Models > GX5FHTXVY09 > Instructions

GX5FHTXVY09 Whirlpool Refrigerator - Instructions

Jump to:

All Instructions for the GX5FHTXVY09
46 - 60 of 422
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
Phil from GREENFIELD, IN
Parts Used:
W11395888
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers
Remove the water filter to install the bypass cap
Lower the filter bottom housing to gain access to the filter. Unscrew the filter and install the bypass cap. Secure the lower filter housing to the top assembly.
11 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
dennis j from TOMAHAWK, WI
Parts Used:
WPW10503278
Difficulty Level:
Very Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
frig would not get cold
I watched video for repair and it went just like it showed. piece of cake
10 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
BRIAN from DEER PARK, NY
Parts Used:
W10884390
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Socket set
Ice maker stopped working
I tested the ice maker first and got no response. So I bought the new ice maker and unplugged the connector in the back, loosened the 2 screws up top and took the bottom screw out. I took out the old one and then plugged the new one in and hung it back on the 2 loosened screws and put the bottom screw in and tightened the screws. I have to say it’s working great! Have plenty of ice again. Saved a lot of money by doing it myself. Buy your original model number part from Parts Select.
9 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Thomas from SPRINGFIELD, MO
Parts Used:
W10830162
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Right side door gasket split open
First, selecting the right part is more difficult than the repair. My Kenmore is an outdated model actually manufactured by Whirlpool.

Once I got the part I relaxed the gasket with a hair dryer - an important step suggested by PS. I then took old of the old gasket and removed it. The new one fits in the channel. Just press and make it is completely installed and flush.
9 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Lori from Chuluota, FL
Parts Used:
W11384469
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
There was no light on in refrig area
Just replaced the switch, but unfortunately that was not the problem; nor was it the bulb....so I am back to square one.
But Parts Select is a great place to order from. Thank you.
12 of 19 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
William from EXTON, PA
Parts Used:
WPW10503278
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
freezer no staying cold
Replaced the electronics board. Fairly easy job. Video helped enormously. Programing is awkward.
9 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Roderick from NEWTOWN, PA
Parts Used:
WP2300868
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
Leaking water tube connector/union
Received the union I ordered, then discovered that the tubes were different sizes, so I had the wrong part. I had read elsewhere that it was necessary to trim the two ends of the tubes with a box cutter to stop the leaks - I did this, and the leaking stopped. I was then able to go to a local hardware store and get a 5/16 to 1/4 union and replace it. The leaking is stopped, and the water supply in the door is now working like new. No problem with partselect, but I did buy a caliper so that I can check tube diameters if I ever have a similar problem! This is a great site to find instructions - well worth the time to search!
9 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Russell from ROCK HILL, SC
Parts Used:
W10443320
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
replace freezer door gasket
first pressed in two bottom corners then used fingers to press in bottom section,pressed in two top corners then pressed in both sides using fingers followed by pressing in top section using fingers.VERY EASY !
8 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Darrell from BURLESON, TX
Parts Used:
WP13005401SP
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
beverage sleeve would allow drinks to fall out.
Followed video which this site had on the page my part was on. Made repair very easy.
8 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Richard from West Warwick, RI
Parts Used:
W11396033
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
broken light switch
followed the instructions provided and that's it!
12 of 20 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Kenneth from Newton Grove, NC
Parts Used:
W11396033
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Light switch rocker broke, disabling freezer internal light, water dispenser, and ice dispenser
Very simple. Matched female plugs with respective male color coded prong; pushed together then inserted unit in slot of freezer sidewall and rotated into position...job done.
10 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from Rocky River, OH
Parts Used:
WP627985
Difficulty Level:
Difficult
Total Repair Time:
More than 2 hours
Tools:
Pliers, Screw drivers, Socket set
replacing thermostat did not help
Icecubes came out half-way, and refrooze. I figured out, that the melter does not work (HEATER in the icemaker) Voltage measured 105V no load. Studied the Internet, and folloved an advice: shorted the back wire and the blackwire with white stripes.these go to relay contacts. It seems, that the relay contacts are no good on Infrared receiver boaed. I turn off manually the icemaker, when needed
10 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Fidel from Forest, MS
Parts Used:
WPW10128551
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Refrigerator wouldn't cool
First I removed the six screws from the cover. I then disconnected the two wires and pulled the small motor out with its base and removed two screws that hold it in place. I then changed the old one for the new one and set it back in its place. I then set the cover back and turned it on. I was happy again.
10 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from ROSEBURG, OR
Parts Used:
W10619951
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
The frost free drain behind the freezer compartment clogged and water collected in the bottom of the freezer and eventually came out the door on the right front of the refrigerator.
The other instructions and the video provided by Parts Direct are pretty good with instructions, but they omit two steps. First, if you have an ice maker, you will need to unplug the connector on the back side of the panel you remove at the back of the refrigerator to access the drain tube. Just unplug it and you can move the removed panel to the side without disconnecting any of the water lines. Second, the instructions say to just reconnect the "bottom end" of the new p-trap drain to the drain pan at the bottom of the refrigerator. They don't tell you there are two places to connect the new p-trap to the drain pan. The original tube/trough connected to the one at the back of the drain pan on the left (viewed from the rear of the refrigerator). At first, it looks like the new p-trap won't reach to it for the connection, but if you look closer, there is another connector to the right of the original one that the p-trap connects to properly. Replacing the drain trough with the new p-trap was actually pretty easy and would only take about a half hour. Add another half hour to give the refrigerator coils a good cleaning as they will need it now that you can reach them. The real time consumer, 3 to 4 hours, is needed to use a hair dryer to melt and clear the ice from the condenser at the back of the freezer so the water can drain. Just take your time and all the ice will eventually melt and drain out so the new p-trap will work properly.
8 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jorge from Miami, FL
Parts Used:
WPW10662129
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
The Freezer defrosted and everything on the top and the bottom spoiled
i had used your web site before and i read several problems that your readers had. i went to the back of the unit, removed the bottom cover and right there the i found the run capacitor and i chaged it. since i had only ordered this part to save money i went back and ordered the Start Device which when i took it off it was completely burned. the replacement part came labeled with 2 different compressor #, so i picked the one that i had and unpluged each wire. the part may differ from the one that it's in the unit but it worked when i pluged everything back on. it also helps to take a picture of everything before removing the wires in case you have to leave it and come back later. i hope to use this refrigerator another 10 years. thank you all for your help.
10 of 16 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the GX5FHTXVY09
46 - 60 of 422