Jania from Novato, CA
Parts Used:
WR23X10725
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
The refrigirator light would not come on.
Poped out with screwdriver the old swithch and unplugged the two wires. Plugged in the wires to the new swithch and pushed it back in the hole where the old switch was before.
24 of 38 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Rene from Bronx, NY
Parts Used:
WR9X489
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Frig would stop working every so often. Lots of food got spoiled.
Got part overnight. Unscrewed cover plate at top of regerator compartment, disconnected old part, connected new part. Screwed back plate. Voila!

I saved a bunch of money!
17 of 19 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Tracy from Yuba City, CA
Parts Used:
WR29X160
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Stripper on the icemaker broke into pieces.
Remove the two nuts holding the top of the unit to the side of the freezer using a 1/4 in nutdriver. Pull the unit out and unplug it from the back of the freezer. Remove all pieces of the broken stripper. The replacement part fits onto a peg on the back of the icemaker and into a slot. Bend into place and slide into position.
18 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Christopher from Madison Heights, MI
Parts Used:
WR9X489
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Refrigerator to warm freezer ok
The comments from customers experiences gave me the confidence that the defrost timer was the problem since the compressor was still working and it went just as they all said, four 1/4' hex head screws and I had access to the old timer, unplugged the old ,plugged in the new and put the four screws back in. Nothing happened so after a while I looked a bit harder at the accessable part of the timer after intallation and saw what looked like a dial. I turned the dialclockwise and immediatly the compressor turned on. I have not found any information as to how much or little to turn this dial which obviously is an adjustable cycle setting so I just turned it all the way, so far everything is working alright.
16 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Heather from Pennington, NJ
Parts Used:
WR51X10101
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
loss of refrigeration
After mopping up the floor - the whole freezer that was iced up melted - that's how I found out about the problem...

Disconnected the power, emptied the freezer, removed the shelves. Under the ice maker was the light cover - I removed that first, then the two screws holding the back panel in place - The light panel was covering the top screw.

With the screws removed, I pulled out the back panel - which needs to be jiggled around a bit to get it past the shelf brackets.

With the cover off, I could see the mostly de-iced coil at the back of the unit. The defrost heater was visible at the bottom of the coil frame. To remove the bracket/heater, I removed the two cross head screws (one on each side) holding the bracket to the coil frame. I then twisted the side tabs of the bracket assembly and pulled the entire bracket/heater/wiring from the coil frame.

With better access tot he bracket/heater I was able to disconnect the wires. I grabbed the new bracket/heater, reattached the wires and pushed the bracket/heater back onto the coil frame and closed the side tabs firmly attaching the bracket to the frame. I then screwed the tabs back onto the frame.

Replaced the back panel, screwed it in place. Put back the light cover and then the shelves. Turned the appliance back on and left it for a few hours - before checking to see if there was any drop in temperature. There was, so after 24 hours or so I reloaded all the food...

