Customer:
David from Murfreesboro, TN
Parts Used:
WP2198202
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
Fridge side freezing everything.
The fridge side would freeze everything regardless of setting. First, unplug the unit. Remove control knobs and pry off the face plate which is snapped on. Remove the four nuts holding the control box to the top of the fridge. Note there is a mettle rod and the thermostat sensor lead inside a clear plastic tube leading from the control box to the back left corner of the fridge. Remove their cover (one screw). Under this cover in the back is the vent assembly screw. Remove it. On the freezer side, you also have to remove the light cover (snap on) and the vent cover behind it (one screw). This allows access to remove the vent on the fridge side. Squeeze the tabs on the vent(freezer side) that lock the vent in place and push it through to the fridge side. Now disconnect all wire connectors between the control box and the fridge. They have locking tabs that have to be pried out to release. Remove the two screws holding the thermostat to the control box, and one at a time transfer the wires from the old stat to the new one and mount the new one in place. Snap the old thermostat sensor lead out of the vent assembly, straighten it out and pull the plastic tube off. Put a lubricant on the new stat lead to ease in inserting it into the tube. Do not kink the lead. Re assemble in reverse order, plug up the fridge.
21 of 22 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Allan from Allen, TX
Parts Used:
WP2198202
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
refrigerator would not stay cold
The wife found if we tapped the knob for the cold control the appliance would turn on. Upon further inspection I found what looked to be carbon particles under the part. I found the part easily with partselect.com, ordered it, installed it and its like we have a new appliance.
21 of 26 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Curtis from Pikeville, KY
Parts Used:
WPW10225581
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Pliers, Screw drivers, Socket set, Wrench set
Refrigeator would not drfrost...
I just removed a few screews and took the cover out of the ice box. Put my voltage meter to the refrigeator and realized the the unit was not defrosting...I then got the part number and entered it in on your web site. A few days later my part arrived. I put the part on and in just about 20 minutes I was up an running again...Thank you Part Select for fast and great service. I own 35 rental properties and having a online appliance parts store really saves me a lot of time and money.

Thank you
Curtis Hall
27 of 44 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Greg from Cary, NC
Parts Used:
W10190935
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
ice would not fall from ice maker
I ran all the ice maker module tests that I could find online, I tried cleaning the contacts inside the ice maker control module, nothing worked...so I finally decided to purchase a new control module. I had already had the module out and taken apart a few times, so the new one was very easy to install. Just removed the entire icemaker from the fridge, removed a few screws, took off the old module, put on the new one, replaced the screws, re-installed the icemaker in the fridge (it just slides in and out similar to a shelf). And 30 minutes later I heard the first batch of ice cubes drop! And by morning the bucket was nearly full. After two weeks of no ice and trying to fix it myself - the family was glad to have ice again (it was July in NC!). In retrospect, I should have followed the advice I found online and ordered the new part sooner and saved all of those frustrating hours of trying to "fix" the part myself.
22 of 30 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Christopher from Redmond, WA
Parts Used:
W10822278, WP2198202
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
greezer started to thaw and would not refreeze
tested thermostat and defrost time but both tested as working...called a repairman who came in and said they were both working...got annnoyed for not trusting myself. Repairman did say that he had seen defrost timers simply slow down, allwoing them to tesat as good but not actually working correctly. I ordered both the thermostat and the timer to cover all bases...actual replacement was simple.
21 of 27 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Walter from Cairo, GA
Parts Used:
4389144, WP2176759
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Refrigerator/Freezer not cooling
Disconnect power to refrigerator. Removed all food from Freezer. Removed all Shelves and shelf clips. Used phillips screwdriver and removed 6 screws from lower rear panel covering evaporator coil. Removed panel. Pulled plastic fan blade off top of motor shaft. Unclip top front of black motor retainer clip which then allowed the rear clip to unhook. Removed clip. Then removed 3 wires from fan motor, noting proper location for replacement. Slide the fan motor out to the left. Installed new motor. Reinstalled clip, hooking rear side first. Then rehooked the 3 wires. Slide fan blade back on top until secure. Tested everything at this point before reassembling rear panel. Then replace rear panel, replace the 6 screws, replace shelf clips and shelves and replace food. Very easy to do and saved about $150 over a service call to troubleshoot and re-visit to install after getting part
21 of 27 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Thomas from Flower Mound, TX
Parts Used:
4317943
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Over flowing Icemaker
Ice Maker would seem like it was the valve was leaking and Ice would build up at the rear of tray.
After listening to it cycle, (drop ice and fill) valve would open up again about 20 minutes later.
Over flowed and iceberg would form at rear.
Replaced icemaker unit and works fine now.
