Customer:
Jerold from Schaumburg, IL
Parts Used:
279834, 279834
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
The burner fires up the first time but then never fires again causing no heat
The hardest part is figuring out how to get the unit open. You have to take out the brackets that appear to hold on the timer section and you have to remove the screws under the lint filter. Once you have the top off then you remove the screws that hold the front panel on from the inside. I decided not to remove the drum it seemed like a lot of hassle, instead I went down and got a right angle screwdriver, the terminal valves are in the front of the unit and you only have to remove 2 screws to remove the retainer which holds them both in place. The drum is in the way so you can't use a regular screwdriver and the right angle is a bit slow going but I think it is actually faster than removing and replacing the drum for a novice like myself. Replacing the coils took about 2 minutes and then reassembly another half hour. But the Dryer works great again and for $70 it was well worth it.
Was this instruction helpful to you?
Thank you for voting!
Customer:
donald from anchorage, AK
Parts Used:
279834
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
dryer heats up for seconds and stat cold
open the back pannel and use multimeter to check the wirings and everything checks ok. open the bottom front panel of the dryer and turn the dryer on. the igniter works and the flame came out for seconds and dies off. the igniter keep coming on, but it seems that the gas was not coming out. i checked the gas line valve and it was open. i had a good idea it wasn't the wiring or the gas line, it must be the coil-valve,(safety coil), that letting the gas flow. i order the parts, it came sooner, which is good, and it took me less than 10 minutes to install, and i only use a philip screw driver. i thank you for sending me the right part in short period of time.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jaime from Glendale Heights, IL
Parts Used:
279834
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Socket set
dryer didn't heat up
Pretty much just followed the installation video. Took dryer apart and just put everything back the way it was.
Was this instruction helpful to you?
Thank you for voting!
Customer:
michael from Pueblo, CO
Parts Used:
279834
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
dryer wouldn't heat
Watched video. Made this a very easy repair.Will use this site for next repair.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from Adkins, TX
Parts Used:
279834
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
burner wouldn't relight after 1st or 2nd heat cycle; in other words heat faded out; solenoids measured correct resistance, but would not open the valves once they heated up
removed frt cover & drum, replaced solenoids, cleaned the unit interior
Was this instruction helpful to you?
Thank you for voting!
Customer:
Edward from Benton Harbor, MI
Parts Used:
279834
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
no heat
the repair was an easy fix, I removed the two screws from the brackets holding the coils, disconnect and removed them installed the new coils connected plugs turned on dryer and I got heat not bad at all thank you for the help
Was this instruction helpful to you?
Thank you for voting!
Customer:
Timothy from Burlington, WI
Parts Used:
279834
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
timer dot working/ heat not staying on
unscrewed the 2 screws holding the coil's in place took wires off one coil at a time tested coils with ohm meter found the two wire coil was bad replaced and scered the bracket that holds the coils back in place.PartSelect gave me a list of what was causing the problem and what the % of what was the cause,this helped alot Thankyou PartSelect
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jane from Cohasset, MA
Parts Used:
279834
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
The dryer failed to heat up
I'm a 65-year-old woman with no prior appliance repair experience. I learned on the web that 30% of the time, the failure-to-heat problem is caused by the valve coil, and 30% of the time, it's the cycling thermostat. So I ordered both parts. I watched installation videos on the web. The valve coil was accessable through a front port on the dryer so I started there. I had to go buy a stubby screwdriver because access to the screws was limited. From there, it was easy to take out the old valve coil and install the new one. Just 5 minutes. I plugged in the dryer again, turned it on, and it worked.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Carol from Ada, MI
Parts Used:
279834
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers, Wrench (Adjustable)
Was not drying well
I first replaced the temperature sensor. That did not help and when doing investigation when thr drier was warm I found the vallve would open and close if I touched the coils
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jay from South Bound Brook, NJ
Parts Used:
279834
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
Flame would go out after start up. The Igniter would glow not light
Repair itself was not hard, Pop top, unscrew front panel and pull forward to get at the coils under the drum. --THIS IS THE KEY POINT i ENCOUNTERED: I tested the coils and the resistance was right according to the schematic. But still the flame would go out after while. --on a whim I pulled the front cover and tested the coils immediately after the flam wouldn't re-light.---When the coil got warm, it would open (no continuity). When it cooled down again the correct continuity would return. Replaced the coil and no more problem
Was this instruction helpful to you?
Thank you for voting!
Customer:
john from garden city, NY
Parts Used:
279834
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers
heat cycle runs once then does not come back on
follow Steve the repairman's instructions they were very good
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from Hazlet, NJ
Parts Used:
279834
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
no heat. only lights first time.
Replaced cycling thermostat but wasn't the problem. Tested the coils with ohm meter & found no read on the one with 3 prongs. Replaced both anyway. Top of dryer is held on with 2 clips, popped it off to reveal 2 screws on front panel. Bottom is held by 2 clips must lift straight up. Removed bracket that holds the coils in & removed wires. They only go on 1 way. Installed new coils , no more problems.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Darwin from Meriden, CT
Parts Used:
279834
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers, Socket set
I have a Maytag gas dryer, it runs but it dud'nt get hot....
First I opened the back panel & check the fuse with multi meter tool ( put in ohms & set it in 200K) & the fuse is Ok, try to run the dryer while looking in the flame dock & the burner starts & had a fire till about 2-3 mins. & flame comes off, what I did is I open the front door to access into the gas burner, check gas valve coils with multi meter tool for continuity & found out that one of the coil doesn't have continuity. I ordered a pair of coil that is located on top of the gas valve on this site & unexpectedly it came in the next day, WOW! that's a fast delivery I was very pleased w/ the service, come home from work & installed it right away & it took me 5-10 mins. Put back everything & try to run it & it works properly. So happy with & my wife as we'll, thanks for the great fast delivery.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Diane from Monroe, MI
Parts Used:
279834
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers
Gas valve will not light
Replaced bad coils
Was this instruction helpful to you?
Thank you for voting!
Customer:
TONY from NEW EGYPT, NJ
Parts Used:
279834
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
Lost heat after a few minutes
Pried the top up, disconnected the door switch, removed two top screws holding the front panel, disconnected the spring and removed the front panel. Removed the screws and retainer holding the coils, replaced both coils and reversed the process. This was the third component I replaced to solve the problem....a cheap multi-meter and some testing would have solved the problem sooner. We now have the whole heat cycle.
Was this instruction helpful to you?
Thank you for voting!