36359577991 Kenmore Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Andrew from Decatur, AL
- Parts Used:
- WR51X443
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Top of refrigerator and freezer are warmer than bottom. Also, a large amoutnt of ice build up in the back of the freezer.
**Before you order a new part make sure you get the FULL model number off of the back of the refrigerator**
To even get to the back panel I had to melt the ice in the back of the freezer with a hair dryer. Once the ice was gone I removed 5 screws that held the panel that covers the coils. I melted more ice from the coils. I disconnected the connector for the old heater wiring harness and pooped the thermosat off. Then, removed the screws that held the heaters (2 per heater). Installed new heaters and connected wiring harness. Snapped new thermosat on. Replaced coil cover and plugged it back in.
To even get to the back panel I had to melt the ice in the back of the freezer with a hair dryer. Once the ice was gone I removed 5 screws that held the panel that covers the coils. I melted more ice from the coils. I disconnected the connector for the old heater wiring harness and pooped the thermosat off. Then, removed the screws that held the heaters (2 per heater). Installed new heaters and connected wiring harness. Snapped new thermosat on. Replaced coil cover and plugged it back in.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Richard from Quakertown, PA
- Parts Used:
- WR51X443
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Socket set
would not defrost
First I removed the light cover, one screw. Then I removed the rear coil cover, three Phillips screws and two hex head screws. I then defrosted the coils and removed the old defrost element and wiring harness, two hex head screws held in the element, wiring harness just unplugs. I the installed the new defrost coils ( new one had two coils but had a previously designed area for the second element ) and ran the wiring harness up to where the plug was. I then reinstalled the coil cover plate, and light guard and started the refridgerator. Frige runs like new. Thank you PartSelect for the extremely propmt delivery and the correct part. part
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Bill from Columbiana, AL
- Parts Used:
- WR9X489
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
freezer not frezing properly frost buildup
Removed housing around timer. Unpluged and
replaced timer. Defrosted freezer witk small portable heater. Freezer has worked greater since.
Saved a lot on service call.
replaced timer. Defrosted freezer witk small portable heater. Freezer has worked greater since.
Saved a lot on service call.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Paul from Palmdale, CA
- Parts Used:
- WR51X443
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
freezer coil iceing up
removed freezer racks and back panel. removed and relaced defrosting harness. reassembled compartment
PartSelect rocks! easy to locate needed parts. price is fair and quick shipping. saved me $$$$
PartSelect rocks! easy to locate needed parts. price is fair and quick shipping. saved me $$$$
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Todd from Bainbridge, IN
- Parts Used:
- WR24X526
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Refrigerator Gasket had split and causing excess sweating inside of refrigerator whick was cauing water to drain out the front door damaging the floor.
Very simple fix. I loosened all screws with a nutdriver, removed old seal by pulling it out from under the retaining plate. replaced new seal and tightened screws.
Great fit!
Great fit!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Hop from Houston, TX
- Parts Used:
- WR9X489
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
Refrigerator compartment warm, Freezer cold
This is a old 2000 side by side Kenmore frig bought from sears. left Freezer side was building up ice in the back, while right side was not cool at all. The Defrost Timer was behind the light panel on top in compartment side. Easily remove unit and unscrew things. Works like a champ.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- donald from opelousas, LA
- Parts Used:
- WR60X187
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
noise from condenser fan
disconnect the power to the unit. remove the retainer sctrews on the mounting bracket. remove fan motor from unit. using the rerquired tools remove the fan from the old motor and install on the new one. torque the nut until all slack is out then 1/4 turn. reinstall motor assy. and reconnect power. test the system .
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from Cumberland, MD
- Parts Used:
- WR60X114
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers
broken fan blade in the freezer compartment
Unplugged frige, removed top shelf, pulled broken fan blade off. Replaced with fan blade just purchased from PartSelect. Very simple repair. Orderd and recieved the right part.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Eleda from Humble, TX
- Parts Used:
- WR17X4312
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
refrigerator ice bucket was rusty
My husband just pulled out the defective ice bucket and replaced the new one.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Charles from Edison, GA
- Parts Used:
- WR50X122
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Screw drivers
Refrigerator would begin to lose it's cool and we saw ice caking on the bacjk panel of the freezer section.
We had to empty the freezing section, remove the 4 screws that held the back panel and defrost the coils. Then with the diagram we got from the internet, we removed the defroster and easily installed the new one and put the back panel back on. We did find later that it was still icing over so I ordered the thermostat and we installed it today.
It too was easy to install. We spliced the wires and hooked the new thermostat to the old wires and reinstalled the back panel. Hopefully this will solve the problem for us now.
It too was easy to install. We spliced the wires and hooked the new thermostat to the old wires and reinstalled the back panel. Hopefully this will solve the problem for us now.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Gerald from San Clemente, CA
- Parts Used:
- WR02X11330, WR17X2891
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Leaky water line to water dispenser
This part (plastic tubing) does not show up under my model of refrig...so I had to look thru the various water lines and pick the one that "looked" right. Luckily, this is the exact replacement part and works perfectly. I removed the lower back panel from the fridge, removed the bracket holding the water line connectors and pressed the outer ring of the coupler up until it released the old water line. I pushed in the new line, made sure it was snug with a gentle pull and ran the line under the fridge up to the existing coupler. I removed the old line from the existing coupler under the front left of the freezer door, and pushed in the new line. I did not need to use the new coupler. If my old line would not have been so brittle and cracked in several places, I could have just cut out the leaking portion and popped the new couple in to mend the line back together. Easy job and we can stop buying bottled water at the store now!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Eugene from Palm Springs, CA
- Parts Used:
- WR02X11330, WR17X2891
- Difficulty Level:
- Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Screw drivers
Water line was broken at the bottom of the freezer door.
There is no access to the inside of the door to replace the water line. I was able to insert a 1/4" drip line barbed connector into the old line at the base of the door and then connect that to a piece of the plastic tubing which I then connected back to the original water supply tubing with the 5/16" union. It took three attempts to get the tubing through the bottom hinge without a crimp in it. It's best to have a second person to hold the door while you "fish" the tubing through the hinge.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Michael from NEW BERN, NC
- Parts Used:
- WR07X10099
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Pliers, Screw drivers
Refrigerator and freezer were not cooling
Vacuumed the area around the compressor, removed the PTC relay switch cover, pried the broken relay switch off the unit with a screw driver and replaced with the new relay switch. Replaced the backing of the refrigerator and tested, within minutes the work was confirmed.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Wilbur from Waynesboro, PA
- Parts Used:
- WR13X10020
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Wrench (Adjustable)
Freezer hinge was worn
Shut off water and disconnected at factory joint at bottom hinge. Unplugged the electrical at the top hinge. Removed the door and installed new bottom hinge and cam assembly. Reinstalled the door and hooked water and electric back up. Part worked fine.
Was this instruction helpful to you?
Thank you for voting!