36348047897 Kenmore Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Allen from Schenectady, NY
- Parts Used:
- WR51X10101
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
No Defrost - Top of freezer thawing
By the time this failure (failed defroster heating element) is evident (top of freezer starts thawing), the entire freezer coil is encased in a block of ice & frost is visble on the back freezer panel.
Empty the freezer & unplug (or turn circuit breaker off) then remove all racks and the light bulb then remove the two lower drawer guides using a phillips srewdriver (2 scrwes each). Use a 1/4" nutdriver to remove the two panel screws on either side of the light bulb socket and pull the panel out, unclip the green grounging wire and set panel aside. this exposes the freezer evaporator coil which is probably encased in ice. If so, use a heat gun or hair dryer to melt the ice away. This takes a half hour of heat application and a bowl or other catchpan should be placed under the coil to remove some of the resulting melting runoff so the evap. pan under the fridg/freezer unit won't be overwhelmed with the excess water.
Replacing the defrost heater & bracket assembly itself is just a matter of removing two phillips screws on either side of the bracket assembly, pulling the bracket free and then uncliping the two electrical terminals. Clip in the new unit to the eletrical terminals & replace the screws, reinstall the rear panel (don't forget to reconnect the ground wire), install the drawer backets, light bulb, shelves and drawer & reapply power. Replacing the bracket itself w/o the defrost proceedure takes about 15 minutes.
Note: If this symptom occurs and is diagnosed (the heater tube will be black and electrically read as "open" using an ohmmeter) and you cannot get the heater assembly & bracket assembly immediately, you can use the heat gun (hairdryer) manual defrost proceedure noted above to get the the unit running while you await the parts arrival. I used the manual defrost procedure and there was just some moderate frost on the coils after five days when I was able to install the replacement part.
Empty the freezer & unplug (or turn circuit breaker off) then remove all racks and the light bulb then remove the two lower drawer guides using a phillips srewdriver (2 scrwes each). Use a 1/4" nutdriver to remove the two panel screws on either side of the light bulb socket and pull the panel out, unclip the green grounging wire and set panel aside. this exposes the freezer evaporator coil which is probably encased in ice. If so, use a heat gun or hair dryer to melt the ice away. This takes a half hour of heat application and a bowl or other catchpan should be placed under the coil to remove some of the resulting melting runoff so the evap. pan under the fridg/freezer unit won't be overwhelmed with the excess water.
Replacing the defrost heater & bracket assembly itself is just a matter of removing two phillips screws on either side of the bracket assembly, pulling the bracket free and then uncliping the two electrical terminals. Clip in the new unit to the eletrical terminals & replace the screws, reinstall the rear panel (don't forget to reconnect the ground wire), install the drawer backets, light bulb, shelves and drawer & reapply power. Replacing the bracket itself w/o the defrost proceedure takes about 15 minutes.
Note: If this symptom occurs and is diagnosed (the heater tube will be black and electrically read as "open" using an ohmmeter) and you cannot get the heater assembly & bracket assembly immediately, you can use the heat gun (hairdryer) manual defrost proceedure noted above to get the the unit running while you await the parts arrival. I used the manual defrost procedure and there was just some moderate frost on the coils after five days when I was able to install the replacement part.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Charles from Barnwell, SC
- Parts Used:
- WR9X489
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
Refrig & Freezer Warmer than normal but could manually reset and defrost. Then good for several days.
Removed guard at bottomof frig. Located timer & performed tests. Manually rotated timer motor until defrost cycle start. Watched timer for several hours. Timer did not come out of defrost.. Rotated timer more until compressor started. Cooled fine several days then started to get warm again. Manually defrosted and started compressor again. Ordered part. Followed wiring diagram on timer for push on lugs. Frig now back to normal operation.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Christopher from Sarasota, FL
- Parts Used:
- WR51X10101
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Screw drivers, Socket set
Open defrost heater
The most difficult part of the repair was the melting of the ice and preparation. I did change a single element heater for a dual element heater, which required a little manual flexing of the sub-frame, but it assembled with little issue. I was lucky, I did not have to splice the extended harness connection. Rerouting my existing gave sufficent length.
