- Customer:
- Thomas from Salisbury, NC
- Parts Used:
- 5221ER1003A, 5220FR2006H
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Screw drivers, Wrench (Adjustable)
found a leak in the cold water inlet valve- one of the seat gaskets was bad
found a slow leak in one of the valve seat gaskets and decided to replace the entire valve (also did the hot inlet as well just in case). Unplugged unit, detached water hoses (replaced these as well), moved the washer out about 12" from the wall. With Phillips head removed the washer top. With pliers removed the hose clamps off the valve heading to the detergent dispenser (be sure to keep track of what hose goes to what nipple). Detached electric clip from each solenoid. Using Phillips head removed the valve. Use reverse order to install new valve. Ran the unit through a long cycle with the top off to ensure there were no leaks.
Was this instruction helpful to you?