Customer:
Curtis from Pikeville, KY
Parts Used:
WPW10225581
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Pliers, Screw drivers, Socket set, Wrench set
Refrigeator would not drfrost...
I just removed a few screews and took the cover out of the ice box. Put my voltage meter to the refrigeator and realized the the unit was not defrosting...I then got the part number and entered it in on your web site. A few days later my part arrived. I put the part on and in just about 20 minutes I was up an running again...Thank you Part Select for fast and great service. I own 35 rental properties and having a online appliance parts store really saves me a lot of time and money.

Thank you
Curtis Hall
27 of 44 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Allan from Allen, TX
Parts Used:
WP2198202
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
refrigerator would not stay cold
The wife found if we tapped the knob for the cold control the appliance would turn on. Upon further inspection I found what looked to be carbon particles under the part. I found the part easily with partselect.com, ordered it, installed it and its like we have a new appliance.
21 of 26 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Greg from Cary, NC
Parts Used:
W10190935
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
ice would not fall from ice maker
I ran all the ice maker module tests that I could find online, I tried cleaning the contacts inside the ice maker control module, nothing worked...so I finally decided to purchase a new control module. I had already had the module out and taken apart a few times, so the new one was very easy to install. Just removed the entire icemaker from the fridge, removed a few screws, took off the old module, put on the new one, replaced the screws, re-installed the icemaker in the fridge (it just slides in and out similar to a shelf). And 30 minutes later I heard the first batch of ice cubes drop! And by morning the bucket was nearly full. After two weeks of no ice and trying to fix it myself - the family was glad to have ice again (it was July in NC!). In retrospect, I should have followed the advice I found online and ordered the new part sooner and saved all of those frustrating hours of trying to "fix" the part myself.
22 of 30 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Christopher from Redmond, WA
Parts Used:
W10822278, WP2198202
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
greezer started to thaw and would not refreeze
tested thermostat and defrost time but both tested as working...called a repairman who came in and said they were both working...got annnoyed for not trusting myself. Repairman did say that he had seen defrost timers simply slow down, allwoing them to tesat as good but not actually working correctly. I ordered both the thermostat and the timer to cover all bases...actual replacement was simple.
21 of 27 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
SAL from UPLAND, CA
Parts Used:
4387535
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Screw drivers
Refrigerator stop working
First I removed the relay and over load and exam. Saw that the relay was burnt. Before I order the part I check to see if the compressor was still working by jumping the common start and run terminals.It did. I also checked the start capacitor with a capacitor tester it was good. I than order the part which came the very next day.Installed the part
23 of 33 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Russell E from Rome, PA
Parts Used:
WP2315576
Difficulty Level:
Really Easy
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Pliers
Water was overflowing into ice bin.
First I ascertained that valve was faulty. Ordered replacement and installed without issue. Water now overflowed only during fill and found that filler neck had ice in it as a result of initial leakage. Defrosted with a hair dryer, removed ice plug and it now works as advertised.
22 of 31 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Michelle from Richardson, TX
Parts Used:
72017
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Scratches in Surface
This product comes in a bottle with a brush like Liquid Paper. It goes on incredibly easy. A second coat might be needed. I wanted to prevent rust from setting in so I covered the scratches and dings. The paint is a little brighter since my washer is 10 years old but it still looks great.
81 of 208 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
William from Springville, AL
Parts Used:
WP2315576
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Wrench (Adjustable)
Ice maker would not fill with water
Turn off the water supply.
Remove the two screws with a nut driver.
Disconnect the electrical connector.
Disconnect the water supply lines from the old valve.
Reconnect the water supply lines to the new valve.
(be sure to push the water line into the quick connect securely)
Reconnect the electrical connector.
Re-install the valve with the two screws.
Turn water supply on.
20 of 25 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Leo from Lewisport, KY
Parts Used:
WPW10151374
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
Unable to set the cold-control to a sufficiently cold setting.
Linkage on the cold-control mechanism in the air diffuser assembly was broken. It was necessary to access the diffuser assembly from both the refrigerator and freezer sides of the unit.
Re-connected the linkage between the diffuser and cold-control assembly; remounted the two combined assemblies . . . refrigerator working nicely now.
36 of 75 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
jesse from hacienda heights, CA
Parts Used:
W10823511
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers
Water began to leak under the refrigerator. Source looked like it was coming from control valve suppling water to ice maker and water dispenser.
Followed instructions supplied. It was relatively easy and the parts fit exactly right. Sears wanted twice as much for the part and service would have charged me another $100 to come to my home. I saved over $100 doing the project myself.