NOTE: I was certain that the heater had failed! When I pulled the OLD one out it was obviously burned out - the glass tube was blackened and pieces of the element could be seen in the bottom of the tube.
15 of 17 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Terry from Simi Valley, CA
Parts Used:
WR23X10725
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers, Screw drivers
Switch failed on which kept the refrigerator warm due to heat generatered by light bulbs.
While the switch did last for 9 years, the design is poor due to the failure mode. The failure should be to fail off or not able to turn on the lights which would be inconvenient but would not warm the refrigerator contents. Arcing at the contacts eventually caused the switch to "weld" closed. It is not obvious that this is occurring so it took some time to recognize why the temp inside the ref was high while the freezer was OK. Replacing the switch was easy once it was recognized as the problem. All that was required to replace the switch was to remove the screws holding a fiber cover and then pulling off the aluminum cap which covered the switches. Unplug the switch an squeeze the keeper on the switch to release it and pull down. Pop the replacement switch in place and plug the wires harness back in. All in all it took much less time to replace than it has to write this up. T Pope
18 of 26 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David T from Irvine, CA
Parts Used:
WR57X10051
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers, Wrench (Adjustable)
Water Leak From The Ice Make - Water All Over The Frig
Replace the old water valve (wr57x11) with the new one (wr57x10051: make sure you unplug the 110 ac power . And close the water come to the refrig. First 1. Open the paper panel on the back with screw driver. 2 Use a small adj. Wrench to take the old valve of. 3. Label the connector and its terminals in a proper number to identify their connector. 4. Unscrew 2 water hoses - one to the drinking one to the ice maker. They are in diff. Sizes - make sure to mark where the hoses connected in case you need to use it again. 5. Cut of the thread section on the hose end - you do not need thread any more on the new water valve. 6. Make sure the new valve is in the same position as the old one. Then plug the water hoses to the valve - and connector terminals. There are 2 new terminal adapter in your new package. These new adapter will be fit to the old hardness for connecting to the new valve. 7. Secure the valve onto the refig frame then plug in the water hose to make sure no leak at the valve. The new valve has new type of self-lock plug ( not thread ) to the 2 water hoses. Make sure to press hard so the hoses are fit in to these new water . Valves. Turn on the water and power on on the refrig. That's all. Very simple save $300 for hiring the service man. Good luck to all.
14 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Tom from Bradenton, FL
Parts Used:
WR30X10154
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Ice bucket missing
I discovered the ice bucket missing from my rental unit at the beach. I was able to go online with my Blackberry, easily navigate your website using the model number to look up the part information , order it, and have it in place for the next renter.
Without access to a friendly user website, I would have faced considerable delay in getting this part.
14 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ralph from Portland, OR
Parts Used:
WR13X10020
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
Door hinge cam crumbled
Simple job, empty the door shelves, remove top hinge, lift door off bottom hinge, remove bottom hing. The reassembly is the reverse, with a little cleaning along the way and a little white lithium grease on the hinge pins and cams.
14 of 16 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Cristina from Los Angeles, CA
Parts Used:
WR30X10093
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
ice maker not making ice
just unscrewed the 3 screws, attached the rounded plug that came with the unit and screwed back only 2 screws. ice magic in about a couple of hours
16 of 22 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Stephen from Jupiter, FL
Parts Used:
WR23X10725
Difficulty Level:
A Bit Difficult
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Existing light switch was hard to remove.
The existing light switch was very hard to remove. I ended up having to grab it with a pair of pliers and pull it out. Once it was out, it was very easy to put in the replacement and it seems to be working fine.
14 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
debbie from chino hills, CA
Parts Used:
WR30X10093
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
icemaker developed a leak and froze over
My husband did the repair, and even though our refrigerator is roughly 20+ years old, he was able to adapt it to work in all the right spots and we now have ice cubes! I'm very happy we did not have to spend $2000 on a comparable refrigerator.
18 of 30 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Barry from Phoenix, AZ
Parts Used:
WR30X10093
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Ice maker ot making ice
First I replaced the double valve because the ice maker was not filling with water. It still did not work. Then I replaced the ice maker itself. This worked and was relatively easy to replace. I had to use the water fill "slide" from the old ice maker. The new one was too narrow and it leaked water into the freezer.
18 of 31 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Arturo from Killeen, TX
Parts Used:
WR02X11561
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
support clip broken.
After figuring out how to remove the old broken clip, replacement was easy. Had to use a small putty knife to open the release on the bottom underside of the clip(between the clip & the refrig) . By looking at the replacement piece it was easy to figure out.
16 of 25 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Frank from Harpers Ferry, WV
Parts Used:
WR51X10101, WR9X489, WR50X122
Difficulty Level:
Easy
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Pliers, Screw drivers
refrigerator compartment got warm
After a little research I realized my problem could be one or possibly two components of three that caused the problem. Instead of changing one at a time, I took another approach. I just bought and changed all three to save time and prevent having to do the job all over again. Each time I would have to melt the ice off of the cooling coils and this is time consuming and annoying having to melt the ice repeatedly. I put a very accurate thermometer in the fridge and have been monitoring it since I changed the components. After one week it seems to be working fine keeping the fridge at 34-38 degree F.