Customer:
Jim from Jacksonville, FL
Parts Used:
WR17X2059
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
crushed ice feature inoperative, broken pieces in water dispensed.
Found broken pieces of deflector in delivered ice. Removed dispenser, carefully disassembled it, marking fasteners, sprimgs, and levers. Local repaimen say no replacement part available, must replace entire ice maker @ $350. Found exact part in your online reference, ordered at price of $3.76, part arrived two days later--perfect fit, exactly same as original. Reassembled, and it works exactly like new. Family very happy. Good job!!!!!
6 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert from Orlando, FL
Parts Used:
WR55X129
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
ice being made but would not dispense
Easy repair. Snapped cover off control panel. Removed 4 phillips head screws on control board assembly. Removed (2) connectors from assembly and pulled out defective unit. Installed new control board in reverse order. Everything now working. Very fast and easy repair once you have the part.
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Dean from Folsom, CA
Parts Used:
WR30X10093
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
The Icemaker failed to make ice
I pulled the refrigerator away from the wall and turned off the water to the refrigerator and unplugged it from the wall. After removing the icebucket from the freezer I located the mounting screws, loosened them, unplugged the electrical connection below the icemaker and carefully removed it from the freezer. I unpacked the replacement icemaker, matched it against the original and attached the electrical connection adapter. Using the slots provided on the new icemaker I placed it over the mounting screws after aligning the water inlet pipe properly. I tightened the mounting screws while maintaining the icemaker in a level position. I plugged in the electrical connector. Then I replaced the icebucket, plugged in the refigerator back into the 110VAC outlet, turned on the water and repositioned the refrigerator in it's normal position.
8 of 16 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Charles from Rose Bud, AR
Parts Used:
WR50X122
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Wrench set
Refrigerat
rerfrigator side not cooling After determinating that the defrost timer was running I turned it to defrost and watched tosee if frost started to melt. When it didn't I checked the heater with ohmeter, checked OK, so the only other component in the defrost system is the thermostat. Then just a matter of cutting and splicing wires and snapping the new thermost in place
5 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Scot from Fort Collins, CO
Parts Used:
WR17X4358
Difficulty Level:
Difficult
Total Repair Time:
More than 2 hours
Tools:
Nutdriver, Screw drivers, Wrench set
Tubing from vavle to reservoir had been degraded by compressor heat and had cracked, leaking water when door water dispenser was used.
- Disconnect the valve assembly and remove electrical connection to water dispenser valve to prevent accidental water discharge

- Disconnect tubing from valve assembly, remove and keep compression nut.

-Disconnect tubing from junction to door tube remove and keep compression nut

-Remove screws used to mount reservoir, pull tubing into main refrigerator compartment and remove old reservoir and tubing.

- Note that one of the tubes on the new reservoir is 2' too short.

- Go to hardware store to purchase 5/16" universal tubing compression junction.

- Install reservoir and feed tubing through holes in main refrigerator compartment.

- Route tubing through woven tubing protectors and clips.

- Trim tubing to length and install in valve using old compression nut.

- Splice the piece of tubing trimmed from supply side of reservoir to the outlet side tube using the fitting purchased from the hardware store.

- Connect end of tubing to existing junction using old compression nut.

- Re-connect wires to valve solonoid and test for leaks.