Not sure if the single elements were changed for dual, but it did have the same PN as the unit I replaced.
Not sure if the single elements were changed for dual, but it did have the same PN as the unit I replaced.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Charles from Longs, SC
- Parts Used:
- WR51X10101
- Difficulty Level:
- Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Screw drivers
Freezer building up Ice
This is such an easy fix!
1-Unplugging the fridge and emptyi it. Remove all shelves.
2-remove the 2 screws at the top of the back panel with a 1/4 inch nutdriver. You'll have to tilt ithis panel forward and sideways to get it out.
3- DO NOT CHIP AT THR ICE COVERING THE COOLING COILS? Replace one shelf and rest a hair dryer on low heat on the shelf.. Plug the drain hole at the bottom with a rag so all the melted ice water doesn't flood the floor under the fridge. Soak up the water with a rag and bucket- this should take 20-30 minutes.
4-Remove the red and blue power cables from the element. Only 2 philips head screws hold the defrosting element in place. Once it's out you can tell it's burned out because it looks black like a burned out lightbulb.
4-Plug in the red and blue power cables to the new unit. You will need to reroute the blue power cable because the new unit has both power connections on the same end.
5-Replace the cover panel by sliding it in at an angle and replace the 1/4 inch screws.
6-Replace the shelves and plug in the fridge.
That's it!
1-Unplugging the fridge and emptyi it. Remove all shelves.
2-remove the 2 screws at the top of the back panel with a 1/4 inch nutdriver. You'll have to tilt ithis panel forward and sideways to get it out.
3- DO NOT CHIP AT THR ICE COVERING THE COOLING COILS? Replace one shelf and rest a hair dryer on low heat on the shelf.. Plug the drain hole at the bottom with a rag so all the melted ice water doesn't flood the floor under the fridge. Soak up the water with a rag and bucket- this should take 20-30 minutes.
4-Remove the red and blue power cables from the element. Only 2 philips head screws hold the defrosting element in place. Once it's out you can tell it's burned out because it looks black like a burned out lightbulb.
4-Plug in the red and blue power cables to the new unit. You will need to reroute the blue power cable because the new unit has both power connections on the same end.
5-Replace the cover panel by sliding it in at an angle and replace the 1/4 inch screws.
6-Replace the shelves and plug in the fridge.
That's it!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- danny from colorado springs, CO
- Parts Used:
- WR51X10101
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
freezer anf refrigerator got warm on both sides. Seemed like there was no air flow.
Parts select sugested checking the freezer side on the side by side if there was frost on the back panel. I took the back panel off on the freezer side inside the freezer. I found that the freezer coils were full of ice.Had to use a hair dryer to melt all the ice. The heater element was bad on the bottom of the freezer. I ordered a new defrost element an installed in 40 minutes and is running fine.You can still use the refrigerator until the new part comes in if you melt off the coils.It will last about 2 weeks.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from Lockport, IL
- Parts Used:
- WR13X10020
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Socket set
Old hinge washer worn out.
First I placed a 2x4 under the frig door to keep it in place while I removed the hinge on the bottom of the door. I removed two screws holding the hinge and one screw holding the washer in place. I also loosened a screw adjacent to the washer so that I could more easily remove and replace the washer. The parts went in easily. The repair took much less time than I anticipated.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Chris from Kingman, AZ
- Parts Used:
- WR51X10101
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
Refrigerator and freezer not getting cold enough.
First I removed the two screws that hold the element in place. I then pulled the element out about 3 inches and disconnected the two wires..
