cold control thermostat. I tested mine and it tested bad, so I bought a control elsewhere, since your site did not list a PN for that device. I installed the new control and the freezer started up correctly. Looking at the wiring diagram for these parts, I see the start capacitor and defrost control are downstream of the cold control thermostat, and to my mind should have been the first part recommended for testing versus the parts I bought, so I am somewhat disappointed in the diagnostics on your site, where I spent about $80 for parts that were functional.
9 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
mary from Hallettsville, TX
Parts Used:
5304507199
Difficulty Level:
A Bit Difficult
Total Repair Time:
More than 2 hours
Tools:
Screw drivers
Gasket shipped in box, could never get wrinkles out, freezer leak, ice formed on for and freezer,. Could have saved $150.00 + by not trying gasket.
Purchased new freezer.
10 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mike from Los Banos, CA
Parts Used:
297309000
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
Evap fan motor intermitant
Removed evap cover from Commercial Refrigerator. Removed mounting screws from Evap motor mount. Replaced evap fan motor. Repositioned. Reinstalled evap cover. Tested . This motor was hard to find locally. Glad I called.
11 of 16 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Tom from Argyle, WI
Parts Used:
5304518034
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Freezer not defrosting
Replaced defrost thermostat and defrost timer on my commercial Kelvinator freezer. Took out screws inside freezer compartment that hold panel at top inside freezer.Once the screws were removed I pulled out the thermostat dial so the panel was free to drop down and expose coils to the freezer that were located in the top rear of the inside freezer compartment.The defrost thermostat was located on the top of the coil to the top left as you face the inside of the Kelvinator KFS220RHY1 freezer. Very easy unplug old and plug in new defrost thermostat. Also replaced timer located in the back side of the freezer down near the middle of the bottom of the freezer near the compressor. There were two nuts holding the timer in the back of the freezer once I took those out I just unplugged the old timer and plugged the new timer in ....very simple fix. I have only run my freezer for a week since I replaced both parts but so far all is working well.
7 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the 25328262806