- Re-install valve assembly to refrigerator frame.
6 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from Randle, WA
Parts Used:
WR32X1492
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
The vegetable pan was broken from closing the door on it too hard when still open
I just slide the new one in place, using exsisting sliders. I had to remove the old grab handle from old pan and snap it into place on new pan.
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Alan from Jonestown, TX
Parts Used:
WR55X129
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Pliers, Screw drivers
Water / Crushed Ice / Cubed Ice Switch Broken
Unplugged and shut off water. Popped off the face plate from below. Unscrewed 4 screws. Pulled out control board assembly. Pulled off two wire connectors. Unscrewed 2 screws to remove control board fastener. Replaced control board and reversed steps to assemble. When plugged in fridge, the switch was stuck on, so unplugged. Had to remove the rubber push plate and reassemble making sure the plastic lever was set properly in the control board. Reassembled and it worked properly.
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Kathrine from FORT MILL, SC
Parts Used:
WR60X187
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers, Socket set
There was a warm spot at the front edge of dividing wall. The fan motor was not working.
I followed the directions of Steve on the installation video. He makes it easy to do the repair with his step by step description of the installation. I have repaired three different aging appliances with help of Steve and PartSelect's very helpful Customer Service.
I wish Steve a wonderful retirement and hope PartSelect can find someone as easy to follow for future videos. The videos are priceless for the repairs.
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Charles from Inman, SC
Parts Used:
WR17X11653, WR2X8663
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Frost building up in ice shoot air leaking around door recess assembly
First disconnect power and turn off water supply.Removes the cover that indicates water and ice settings,removed 4 screws that held the switch assembly on,unplugged wiring harness (left solenoid wires connected.removed screw holding arm that closes door and removed assembly.Covered hole with duct tape ordered parts (which came very quickly turned water and power back on.When new parts came actuator arm was different on door put old one on door and reassembled in reverse order
7 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert from Philadelphia, PA
Parts Used:
WR62X107, WR2X8702
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Ice dispensing door would not function
I replaced the control board and the solenoid. This was very simple and easy to do. Make sure the power is disconneted before starting. I then removed the accuator pad and holder. Removed the face plate by simply pulling on it. I then removed the four screws holding the control board unit. I unplugged the unite by pulling the block connector on the left side. I then marked on paper the connections to the solenoid and unplugged it. I removed the three screws holding the solenoid the removed it. When installing the new solenoid make certain the rod to the dispenser is put into the solenoid plunger. Then replace the three screws and plug the wires back in using the connections written down on paper. I then removed the two philips screws on the control unit hold down bracket in order to remove the controll board. After removing the screws and the hold down bracket, I pulled the old board out and put the new one in. I then reinstalled the unit, faceplate, and accuator pad. I then turned the power back on and tested it. Worked like new, saving a lot of money...
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert from San Marcos, CA
Parts Used:
WR30X10093
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
no ice made
Performed self test.turned off ice maker switch four 5 minutes.Then turn on switch,within 10 seconds,pushed ice paddle 3 times,with 1 second in between each push.Push all the way back and release. Ice maker should cycle and squirt water. My ice maker did neither.I unplugged cord from fridge.So i replaced the ice maker.After a couple of screws had ice again !
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Christopher from Acworth, GA
Parts Used:
WR62X107
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Solenoid was hanging creating an awful noise when dispensing ice
Unplugged the refrigerator. Removed the panel to the ice/water dispenser. Removed the cover that displays ice type/water and light. Removed the 4 screws holding the cover. Unplugged the wiring harness to the cover which allowed easy access to the two electrical connections to the solenoid.
Removed the three bottem screws holding the solenoid in place. Loosened the top screw ( do not remove completely) and the solenoid slide down. Removed the solenoid arm that hangs on door latch.
Install hang solenoid arm on door latch; slide solenoid up under top screw. Install bottom 3 screws to hold solenoid in place then tighten top screw. Reattach electrical lines to solenoid then plug wiring harness back into cover. Install 4 screws holding panel in place. Re-install two remaining covers.
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Doug from MODESTO, CA
Parts Used:
WR02X11330, WR17X2891
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Pliers, Wrench (Adjustable)
Water line was leaking
The internal water line was leaking. I could not find any repair parts for my refrigerator but the GE 5/16 water line was the same size. I purchased 6' of tubing and two unions. Make sure the clean and square. If possible, make the cuts in a spot where you can use the pliers and wrench to tighten the union. I cut approximately 2' out of the existing line and replaced it with the same length of new line using the 2 unions, one on each end. Took about 5 minutes.
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Scott from South Lake Tahoe, CA
Parts Used:
WR17X4358
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Screw drivers
Dispenser Water Reservoir failed seem
This was a very easy fix. I cut the water lines at the reservoir, coupled the old lines to the new lines with two plastic barbed fittings used for outdoor drip irrigation. All I had to do was pull the old lines out and the new lines followed. Easy as pie!
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Bill from Great neck, NY
Parts Used:
WR51X443
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers, Socket set
DE Light on Display Panel
Evaporator freezing up. First changed the heaters. still freezing up. Ordered the timer. Removed the control's cover. Removed 1 screw, timer was fastedned with 2 screws, removed them, replaced with new timer. Problem fixed
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the 36358475892