36358067893 Kenmore Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- James from Garland, TX
- Parts Used:
- WR51X442
- Difficulty Level:
- Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Screw drivers, Socket set
Refrigerator & freezer became warm.
Unplugged the refrigerator. I took all the food items out of the freezer, took out the ice bin and shelves. Then I unscrewed the back panel and removed it. The freezer coils were frozen over with ice. Then I used a large fan to thaw the ice and cleaned up the water with towels.
I unscrewed the old defrost heater at the bottom of the coil section, removed it and screwed the new defrost heater part in. I ended up using some dikes to cut the wiring midway up . ( I was going to use the new plastic plug that came with the new part, but it wasn't correct ). I spliced the wires together ( the color scheme was the same - pink to pink, blue to blue, etc), capped them , taped them with electrical tape, and I covered them with a corner from a sandwich bag and taped them a bit more to keep moisture out. Then I tucked the wiring up away from the coil section. I also spliced this little cylindrical part into the existing wiring harness and clipped it onto the copper tubing. ( I suspect this is the defrost timer, but I'm not sure ). After I removed the the old cylindrical little part, I noticed the cap was popped out of it. (it looked like it was damaged a bit ). Once I got all wiring tucked away and back in place, I put the back panel back on, plugged it back in. Voila'. Easy as pie. It's been running fine ( about a week now) ever since. I replaced the thermostat sensor first since that was the cheapest part, but it wasn't the problem. So I moved on to the defrost heater and that ended up being the bad part. I repaired my refrigerator for less than $100.00. Thanks PartSelect. You rock!
I unscrewed the old defrost heater at the bottom of the coil section, removed it and screwed the new defrost heater part in. I ended up using some dikes to cut the wiring midway up . ( I was going to use the new plastic plug that came with the new part, but it wasn't correct ). I spliced the wires together ( the color scheme was the same - pink to pink, blue to blue, etc), capped them , taped them with electrical tape, and I covered them with a corner from a sandwich bag and taped them a bit more to keep moisture out. Then I tucked the wiring up away from the coil section. I also spliced this little cylindrical part into the existing wiring harness and clipped it onto the copper tubing. ( I suspect this is the defrost timer, but I'm not sure ). After I removed the the old cylindrical little part, I noticed the cap was popped out of it. (it looked like it was damaged a bit ). Once I got all wiring tucked away and back in place, I put the back panel back on, plugged it back in. Voila'. Easy as pie. It's been running fine ( about a week now) ever since. I replaced the thermostat sensor first since that was the cheapest part, but it wasn't the problem. So I moved on to the defrost heater and that ended up being the bad part. I repaired my refrigerator for less than $100.00. Thanks PartSelect. You rock!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- GEORGE from ELIOT, ME
- Parts Used:
- WR30X10093
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Will not make ice
Bing , Bang, Boom.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mary from Langhorne, PA
- Parts Used:
- WR57X10051
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers, Wrench set
Ice Maker was leaking all over freezer compartment
Pulled out the fridge, took off the cardboard back. Get a nut driver instead of screwdriver (easier). TURN OFF WATER NOW. UNPLUG FRIDGE NOW. Removed one screw holding valve. Pulled off electrical connectors. Use two small adjustable wrenches to remove water lines. Tag the plastic tubes (I marked RED and BLUE). Grab the new valve and try to stuff it into the same space. Whoops ! Dang plastic housing protecting the electrical from the water is in the way. Have to cut most of it out to make it fit. By the way, DONT follow the instructions about take the bracket off the OLD solenoid. You don't need it. Just throw it away. Connect the wires (remember to use the adapters sent with the new solenoid) Mount the new solenoid (now that the plastic is out of the way) with the one screw (nut driver). Hook up the supply water line (wrenches). Hook up the plastic tubes (aren't you glad you marked them ?). The tubes just push into the new solenoid, no more threads. I just left the plastic nuts on the tubing. TURN ON THE WATER. Check your connections for leaking. Do this before plugging in the fridge. If OK, plug in the fridge. Run some water on the door, look in about an hour to see if cubes are making now. Put cardboard back on fridge. Push fridge back against wall. CONGRATULATE YOURSELF ON A JOB WELL DONE.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- david from frankston, TX
- Parts Used:
- WR17X4310
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
rusty auger and crusher broke
as simple as taking off 4 screws from door of old one and putting door on new one and putting bucket back in place
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from Lafayette, CA
- Parts Used:
- WR17X4310
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
The original ice auger jammed and destroyed the original icemaker
The replacement part was an exact fit and slipped right into the space where the old one was. No tools needed.
Was this instruction helpful to you?
Thank you for voting!
The two parts I replaced had rusted. Left rust chips in ice.