21 of 28 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
William from Springville, AL
Parts Used:
WP2315576
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Wrench (Adjustable)
Ice maker would not fill with water
Turn off the water supply.
Remove the two screws with a nut driver.
Disconnect the electrical connector.
Disconnect the water supply lines from the old valve.
Reconnect the water supply lines to the new valve.
(be sure to push the water line into the quick connect securely)
Reconnect the electrical connector.
Re-install the valve with the two screws.
Turn water supply on.
20 of 25 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Russell E from Rome, PA
Parts Used:
WP2315576
Difficulty Level:
Really Easy
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Pliers
Water was overflowing into ice bin.
First I ascertained that valve was faulty. Ordered replacement and installed without issue. Water now overflowed only during fill and found that filler neck had ice in it as a result of initial leakage. Defrosted with a hair dryer, removed ice plug and it now works as advertised.
22 of 31 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
SAL from UPLAND, CA
Parts Used:
4387535
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Screw drivers
Refrigerator stop working
First I removed the relay and over load and exam. Saw that the relay was burnt. Before I order the part I check to see if the compressor was still working by jumping the common start and run terminals.It did. I also checked the start capacitor with a capacitor tester it was good. I than order the part which came the very next day.Installed the part
22 of 32 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
jesse from hacienda heights, CA
Parts Used:
W10823511
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers
Water began to leak under the refrigerator. Source looked like it was coming from control valve suppling water to ice maker and water dispenser.
Followed instructions supplied. It was relatively easy and the parts fit exactly right. Sears wanted twice as much for the part and service would have charged me another $100 to come to my home. I saved over $100 doing the project myself.
21 of 31 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jerrel from REDDING, CA
Parts Used:
WPW10614158
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Socket set, Wrench (Adjustable)
Cracked Evaporation tray was leaking water on kitchen floor
I emptied refrigerator contents and tilted the refrigerator to the right so as to access the metal panel upon which the evaporation tray was resting. The metal panel is on the left side underneath the refrigerator and the evaporation tray is resting on the panel. I removed 4 screws that were holding the metal panel, pressed down on the panel, slid out the old, cracked plastic evaporation tray, inserted the new plastic evaporation tray, raised the metal panel to its original position, replaced the 4 screws, being careful not to pinched the water line that feeds the ice-maker. VOILA! Un-tilt the frig and re-stock it. It took a day for the temperature to stabilize, due to tilting, I think. New tray $45.
20 of 28 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
brett from garland, TX
Parts Used:
WP2198202
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
freezer intermitently warmed to around 31 degrees
Being a jet mechanic I had to familiarize myself with refrigerators, then after 2 or 4 hours of online studying, opened the door pulled the temp knobs of, removed the panel by gently prying the top of the panel out,then up and out with it. I found tapping on the thermostat shaft or wiring connection started the compressor, verifying my belief it was the thermostat. Don't mess with wiring if you don't know exactly what you are doing and unit is plugged in, you will electrocute yourself!!! I received the thermostat, UNPLUGGED THE UNIT from the house wall outlet, took one screw out of the upper inner wall at the very top to remove cover, one screw at the back top to remove the other cover (at the control vent) for access to remove sensor, then removed 4 screws , 2 front, 2 underneath to drop the housing for defrost timer, etc., and then took 2 screws from thermostat, unplugged wiring from thermostat (3 wires, be sure to put them back on the same place in the new thermostat). Remove old thermostat, slide plastic cover off sensor and slide back onto new thermostat sensor. Be careful not to kink the line or bend it to sharp you will damage it, (use gentle curves when bending it,) and re assemble everything in reverse order. This took about me 15 or 20 minutes start to finish. Plug into wall and watch thermometer to verify success.
16 of 17 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Richard from Newburgh, IN
Parts Used:
4317943
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
paint on bottom of ice maker was flaking into ice
1. shutoff water
2. removed 3 screws holding old ice maker. A small nut or screw driver is needed to get into a somewhat tight area
3. detached electrical connector
4. cut indicated area for water inlet to lie in
4. attached new electrical connector (no splicing needed)
5. attached new ice maker with 3 screws
6. put on water
17 of 21 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Tim from Leander, TX
Parts Used:
4317943
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
Slow to produce ice & tray damage
Removed the top two screws and one on the bottom which attach the ice maker to the side of the freezer. I unclipped the wire bundle from the side of the ice maker and unplugged the connector, totally removing the unit . The maker came with several different wiring setups, but I just used the existing. The contol arm on the new unit basically snaps into place and the above process is reversed to install the new unit. My old ice maker had an accelerator which blows cold air to the bottom of the tray to speed up ice production. This component was undamaged and by taking off the new units outer end cap and borrowing the clips from the old unit, this component can be installed on the new ice maker.
16 of 19 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the 10657022790
61 - 75 of 1127