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Paula from GREENEVILLE, TN
- Parts Used:
- WR51X10101
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
Fridge not cooling, freezer icing up
This fridge had this same problem 4 other times, each time about 1 yr apart. Being as I considered myself ''mechanically challenged'' my wife always contacted her favorite appliance repair man. However, he was unavailable, so wife was gearing up to go ahead, bite the bullet, and buy a new fridge. We really didn't want another bill to worry with so she suggested I try the repair myself. She'd watched the repairman do it the last couple of times and ensured me it would be ''a piece of cake'' plus save us some bucks and put off an added expense at least a little longer. Ordering the part from this site was simple. The fridge did have the old 1 bulb element and the new one was the 2 bulb element so I was afraid I'd have to do some splicing, but lucked out and the wire was easily redirected and reached without any stress or problems to plug into the new part. She watched the install video and was able to talk me through it without any problems. We saved at least $125 install bill, plus put off making a big item purchase a while longer. I hope the new 2 element defroster does a better job and we might just get 10 more years out of 'old faithful'!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from PARKVILLE, MO
- Parts Used:
- WR02X10098
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Socket set
Had a 'ticking' sound
Separately (from a different site) purchased new compressor fan and motor. I purchased the grommets here because the other site listed the grommets as temporarily out of stock. I did watch one of the videos on PartSelect about the grommet replacement. Repair was pretty simple, biggest challenge was getting to the screw on the far side of the motor. Removed the two screws holding the fan motor into place. Removed motor and blade. Reinstalled with new fan blade, new grommet and new motor.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Charles from HERNANDO, FL
- Parts Used:
- WR51X10101
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
Frost vuildup back panel of freezer, freezer too warm
Followed the video describing the repain and the written directions. The Video is excellent and made the job easy to follow
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ron from BAKERSFIELD, CA
- Parts Used:
- WR60X10030
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Old fan had broken blade, needed to be replaced
Unplugged the refrigerator then used the cordless drill to remove the 6 screws on the access panel on the back of the fridge to be able to get to the fan. Was able to pull the fan off by hand and push the new fan on by hand. Plugged the refrigerator by in and watched the fan run for a few minutes then replaced the access panel. Really quick and easy repair.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from Medford, OR
- Parts Used:
- WR13X10020
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Socket set
Emptied refrigerator door shelves. Supported door with 4x4 blocks.removed old door hinge and replaced with new.
Emptied refrigerator door shelves. Supported door with 4x4 blocks. Removed old door hinge and replaced with new door hinge and cams. Pleased with end result and dealing with PartSelect.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- frank from Pittston, PA
- Parts Used:
- WR51X10101
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Appeared to be too large at first...
At first the part appeared to be too large because of the change from one heater to two heaters in the replacement part. It was necessary to push a copper refrigerant line back out ot the way about an inch or so before the part would fit properly. This might take a little courage from the do-it-yourselfer, but it moved easily and seems no worse for the move. Currently the fridge is working well(two weeks) with no buildup of any frost on freezer panel as previouly noted. Overall experience was just fine. Makes d-i-y guy look good!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Sharon from Deerfield Beach, FL
- Parts Used:
- WR51X10101
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Coils at back of freezer icing over
After reading posts on this website, I determined I needed to replace the defrost heater. Removed heater to take a closer look and after testing with a voltmeter determined it needed replacing. Ordered part online and could not believe how quickly it arrived. Blue wire that travels down the left side of the freezer coils had some damage on the end of the plastic connector so was pleased to find that I was able to splice the extension wire provided in the defrost heater kit onto the blue wire and dispose of the damaged end. It's been about 10 days and I do believe my problem has been solved!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- charles from leicester, NY
- Parts Used:
- WR51X10101
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
the top of freezer was warm and also refrigerator
I removed food, then removed shelves.
The light bulb and shade had to be taken out.
removed two screws from interior back panel.
defrosted cooling coils
removed two screws from defrost heater
took off two wires ...done
reversed procedure to finish installation
The light bulb and shade had to be taken out.
removed two screws from interior back panel.
defrosted cooling coils
removed two screws from defrost heater
took off two wires ...done
reversed procedure to finish installation
Was this instruction helpful to you?
Thank you for voting!