IX5BBEXDS00 Whirlpool Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Ricky from Philadelphia, PA
- Parts Used:
- 4317943
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
stop making ice
1.removed 3 nut screws-2 on top &1 on bottom.
2.unplug ref. from outlet.
3.unplug the wires from ice maker to ref.
4.remove ice maker
5.rinse new ice maker
6.plug ice maker to ref. using included wires
7.screw 2 top nut screws first then the bottom.
8.plug ref. back to outlet
9.made first ice in about 2-3 hours
2.unplug ref. from outlet.
3.unplug the wires from ice maker to ref.
4.remove ice maker
5.rinse new ice maker
6.plug ice maker to ref. using included wires
7.screw 2 top nut screws first then the bottom.
8.plug ref. back to outlet
9.made first ice in about 2-3 hours
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Cuong from Camarillo, CA
- Parts Used:
- 8201515
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Screw drivers
Ice maker just stpooed making ice
The troubleshooting time takes about 20 to 30 minutes. After checking out the solenoid (valve water), the water line, and the electronic board (emitter/receiver) are working fine. The only thing left is the ice module. I called Partselect and talked to a sale rep to make sure I get the right part, and the lady was so helpful by sendind the picture of the part so I can review before ordering it. I received the part in 3 days ( normal shipping) and did the folowings:
1) Unplugged the power cord from refrigerator.
2) Removed the ice module by removed a 1/4" screw from under the right side of the icemaker that retains the icemaker and a “U” plastic clamp and then pull out the whole unit it from the track.
3) Unplugged the cable connected to the ice maker.
4) Using the phillips screw driver to remove the 3 screws. Carefully pulled out the ice module and installed the new ice module.
5) Put the ice maker back to the freezer, plug the cable back to the ice maker and put the clamp and tighten the nut.
6) Plugged the power cable back to the wall.
The first ice I got in an hour and a full bucket of ice in less than 24 hours. I spent less than $80 for the whole thing. Thank you so much Partselect for the great service and the stories posted, it really helped me to get it done.
1) Unplugged the power cord from refrigerator.
2) Removed the ice module by removed a 1/4" screw from under the right side of the icemaker that retains the icemaker and a “U” plastic clamp and then pull out the whole unit it from the track.
3) Unplugged the cable connected to the ice maker.
4) Using the phillips screw driver to remove the 3 screws. Carefully pulled out the ice module and installed the new ice module.
5) Put the ice maker back to the freezer, plug the cable back to the ice maker and put the clamp and tighten the nut.
6) Plugged the power cable back to the wall.
The first ice I got in an hour and a full bucket of ice in less than 24 hours. I spent less than $80 for the whole thing. Thank you so much Partselect for the great service and the stories posted, it really helped me to get it done.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Duncan from Metairie, LA
- Parts Used:
- W11384469
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
The Switch Broke...Absolutely Fell Apart.
I simply removed the old switch using 2 small screwdrivers and the old switch case popped out. I then upluged the wires from the old switch and reversed the process. Didn't take longer than 5 minutes begining to end! Thank you for the great service! Duncan quaid
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from NASHUA, NH
- Parts Used:
- 4317943
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
Ice maker stopped working. Thought it might be the timer. Actually teflon coating coming off.
Removed the ice maker. Used a small mirror (wife's make up mirror) to find the screws. Inspected and found most teflon coating missing. Ordered new ice maker and installed. Works perfect.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- gary from DES ALLEMANDS, LA
- Parts Used:
- WPW10383615, W11227949
- Difficulty Level:
- Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Screw drivers
Freezer freezes up.
Pulled drawers and freezer door off. Removed ice maker and fan cover. Then the back wall cover. Unplugged old thermistor and removed. Put new one in place and reinstalled everything. Works like a charm.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Stephen from Jacksonville, FL
- Parts Used:
- W10316760
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- More than 2 hours
- Tools:
- Nutdriver, Screw drivers
Lower Freezer worked fine, but upper refrigerator would not cool.
I first replaced the lower (freezer) evaporator thermistor based on recommendation from other feedback, however that did nothing to resolve the problem. I subsequently discovered a diagnostic document hidden under the upper right door hinge, which helped me narrow the problem down to the upper (refrigerator) evaporator fan motor. After replacing the fan motor, my refrigerator is up and running again. The only challenge was accessing and removing the access panel(s) and air column. Once those were removed, replacing the fan motor was simple.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Charles Allan from GARDEN GROVE, CA
- Parts Used:
- WPW10383615
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Freezer was defrosting at the wrong temperature resulting in excess frost and ice. Poor cooling!