I carefully removed the screws and laid aside in order. Taking off the ice grinders was the trickiest part, but I had read before to make sure to keep them in order. Replaced two new parts and reassembled. Pretty simple, but just keep track of where each part goes.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Drew from Spring Lake, NJ
- Parts Used:
- WR57X10051
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers, Wrench set
Ice Maker wouldn't work, water tube freezing up, water leaking onto floor
My problem was that the tube from the water valve to the ice maker was freezing when the valve was malfuntioning and sending more water, causing it to back up and freeze in the reception tube. Then the plastic water tube from the valve to the freezer seperated and water was leaking onto the floor. By reading the repair storyies on the Partselect website I learned that the water valve was not working correctly and needed replacing. I ordered the replacement part on a Wednesday evening and had the part at my house via FEDEX on Saturday morning. It took me about 20 minuttes to complete the entire repair.
I had shut the water off to the valve and unplugged the refrigerator.
First I took the ice storage unit out of the freezer. I then unsrewed the ice making tray from the left side of the freezer. I lowered the unit to the shelve but did not disconnect the wiring. I then pulled the water reception tube that goes from the ice maker to the outside of the refrigerator on the top right rear. There was grozen water contained in the tube. I ran it under the sink and released the frozen water so the tube was clear. I reinserted into the tunnel it sits in and reattached it to the 90 degree plaqstic fitting in the outside of the right rear of the refrigerator.I reattached the plastic water hose from the water valve to the 90 degree fitting. I then reattached the ice maker in the freezer compartment.
Using a nut driver I removered the rear cardboard cover and insulation from the right rear side of the refrigerator. Using a box wrench I unscrewed and disconnected the copper water tube from the valve. I then removed the srew holding the water supply copper tubing to the refrigerator and removed the srew holding the water valve in place.
I removed the old valve from the back of the refrigerator.
I then took note of the electrical connections and transferred them to the new valve. I needed the two adapters(supplied) for the right side electric terminal.
I then transferred the water connection tubes. Take note one is larger than the other. On the old valve they screwed into the water valve with a compression nut. On the new valve you only needed to insert the plastic water tube into the right size hole and push. The comression connection is automatic and does not require the nut. ( I just pushed the nuts back on the tubing and left them). There is a plastic seperation piece on the new valve. I just twisted it loose and removed it. This allowed ease in positioning the valve and water tubes.
I then inserted the new valve into the right rear of the refrigerator and resrewed the unit to the frame using the nut driver.
I then re-attached the water supply copper tubing onto the nipple on the new valve and using a box wrench re-attached same.
I then turned on the water supply to the refrigerator and checked for leaks.
I then replugged the refrigerator into the electical outlet and started the ice maker cycle.
I waited to see that all was working correctly. i then re-attached the insulation and cardboard cover on the rear of the refrigerator and pushed the unit back into the wall space.
Everything is working great now!
I had shut the water off to the valve and unplugged the refrigerator.
First I took the ice storage unit out of the freezer. I then unsrewed the ice making tray from the left side of the freezer. I lowered the unit to the shelve but did not disconnect the wiring. I then pulled the water reception tube that goes from the ice maker to the outside of the refrigerator on the top right rear. There was grozen water contained in the tube. I ran it under the sink and released the frozen water so the tube was clear. I reinserted into the tunnel it sits in and reattached it to the 90 degree plaqstic fitting in the outside of the right rear of the refrigerator.I reattached the plastic water hose from the water valve to the 90 degree fitting. I then reattached the ice maker in the freezer compartment.
Using a nut driver I removered the rear cardboard cover and insulation from the right rear side of the refrigerator. Using a box wrench I unscrewed and disconnected the copper water tube from the valve. I then removed the srew holding the water supply copper tubing to the refrigerator and removed the srew holding the water valve in place.
I removed the old valve from the back of the refrigerator.
I then took note of the electrical connections and transferred them to the new valve. I needed the two adapters(supplied) for the right side electric terminal.
I then transferred the water connection tubes. Take note one is larger than the other. On the old valve they screwed into the water valve with a compression nut. On the new valve you only needed to insert the plastic water tube into the right size hole and push. The comression connection is automatic and does not require the nut. ( I just pushed the nuts back on the tubing and left them). There is a plastic seperation piece on the new valve. I just twisted it loose and removed it. This allowed ease in positioning the valve and water tubes.
I then inserted the new valve into the right rear of the refrigerator and resrewed the unit to the frame using the nut driver.
I then re-attached the water supply copper tubing onto the nipple on the new valve and using a box wrench re-attached same.
I then turned on the water supply to the refrigerator and checked for leaks.
I then replugged the refrigerator into the electical outlet and started the ice maker cycle.
I waited to see that all was working correctly. i then re-attached the insulation and cardboard cover on the rear of the refrigerator and pushed the unit back into the wall space.
Everything is working great now!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Tim from The Woodlands, TX
- Parts Used:
- WR17X11653
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Ice buildup. The Ice Machine was frosting over. Ice (due to frosting) would block the drop chute.