21 of 31 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
brett from garland, TX
Parts Used:
WP2198202
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
freezer intermitently warmed to around 31 degrees
Being a jet mechanic I had to familiarize myself with refrigerators, then after 2 or 4 hours of online studying, opened the door pulled the temp knobs of, removed the panel by gently prying the top of the panel out,then up and out with it. I found tapping on the thermostat shaft or wiring connection started the compressor, verifying my belief it was the thermostat. Don't mess with wiring if you don't know exactly what you are doing and unit is plugged in, you will electrocute yourself!!! I received the thermostat, UNPLUGGED THE UNIT from the house wall outlet, took one screw out of the upper inner wall at the very top to remove cover, one screw at the back top to remove the other cover (at the control vent) for access to remove sensor, then removed 4 screws , 2 front, 2 underneath to drop the housing for defrost timer, etc., and then took 2 screws from thermostat, unplugged wiring from thermostat (3 wires, be sure to put them back on the same place in the new thermostat). Remove old thermostat, slide plastic cover off sensor and slide back onto new thermostat sensor. Be careful not to kink the line or bend it to sharp you will damage it, (use gentle curves when bending it,) and re assemble everything in reverse order. This took about me 15 or 20 minutes start to finish. Plug into wall and watch thermometer to verify success.
16 of 17 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Dale from Flemingsburg, KY
Parts Used:
WPW10225581
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
It was not coming out of defrost cycle
First I installed a defrost timer, (the old timer had burnt out contacts in it) It seemed to work for a few days, then went back to not comng out of defrost cycle, I then installed a defrost thermostat. It seems to be working better than before. I found out that maybe I wasn't running it cold enough. So I turned it up colder. Now it works ok for 2 - 3 days, then I check the Temp in the freezer and its up to 6o. So I manually reset the timer and it works for 2 - 3 days. Don't know what to do now to fix it.
25 of 45 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ronald from DELRAN, NJ
Parts Used:
WPW10614158
Difficulty Level:
Difficult
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Screw drivers, Socket set
Water leaking from under refrigerator.
Water leaking from under refrigerator. Initially believed leak was from filter assembly. Removed filter and shut off water supply but leak appeared at different intervals again. Large puddle of water coming out from under refrigerator. Removed back lower panel and checked for leak, but didn't find any. My wife was also checking for leak and found a crack in drip tray. Only way we could get the drip tray out was to first remove front lower panel, disconnect and remove wiring harness in front of drip tray, unbolt water filter assembly, and unbolt water solenoid unit at rear of refrigerator. Their water lines connect to filter assembly. My wife controlled the water solenoid unit to give me play as I pulled the filter assembly out as much as I could from the front. I could now wiggle the cracked drip tray out from under the filter unit. Replaced drip tray and reinstalled wiring harness, water filter unit w/new filter, and re-bolted water solenoid unit at back of refrigerator. Replaced back lower panel after turning water back on and checking for leaks. Replaced front lower panel.

The reason still had leak after initially turning off water supply was because the drip tray is used to catch the water when refrigerator goes into the defrost cycle. Since the original drip tray had cracked, water only appeared on floor after defrost cycle.
15 of 16 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Joe from Pryor, OK
Parts Used:
W10190935
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Screw drivers
Following a brief power outage, it stopped producing ice. Harvester was at 6:00 with fingers frozen in ice cubes. Would make a batch if I freed the harvester and jumped the t-stat, but would quit again.
Unplugged refrigerator. Used nut driver to remove small bolt retaining wire cover on right side of ice maker. Removed wire cover, used flat head screw driver to depress side-rail clips. Ice maker slid out, unplugged. Timer module cover pops off easily. Three screws removed the timer module. Installation was reverse of removal. Had ice in less than an hour, bin was full by next morning. If you have a screw driver and know what it's for, this job should come easily.
18 of 26 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Kenneth from New Braunfels, TX
Parts Used:
WP2182124
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Ice stripper broken on ice maker
I unplugged the fridge. Loosened the 2 top screws on the ice maker and removed the lower screw. I disconnected the wiring harness and removed the Ice maker. I removed the plastic timer cover in front. I then loosened the screws on the face of the ice maker and removed the broken ice stripper and replaced it with a new one. Re-tightened the screws on the face, installed the timer cover, plugged in the wiring harness, re-attached the ice maker. Plugged the fridge back in and walla, it was making ice in 30 minutes!
17 of 24 people found this instruction helpful.