Customer:
Neptali from Groton, MA
Parts Used:
5303918549
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Wrench set
Freezer is working but not the refrigerator.
Removed the cover inside the freezer. Found out that the motor/fan was not working. Ordered through PartSelect. Got the parts in 3 days. Installed it for less than 30 minutes. Very easy. It saved me hundreds of dollars. We considered buying a new fridge but not anymore. , it only cost me $70 including shipment charges. (Make sure you unplug the appliance first before opening the cover. Remember safety first.)
17 of 19 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Denise from Lowell, MI
Parts Used:
5304464438
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
just quit working
Bought a new
capacitor.
18 of 24 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from Roanoke, VA
Parts Used:
5303918774
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Socket set
Replaced the heater-core motor
It was fairly easy. Only had to remove the back cardboard. Remove 3 screws and the power plug.
Replacing the screws took a little time the motor mount didn't seem to be tapped exactly for the screws supplied and it was in a tight area. Its working great now.
17 of 22 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Vicki from Johnson City, TX
Parts Used:
5304464438
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Refrigerator was not cooling
This was a simple job. Raised the flap in the back that houses the compressor, removed the wire that holds the relay, pulled out the old relay and pushed the new one on. Replaced wire holder and that was it. Plugged it frig and freezer is at zero and lower compartment at 35. As easy as brushing your teeth!
16 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Amber from SHERMANS DALE, PA
Parts Used:
5303918774
Difficulty Level:
Very Difficult
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Pliers, Socket set
Fan motor no longer functioning and needed to be replaced
The most difficult part was the removal of the existing fan and shroud. There is very little room to work between the condenser and the coils where the fan is located. The old shroud had to be removed as it was not compatible with the mounting for the new fan motor and blade. Make sure to unplug the refrigerator and give the coils some time to cool down. The first step was to remove the old fan blade... it simply pulls off. Next you need to remove the two bolts holding the fan shroud to the floor of the refrigerator. Then you need to remove the old fan motor from the shroud... unplug the wire connection and remove two small bolts that hold it on. I was lucky to have a VERY small ratchet to get into these tight spaces. Now is the really hard part, removing the metal fan shroud takes a lot of twisting and turning to get it out. The coils have a little play in them, but you must be very careful of the tubing and connections. Also, the coils are very sharp. Once this is out, IF you can get it out....I had my doubts along the way, you can start to put the new parts in... beginning with the new fan shroud which fortunately is made of plastic and has some give which makes it easier to get in. Then you can mount the new motor to the shroud with the three new screws. Plug in the wire connection, add the foam tape to the shroud and mount the shroud to the floor of the frig with the original two bolts. Lastly, attach the fan blade. This replacement kit is well constructed, fits perfectly and contained all the necessary parts (fan motor with wiring connection, mounting screws, wire connection adapter, fan shroud, foam tape and fan blade), but no detailed instructions come with it. I was lucky to get the old fan shroud out without doing any damage to the surrounding parts, but this part was very difficult for a do it yourself person. I would be interested to know if a professional has some other tips for this part of the replacement process.
12 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Frederic from Daytona Beach, FL
Parts Used:
5304464438
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Refrigerator quit running
I located the part that was the culprit as it had buzzed very much before quitting. This is an easy removal as the part is in a two prong jack and just needs to be carefully removed with the new part inserted back in the jack provided. The refrigerator works fine now, but the run capacitor will still buzz on start up of the compressor. I do hope this is normal in this model? anyway it runs fine mow. Thank you.
22 of 42 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
MICHAEL from BAYTOWN, TX
Parts Used:
241872502
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Door gasket was cracked and falling apart
Watched your video, used a stiff putty knife to pry the gasket loose.Cleaned the surrounding area and pushed the new gasket in. I used a plastic body moulding tool to make sure the gasket was sealed. Very easy repair!
11 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mary from Kenmore, WA
Parts Used:
5303918549
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
Food compartment not cooling, freezer working well.
Fantastic!
Sent in a brief description of problem and model number. Reply and description of other customers experiences guided us to the exact problem.
We ordered the part on Friday and it was here on Tuesday.
I prepared the freezer compartment for the removal of the old motor and on Sunday husband installed new Evaporator Fan Motor.

It works and is cooling like it did when it was new.

This has been a great experience as all repairmen wanted at least 60.00 to just come out and determine what the problem was. I can only imagine what the final bill would have been.

This was easy and inexpensive.

Thanks for all the help.
13 of 19 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Amy from PITTSBURGH, PA
Parts Used:
5304464438
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Freezer and refrigerator stopped cooling
The site offers a video for this part which worked perfectly. In addition to replacing the part, since the cardboard panel was off, we also cleaned all the dust off of the coils which someone recommended to do annually.
8 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
George from Worcester, MA
Parts Used:
240331502
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Door shelf bar broke
This was a really simple repair. The hardest part was getting the broken piece of the plastic end cap out of the metal retainer bar. I had to use a small screwdriver to gently pry it out of the two notches in the retainer bar. Then I just slipped on the new part, and snapped the whole retainer bar into the fridge door and that was it.

If the end cap doesn't lock into place when you slide it into the metal retainer bar, you may need to bend the bar (gently) to get the notches around the plastic clips. You don't need a lot of force to do this since all you want is to lock the end cap in place.
8 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
charles from parker, CO
Parts Used:
5303918549
Difficulty Level:
A Bit Difficult
Total Repair Time:
More than 2 hours
Tools:
Nutdriver, Screw drivers, Socket set
Lightning struct the house and fried the evap thermostat
Noticed the evap fan wasn't working, so trying to disconnect the wire broke the connection so had to order a new motor. Installed the motor but it still didn't work. Had a technician look at it and he said it was the control board. Ordered and installed control board and still didn't work. The only element left is the evap thermostat. Jumped the thermostat and it worked so ordered and installed a thermostat. It works now
8 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Charles from Front Royal, VA
Parts Used:
240505801
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Screw drivers
Switch would not allow door to close.
Removed screws holding unit and removed unit. Removed switch from connectors in unit. Replaced unit without switch. On day switch arrived (delivery was prompt) my wife replaced switch by attaching the two connectors and slipping into unit without having to remove entire unit. How easy was that!!!
7 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Karine Lepold /BM CARGO from Miami, FL
Parts Used:
241872501
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Freezer door gasket with a holes
/
7 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Lise from CEDAR GROVE, NJ
Parts Used:
316538904
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Oven light bulb went dark; it needed replacing
Twisted replacement bulb into place easily. Let there be light!
9 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Denver from BLAIRSVILLE, GA
Parts Used:
5303918549
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
Evaporator fan motor quit and would not circulate cold air from coils.
Remove shelves and rear panels to get to motor. Motor is held in place on shroud by simple strap. Remove fan blade, then un hook strap, remove and save rubber spacers on old motor to reuse to remount new motor. New motor Mew motor has wiring harness that is universal. Cut out the three wires that go to the new motor leaving long as possible, cut wires from old motor as long as possible, strip ends of all wires 1/2 inch, connect wires by color,slip into provided wire connectors and crimp. Pull on wires to insure connection. Tie wires together so they don't touch the coils. Plug in and check operation. If all is working unplug and replace all covers and shelves. Plug back in and it will take few hours to reach operating temperature. Video of side by side repair shows easy removal of panels and motor.
6 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the 25331430101