Unfortunately, the replacement part didn't come with instructions. The repair, nevertheless, was fairly straightforward. After removing the plastic parts that guide the ice through the door (by removing a few screws that attach the parts to the inside of the door), I was able to slip my hand into the ice maker dispenser and remove the old part. The part clips on. It is a tight fit through the funnel (from the outside of the freezer), however, and requires that the gasket first be "flipped" open wherein it unfolds 180 degrees. Doing this will make it easier to clip the new gasket onto the assembly.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from Divide, CO
- Parts Used:
- WR60X187
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
Fan had quit; needed replacement.
The fan was the correct part. It arrived one day after my well trained son-in-law had left for Texas. I had to install the motor myself. He had trained me well; it was not hard. the most difficult was getting the two tabs on the fan housing to fit back into the frame of the refrigerator where they belonged. Thanks. the part & delivery were overpriced, but I needed seed and convenience. Thanks for getting it right the first time.
John Moragues
John Moragues
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Eric from Rose Hill, KS
- Parts Used:
- WR57X10051
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Solenoid controlling the valve had stopped operating.
I first tested to make sure the solenoid was receiving power. Every time the arm on the ice maker cycled, the meter would go up to 120v for about 10-15 seconds, and then back to almost 0, so I knew the electical control and timer was working as it should.
The valve was easy to change - took about 20 minutes total (including pulling the fridge out and pushing it back in). I just turned the water off, removed the valve assembly from the fridge, and took all of the lines off of the old one. I then hooked up the supply line to the new valve assembly. The lines to the water and ice had compression fittings on them, but the new vavle has a "push-in" connector. So, I cut the old water and ice lines squarely, just past the fitting, then pushed them in firmly. Plugged the connectors in, re-attached the vavle assembly to the fridge, turned the water back on, and viola - I had ice in about an hour! Gravy! :)
The valve was easy to change - took about 20 minutes total (including pulling the fridge out and pushing it back in). I just turned the water off, removed the valve assembly from the fridge, and took all of the lines off of the old one. I then hooked up the supply line to the new valve assembly. The lines to the water and ice had compression fittings on them, but the new vavle has a "push-in" connector. So, I cut the old water and ice lines squarely, just past the fitting, then pushed them in firmly. Plugged the connectors in, re-attached the vavle assembly to the fridge, turned the water back on, and viola - I had ice in about an hour! Gravy! :)
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Bill from Columbiana, AL
- Parts Used:
- WR9X489
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
freezer not frezing properly frost buildup
Removed housing around timer. Unpluged and
replaced timer. Defrosted freezer witk small portable heater. Freezer has worked greater since.
Saved a lot on service call.
replaced timer. Defrosted freezer witk small portable heater. Freezer has worked greater since.
Saved a lot on service call.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- George from Louisville, KY
- Parts Used:
- WR17X3484
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Plastic light sheild over freezer light had broken.
Removed old sheild and reached in freezer replacing sheild with screwdriver. 3 - 4 minutes.
Ordered sheild online one afternoon and received the nest afternoon. Great transaction. will use again when needed.
George in Louisville, KY
Ordered sheild online one afternoon and received the nest afternoon. Great transaction. will use again when needed.
George in Louisville, KY
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from Lakeland, FL
- Parts Used:
- WR51X442
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
The regrigerator would not defrost properly. After doing some online research, I determined that the Defrost Heater was no longer working.
First, I had to remove the back panel in the freezer. This exposes the cooling coils and the Defrost Heater which is located toward the bottom underneath the cooling coils. There are four screws that have to be removed before the old Defrost Heater can be taken out. There are two wires that go from the Defrost Heater to the power connection. These wires are blue and pink. I had to remove some pieces in the back at the top of the freezer to expose the power connection for the Defrost Heater. These pieces were held in place with phillips screws, so they easily came out to reveal the power connection. The power connection is a simple plug-in type. The Defrost Thermostat is also included with the new Defrost Heater. This is a round piece which is clamped onto the Cooling Coils. I removed the old Defrost Thermostat. It is connected to the same power connection with the Defrost Heater. After I mounted the new Defrost Heater and Defrost Thermostat and connected the power, the refrigerator has worked perfectly.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Hop from Houston, TX
- Parts Used:
- WR9X489
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
Refrigerator compartment warm, Freezer cold
This is a old 2000 side by side Kenmore frig bought from sears. left Freezer side was building up ice in the back, while right side was not cool at all. The Defrost Timer was behind the light panel on top in compartment side. Easily remove unit and unscrew things. Works like a champ.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- donald from opelousas, LA
- Parts Used:
- WR60X187
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
noise from condenser fan
disconnect the power to the unit. remove the retainer sctrews on the mounting bracket. remove fan motor from unit. using the rerquired tools remove the fan from the old motor and install on the new one. torque the nut until all slack is out then 1/4 turn. reinstall motor assy. and reconnect power. test the system .