- Customer:
- Emi from Arlington, VA
- Parts Used:
- W11395888
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
no water when under sink water filter installed
I called the installer of my filter unit and he told me that often, thhe fridge filter is the problem. Like magic it worked
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jorge from Miami, FL
- Parts Used:
- WPW10662129
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
The Freezer defrosted and everything on the top and the bottom spoiled
i had used your web site before and i read several problems that your readers had. i went to the back of the unit, removed the bottom cover and right there the i found the run capacitor and i chaged it. since i had only ordered this part to save money i went back and ordered the Start Device which when i took it off it was completely burned. the replacement part came labeled with 2 different compressor #, so i picked the one that i had and unpluged each wire. the part may differ from the one that it's in the unit but it worked when i pluged everything back on. it also helps to take a picture of everything before removing the wires in case you have to leave it and come back later. i hope to use this refrigerator another 10 years. thank you all for your help.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mark from ALTO, MI
- Parts Used:
- W10619951
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
leaking water onto floor
replaced the poorly designed "duck bill" drain with this P trap. Very simple repair done by accessing through the back of the refrigerator. The video on this website walked me right through the repair. It did however fail to mention that the ice has to be removed from the inside. I had to remove the drawer face and pull outs. Then the ice maker and back panel are removed. I used a heat gun and screwdriver to chip and melt the ice build up. If one had the luxury of having another refrigerator to move food in to you could just unplug the unit until the ice melts.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Roper from PALM BAY, FL
- Parts Used:
- WPW10662129, WPW10197428
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Stopped cooling/freezing
It is as easy as is shown in the self-help video. (1) Disconnect the power, (2) Roll the appliance out so you can get to the back, (3) Using a nut driver remove all the screws from the lower back panel then remove the panel, (4) Remove the tensioner wire, (5) unplug the electrical connection to the capacitor, (6) gently but firmly remove the capacitor and starter relay as one unit, (7) preassemble your new capacitor and starter relay as one unit, (8) now simply reverse your steps for installing and you are done! These two parts saved me the cost of a new refrigerator. Almost as easy as changing a light bulb. PS: while you have the panel removed you can do a thorough cleaning with a soft brush and vacuum.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mary Sue from Tinley Park, IL
- Parts Used:
- WPW10235370
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Glides easy to install, about 15 minutes
you need to take the deli drawer out, make sure your flat head screw driver is large enough for the head of the screw as screwing into the plastic is a bit difficult. Other than that there are 2 screws and its pretty easy.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Daniel from RICHTON, MS
- Parts Used:
- W11613295
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Pliers
Refrigerator would cool for a very short period of time. Then the compressor would shutdown via internal thermal overload or high head pressure. This was caused by the lack of airflow across the condenser coils and compressor.
(1) Slide out appliance and remove power source. (2) Removed lower access cover on rear of refrigerator. (3) Disconnected plug to the condenser fan motor. (4) remove blades by pulling gently forward (5) remove mounting hardware holding the fan motor (3 screws) (6) motor is now free and new motor can be installed
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- T.W. from GREENWEL SPGS, LA
- Parts Used:
- W10827914
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
Door To Deli Fresh Broke In Half
Snap Out
Snap In
Yes That Easy!!
Snap In
Yes That Easy!!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Gloria from Laurinburg, NC
- Parts Used:
- WP67006331
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Broken latch on water filter cover.
Reviewed replacement instructions video on your website. Just followed the easy instructions to pop out old cover and pop in new cover. I would not have tried to replace it myself had I not seen your video. Super easy.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Peter from MASSAPEQUA PK, NY
- Parts Used:
- WPW10662129, WPW10197428
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Pliers
Warm ref and frz
Removed old starter and capacitor as per your website instruction.
Plugged in new parts.
Compresser turned on
Plugged in new parts.
Compresser turned on
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jeffery from RUSTON, LA
- Parts Used:
- W10502642
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers, Wrench set
Had to replace the water reservoir on my refrigerator
The replacement part provided was not an exact replacement. The part did not include a water reservoir. Instead, it had a 25 ft long water line that ran from the water filter to the water connection behind the fridge. The long water line was difficult to deal with, did not fit easily into the space provided for the water reservoir, and is coiled up behind my fridge. The part did work, but I'm unhappy with not having the resevoir.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Tim from WINTER PARK, FL
- Parts Used:
- W11197396
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Socket set
Helpful to have instructions
Since there were no instructions, I was a tad hesitant but dove in. I was just replacing the right end cap, not the left. Removed the involved shelf as well as the two drawers above. Undid the three screws involved and carefully removed the slide rail end cap as well as a part in the back that was attached. That was the hairy part. It took a bit of time to remove it since everything seems so brittle but I was careful and got the assembly out without breaking anything. Also had to remove the slide rail and humidity control. Nothing to removing and replacing the slide rail. You just have to put it back correctly oriented. This was easy. I just looked at the one on the left, which I hadn't removed. Most time consuming part was cleaning things that were normally inaccessible, before re-installing.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Linda from LOVINGTON, NM
- Parts Used:
- W10827914
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Deli Lid Tray broke and was unable to glue back.
Ordered the part. When came in I took it out of the box and slid the two end posts into the provided holes. Lid fixed in less than 5 minutes. Part came in on the third day because I ordered on Friday afternoon.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Rana from Pittsburg, KS
- Parts Used:
- WPW10534162
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
The toe grille broke when we 1st put it on
We snapped the new one on correctly this time.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Cuong from Camarillo, CA
- Parts Used:
- 8201515
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Screw drivers
Ice maker just stpooed making ice
The troubleshooting time takes about 20 to 30 minutes. After checking out the solenoid (valve water), the water line, and the electronic board (emitter/receiver) are working fine. The only thing left is the ice module. I called Partselect and talked to a sale rep to make sure I get the right part, and the lady was so helpful by sendind the picture of the part so I can review before ordering it. I received the part in 3 days ( normal shipping) and did the folowings:
1) Unplugged the power cord from refrigerator.
2) Removed the ice module by removed a 1/4" screw from under the right side of the icemaker that retains the icemaker and a “U” plastic clamp and then pull out the whole unit it from the track.
3) Unplugged the cable connected to the ice maker.
4) Using the phillips screw driver to remove the 3 screws. Carefully pulled out the ice module and installed the new ice module.
5) Put the ice maker back to the freezer, plug the cable back to the ice maker and put the clamp and tighten the nut.
6) Plugged the power cable back to the wall.
The first ice I got in an hour and a full bucket of ice in less than 24 hours. I spent less than $80 for the whole thing. Thank you so much Partselect for the great service and the stories posted, it really helped me to get it done.
1) Unplugged the power cord from refrigerator.
2) Removed the ice module by removed a 1/4" screw from under the right side of the icemaker that retains the icemaker and a “U” plastic clamp and then pull out the whole unit it from the track.
3) Unplugged the cable connected to the ice maker.
4) Using the phillips screw driver to remove the 3 screws. Carefully pulled out the ice module and installed the new ice module.
5) Put the ice maker back to the freezer, plug the cable back to the ice maker and put the clamp and tighten the nut.
6) Plugged the power cable back to the wall.
The first ice I got in an hour and a full bucket of ice in less than 24 hours. I spent less than $80 for the whole thing. Thank you so much Partselect for the great service and the stories posted, it really helped me to get it done.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Geraldine from MUNDELEIN, IL
- Parts Used:
- W11395888
- Difficulty Level:
- Very Easy
- Total Repair Time:
- 15 - 30 mins
Did not need filter
Unscrew filter. Screw on filter bypass
Was this instruction helpful to you?
Thank you for voting!