Removed all food! I used storage boxes insulates with blankets and a bit of dry ice in the boxes to keep the food cold.
Removed bottom bin and shelf
Removed bottom cover and fan shroud, this exposes evaporator coil and the thermostat. I had to defrost the evaporator and thermostat, they were completely encased in ice.
Thermostat is clipped to the evaporator coil, simply pry it off and removed it from the wire harness. Easy! Thermostat has a connector!
Installed new thermostat in the same location as the old one. Connected it to the wire harness and replace the bottom cover.
Turned it on and it seems to be working fine, now three weeks after repair.
Removed bottom bin and shelf
Removed bottom cover and fan shroud, this exposes evaporator coil and the thermostat. I had to defrost the evaporator and thermostat, they were completely encased in ice.
Thermostat is clipped to the evaporator coil, simply pry it off and removed it from the wire harness. Easy! Thermostat has a connector!
Installed new thermostat in the same location as the old one. Connected it to the wire harness and replace the bottom cover.
Turned it on and it seems to be working fine, now three weeks after repair.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from Dublin, NH
- Parts Used:
- W10311524
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
air filter needed replacement
pulled the top shelf and poped open the door and replaced the filter
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Hans from OGDEN, UT
- Parts Used:
- WPW10475495
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Socket set
Raise side of fridge and slide 2x4 under side with broken wheel.
Remove back side cardboard access cover. About 6 dcrews need to be removed. Remove 9/16” bolt and lower compressor tray frame down to slide out wheel axel. Place wheel in slot and replace axel. Lift compressor tray and replace 9/16” bolt. Replace cardboard cover. Remove 2x4.
Was this instruction helpful to you?
Thank you for voting!
linking water out of underneath of bottom freezer
took back off refrigerator read directions that was sent with parts and replaced the wore out drain nozzle . Even this 70 year old woman could do this her self and changed air filter in refrigerator also
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Tom from FENTON, MO
- Parts Used:
- WPW10448874
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers
Refrigerator and freezer not cooling
It was easy to replace the start and run capacitors. But did not fix my problem, also replaced the evaporator fan still not fixed. Pulled refrigerator out of RV and ordered a new one.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Scott from ONEIDA, NY
- Parts Used:
- EDR1RXD1
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
Filter indicator light red
Found the filter door in toe kick under freezer door. Opening the door ejected the old filter. Direction indicator arrows were found on inside of filter door, rotation of filter to match arrows important. Pushed new filter in to stop, closing door completed insertion of new filter.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ray M from Cave Creek, AZ
- Parts Used:
- WPW10383615
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
No Defrost Mode After Heating Element Replacement
Super simple job. Unplug freezer. Have a hair dryer handy to defrost while you have unit open. Remove food from the bottom two shelves and floor of freezer. Remove mid plastic cover removing three screws. (All screws are same so mixing them is no big deal.) Use drill-driver or screw driver to spin out six screws on lower back plate. Remove plate. Thermistor is on left side of the cooling tubing. Use hair dryer to melt ice if necessary. Un-clip thermistor power connection, and unsnap it from tubing. snap new thermistor on cooling tube and hook up wiring. Ensure plug fits together correctly and snugly. If heavy icing exists, use hair dryer to melt ice on coils and through fan. Ensure water drains out of drain pan under coils. Wipe up as much ice melt as possible to prvent re-frosting upon start-up. Replace lower panel and six screws. Replace mid-panel cover and three screws and replace shelves. Done! Plug freezer back in and expect 30 second delay before unit will start up.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Sung-Su from BISMARCK, ND
- Parts Used:
- W11396033
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
Broke the Rocker Switch in Fridge side
Popped out with butter knife and unplugged 3 prong connector and reversed with anew switch.
But, unfortunately it got broken again exactly same way as before.
So, I ordered same switch again for 2nd time.
Maytag should recall that Rocker Switch and build with better materials.
But, unfortunately it got broken again exactly same way as before.
So, I ordered same switch again for 2nd time.
Maytag should recall that Rocker Switch and build with better materials.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Terry from WARMINSTER, PA
- Parts Used:
- W11396033
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Broken light switch
Watched video. Unplugged refrigerator and popped out switch. In plugged connector and pushed switch in place. Plugged in refrigerator and the light worked
Was this instruction helpful to you?
Thank you for voting!