- Customer:
- Bruce from Mobile, AL
- Parts Used:
- WR2X4550
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Drive cup broke due to ice cube jamming it
Remove three screws insert part; manually checked out drive and waited for ice to buildup and it worked like new.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jim from Jacksonville, FL
- Parts Used:
- WR17X2059
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
crushed ice feature inoperative, broken pieces in water dispensed.
Found broken pieces of deflector in delivered ice. Removed dispenser, carefully disassembled it, marking fasteners, sprimgs, and levers. Local repaimen say no replacement part available, must replace entire ice maker @ $350. Found exact part in your online reference, ordered at price of $3.76, part arrived two days later--perfect fit, exactly same as original. Reassembled, and it works exactly like new. Family very happy. Good job!!!!!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Robert from Orlando, FL
- Parts Used:
- WR55X129
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
ice being made but would not dispense
Easy repair. Snapped cover off control panel. Removed 4 phillips head screws on control board assembly. Removed (2) connectors from assembly and pulled out defective unit. Installed new control board in reverse order. Everything now working. Very fast and easy repair once you have the part.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- George from Brandywine, MD
- Parts Used:
- WR57X10051
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
no Ice
Turned off The water supply. Removed the back panel corner(nut driver). Removed valve (nut driver) and water supply inlet line. Cut the old outlet lines at the valve (new lines are push in) disconnected electrical lines, Reinstalled inlet line and electrical lines. Reinstalled valve and back panel. Turned on the water. Ice maker filled with water and a short time later I had ice. Easy job.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Charles from Keller, TX
- Parts Used:
- WR30X10093
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Ice Maker would not fill.
Was concerned that new icemaker was quite a bit different than the one we were replacing. Called GE to confirm it was correct.
Went ahead and installed the unit, using the supplied electric cable adapter.
A little difficult to deal with the extra cable, but everything worked OK and it's making ice normally.
Went ahead and installed the unit, using the supplied electric cable adapter.
A little difficult to deal with the extra cable, but everything worked OK and it's making ice normally.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from Randle, WA
- Parts Used:
- WR32X1492
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
The vegetable pan was broken from closing the door on it too hard when still open
I just slide the new one in place, using exsisting sliders. I had to remove the old grab handle from old pan and snap it into place on new pan.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Barbara from Medical Lake, WA
- Parts Used:
- WR17X4312
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Ice maker would not dispense ice cubes
Removed the face plate (4 screws) on the ice bucket/auger and put it on the new unit.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Henry from Rockville, MD
- Parts Used:
- WR17X4312
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
I had a smell from the ice and bad taste
I removed the 4 screws from the cover and replaced the auger and ice bucket assembly. Extremely simple and I was amazed how easy it was.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Cathy from San Antonio, TX
- Parts Used:
- WR17X3489
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Broken light shield in freezer
SUPER easy repair, taking about 5 minutes. After taking out the ice bin, I removed one small phillip's head screw, put the light shield in place, and tightened the screw.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Charles from Rose Bud, AR
- Parts Used:
- WR50X122
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Wrench set
Refrigerat
rerfrigator side not cooling After determinating that the defrost timer was running I turned it to defrost and watched tosee if frost started to melt. When it didn't I checked the heater with ohmeter, checked OK, so the only other component in the defrost system is the thermostat. Then just a matter of cutting and splicing wires and snapping the new thermost in place
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Scot from Fort Collins, CO
- Parts Used:
- WR17X4358
- Difficulty Level:
- Difficult
- Total Repair Time:
- More than 2 hours
- Tools:
- Nutdriver, Screw drivers, Wrench set
Tubing from vavle to reservoir had been degraded by compressor heat and had cracked, leaking water when door water dispenser was used.
- Disconnect the valve assembly and remove electrical connection to water dispenser valve to prevent accidental water discharge
- Disconnect tubing from valve assembly, remove and keep compression nut.
-Disconnect tubing from junction to door tube remove and keep compression nut
-Remove screws used to mount reservoir, pull tubing into main refrigerator compartment and remove old reservoir and tubing.
- Note that one of the tubes on the new reservoir is 2' too short.
- Go to hardware store to purchase 5/16" universal tubing compression junction.
- Install reservoir and feed tubing through holes in main refrigerator compartment.
- Route tubing through woven tubing protectors and clips.
- Trim tubing to length and install in valve using old compression nut.
- Splice the piece of tubing trimmed from supply side of reservoir to the outlet side tube using the fitting purchased from the hardware store.
- Connect end of tubing to existing junction using old compression nut.
- Re-connect wires to valve solonoid and test for leaks.
- Re-install valve assembly to refrigerator frame.
- Disconnect tubing from valve assembly, remove and keep compression nut.
-Disconnect tubing from junction to door tube remove and keep compression nut
-Remove screws used to mount reservoir, pull tubing into main refrigerator compartment and remove old reservoir and tubing.
- Note that one of the tubes on the new reservoir is 2' too short.
- Go to hardware store to purchase 5/16" universal tubing compression junction.
- Install reservoir and feed tubing through holes in main refrigerator compartment.
- Route tubing through woven tubing protectors and clips.
- Trim tubing to length and install in valve using old compression nut.
- Splice the piece of tubing trimmed from supply side of reservoir to the outlet side tube using the fitting purchased from the hardware store.
- Connect end of tubing to existing junction using old compression nut.
- Re-connect wires to valve solonoid and test for leaks.
- Re-install valve assembly to refrigerator frame.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Dean from Folsom, CA
- Parts Used:
- WR30X10093
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
The Icemaker failed to make ice
I pulled the refrigerator away from the wall and turned off the water to the refrigerator and unplugged it from the wall. After removing the icebucket from the freezer I located the mounting screws, loosened them, unplugged the electrical connection below the icemaker and carefully removed it from the freezer. I unpacked the replacement icemaker, matched it against the original and attached the electrical connection adapter. Using the slots provided on the new icemaker I placed it over the mounting screws after aligning the water inlet pipe properly. I tightened the mounting screws while maintaining the icemaker in a level position. I plugged in the electrical connector. Then I replaced the icebucket, plugged in the refigerator back into the 110VAC outlet, turned on the water and repositioned the refrigerator in it's normal position.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Alan from Jonestown, TX
- Parts Used:
- WR55X129
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Screw drivers
Water / Crushed Ice / Cubed Ice Switch Broken
Unplugged and shut off water. Popped off the face plate from below. Unscrewed 4 screws. Pulled out control board assembly. Pulled off two wire connectors. Unscrewed 2 screws to remove control board fastener. Replaced control board and reversed steps to assemble. When plugged in fridge, the switch was stuck on, so unplugged. Had to remove the rubber push plate and reassemble making sure the plastic lever was set properly in the control board. Reassembled and it worked properly.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- robert from WOONSOCKET, RI
- Parts Used:
- WR51X10055
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
Freezer coils were iced up,was not cold enough,suspected the heater was the culprit
I had looked at videos on you tube,it looked simple enough. I mostly do my own repairs so I gave it a shot. the job went well,if you do not fix things around the house don't try to do the repair,find a handyman in your neighborhood to help you out,cheaper than calling a refrigeration man. It is not that hard to do.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- barry from HARTFORD CITY, IN
- Parts Used:
- WR51X10055, WR50X122
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
warm refrigerator, and freezer not defrostt
i replace the defrost thermostat and defrost heater and bracket assembly. i did not know what was wrong with the refrigerator until i found your web site. i would like to thank all the friends who explain this process. this save me the price of a service call. this was a very easy job