Ice dispensing door would not function
I replaced the control board and the solenoid. This was very simple and easy to do. Make sure the power is disconneted before starting. I then removed the accuator pad and holder. Removed the face plate by simply pulling on it. I then removed the four screws holding the control board unit. I unplugged the unite by pulling the block connector on the left side. I then marked on paper the connections to the solenoid and unplugged it. I removed the three screws holding the solenoid the removed it. When installing the new solenoid make certain the rod to the dispenser is put into the solenoid plunger. Then replace the three screws and plug the wires back in using the connections written down on paper. I then removed the two philips screws on the control unit hold down bracket in order to remove the controll board. After removing the screws and the hold down bracket, I pulled the old board out and put the new one in. I then reinstalled the unit, faceplate, and accuator pad. I then turned the power back on and tested it. Worked like new, saving a lot of money...
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Charles from Inman, SC
- Parts Used:
- WR17X11653, WR2X8663
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Frost building up in ice shoot air leaking around door recess assembly
First disconnect power and turn off water supply.Removes the cover that indicates water and ice settings,removed 4 screws that held the switch assembly on,unplugged wiring harness (left solenoid wires connected.removed screw holding arm that closes door and removed assembly.Covered hole with duct tape ordered parts (which came very quickly turned water and power back on.When new parts came actuator arm was different on door put old one on door and reassembled in reverse order
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Scott from South Lake Tahoe, CA
- Parts Used:
- WR17X4358
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Screw drivers
Dispenser Water Reservoir failed seem
This was a very easy fix. I cut the water lines at the reservoir, coupled the old lines to the new lines with two plastic barbed fittings used for outdoor drip irrigation. All I had to do was pull the old lines out and the new lines followed. Easy as pie!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Doug from MODESTO, CA
- Parts Used:
- WR02X11330, WR17X2891
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Pliers, Wrench (Adjustable)
Water line was leaking
The internal water line was leaking. I could not find any repair parts for my refrigerator but the GE 5/16 water line was the same size. I purchased 6' of tubing and two unions. Make sure the clean and square. If possible, make the cuts in a spot where you can use the pliers and wrench to tighten the union. I cut approximately 2' out of the existing line and replaced it with the same length of new line using the 2 unions, one on each end. Took about 5 minutes.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Robert from San Marcos, CA
- Parts Used:
- WR30X10093
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
no ice made
Performed self test.turned off ice maker switch four 5 minutes.Then turn on switch,within 10 seconds,pushed ice paddle 3 times,with 1 second in between each push.Push all the way back and release. Ice maker should cycle and squirt water. My ice maker did neither.I unplugged cord from fridge.So i replaced the ice maker.After a couple of screws had ice again !
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Christopher from Acworth, GA
- Parts Used:
- WR62X107
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Solenoid was hanging creating an awful noise when dispensing ice
Unplugged the refrigerator. Removed the panel to the ice/water dispenser. Removed the cover that displays ice type/water and light. Removed the 4 screws holding the cover. Unplugged the wiring harness to the cover which allowed easy access to the two electrical connections to the solenoid.
Removed the three bottem screws holding the solenoid in place. Loosened the top screw ( do not remove completely) and the solenoid slide down. Removed the solenoid arm that hangs on door latch.
Install hang solenoid arm on door latch; slide solenoid up under top screw. Install bottom 3 screws to hold solenoid in place then tighten top screw. Reattach electrical lines to solenoid then plug wiring harness back into cover. Install 4 screws holding panel in place. Re-install two remaining covers.
Removed the three bottem screws holding the solenoid in place. Loosened the top screw ( do not remove completely) and the solenoid slide down. Removed the solenoid arm that hangs on door latch.
Install hang solenoid arm on door latch; slide solenoid up under top screw. Install bottom 3 screws to hold solenoid in place then tighten top screw. Reattach electrical lines to solenoid then plug wiring harness back into cover. Install 4 screws holding panel in place. Re-install two remaining covers.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Larry from Mount Airy, NC
- Parts Used:
- WR17X2059
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
would not crush ice
you must pay careful attention when taking the dispenser apart,especially the long rod that controls the deflector,but if close attention is payed to disassembly you should have no problem.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from Folsom, CA
- Parts Used:
- WR17X10401
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Broken Freezer Light Shield
Removed the one nut which holds the light shield in place, removed the old broken shield, secured the replacement shield with the single nut, and was finished in about 30 seconds. Easiest repair I'll ever make.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ravi from Rochester, NY
- Parts Used:
- WR55X129
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
The switch for the ice and water dispenser broke.
First I shut off the water supply and disconnected the power to the refrigerator. Remove the two finger tabs that are used to for the light swirch and ice/water by pulling straight down. Remove the cover to the dispenser assembly by pulling it out by hand. I removed the four small phillips head screw in each corner of the assembly. Pull the assembly out just enough to expose the circuit board connectors. Note the color of the wires and their position and location. The connectors are different sizes and should not be confused. Remove the two connector by pull them out straight. You can remove the entie assembly , but pay attention to the the water actuator when the assembly is removed entirely to prevent damage. Place the the dispenser assemby on a solid surface and remove the two screws holding the circuit board in place. Pay attention to the position of the black circuit board retainer be fore removing it. The circuitboard should be removed by pryiing gently on each side until it is released. Reverse the procedure for installation of the circuit board..
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Brian from Battle Ground, WA
- Parts Used:
- WR60X10262
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Socket set
Ice crusher not working
Remove the ice maker, motor and replace.
The biggest problem was that the part was NOT available from GE. Part Select had the part, it was easily identified on their website and it couldn't have been easier to order it.
The repair from GE would have cost me hundreds of dollars. Thanks Parts Select.
The biggest problem was that the part was NOT available from GE. Part Select had the part, it was easily identified on their website and it couldn't have been easier to order it.
The repair from GE would have cost me hundreds of dollars. Thanks Parts Select.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from PLYMOUTH, MA
- Parts Used:
- WR30X10093
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Socket set
Ice maker needed replacement
Unplug refridge then loosened two bolts holding old ice maker. Lower then unplug and removed. Plugged in new harness and tightened two bolts to secure new ice maker. Plug in frig and wait for ice.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mark from Indian Trail, NC
- Parts Used:
- WR02X11330, WR17X2891
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
5/16" tubing to chilled water dispenser cracked
Cut out cracked tubing between valve and where tubing enters into refrigerator. Cut new tubing to length and attach to existing using union.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Lynn from MOUNTAIN HOME, ID
- Parts Used:
- WR30X10093
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
Made ice would not eject from ice holder bin
removed broken bin , slid new ice bin in closed door. I bought the complete part.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Marie from Philidelphia, PA
- Parts Used:
- MWFP
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
replace filter
just had to unscrew old one put the new one in
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Delbert from LaFayette, GA
- Parts Used:
- WR55X129
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
lost crushed and then cube ice production
removed panel from front. removed old circuit. Replaced with new. It worked as hoped. Replacement doesn't get any better than that.