25331612100 Kenmore Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Salvador from SANTA ANA, CA
- Parts Used:
- 5303918202
- Difficulty Level:
- Very Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers
Freezer worked, refrigerator didn't. Ice build up on coils.
Unplugged refrigerator. Emptied freezer and removed ice maker and cover, need to unplug fan. Defrosted coils with hot water. Cut wires to thermostat as close to it ad possible to leave extra wire in case of an error. Stripped wire in new thermostat and put in shrink plastic then the wire crimp connector joining both light blue wires making sure wires were in before crimping them. Repeated with other dark blue wire. After used the heat gun to shrink the protective white tubing. The only thing i found not satisfying was tge tubing. It was too wide and too small. When i shrunk it did not cover the whole connector and was loose. I had to use a glue gun to cover both ends of each wire connector. Hope this helps other users.
Was this instruction helpful to you?
Thank you for voting!
Broken supports on door shelves needed replacement
This is super easy. You just pop the old supports off vertically, pull the bar off of the broken one(s), replace them with the new one(s), then pop the whole thing back onto the door of the fridge by pushing down on both sides.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- will from bushnell, IL
- Parts Used:
- 5303918202
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Freezer froze up/ Fridge ran warm
Thawed out freezer, I recommend laying a couple old towels in freezer to soak up melted ice. Replaced old thermostat with new part. Removed 2 screws, removed back plate, unplugged 2 connectors and cut 2 wires. Crimped in new thermostat and repositioned to original part location. Reconnected plugs as I reinstalled back plate. Installed 2 screws and connected power. Works like new! Trouble shooting and part installation video is very helpful, great site!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Donald from Okeechobee, FL
- Parts Used:
- 5303918549
- Difficulty Level:
- Very Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Intermittent loud noise coming from fan motor located in freezer compartment
Ordered a new evaporator fan motor and watched the repair video supplied by part select on their web site.It was spot on step by step instructions
Was this instruction helpful to you?
Thank you for voting!
I ordered the parts to replace broken ones, and they arrived.
There were no directions. Everything was self-evident. It was actually impossible to screw up, although the parts did not exactly snap together immediately. A bit of juggling and a bit of careful force (you don't want to break the plastic) was needed, but I prevailed!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from ABINGDON, VA
- Parts Used:
- 5304464438
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Fridge would not cool at all, because the compressor was not running. Fan running, lights working, just no cool.
Remove the cardboard access cover at the bottom back of the fridge. On the left side, locate the run capacitor. Remove it by prying it loose from its socket, after first removing the wire hold down clamp. One wonders why the clamp is there, which makes it difficult to get the run capacitor out. Be careful not to disrupt in any way the copper refrigerant tubes. If you mess them up, you will have wasted your time and effort trying to repair the machine. I was lucky, since a failed run capacitor is the problem only about 12% of the time, based on what I’ve read. Hallelujah! It was the problem with my fridge.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- JACOB from YOUNGSTOWN, OH
- Parts Used:
- 241537103
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
Refrigerator did not cycle
Installation was fairly straight forward. The major complaint is that the problem returned 2 weeks later. I don’t know if I care to re-invest in another switch.
Now what?
Now what?
Was this instruction helpful to you?
Thank you for voting!
Retaining bar was broke
Snap left and right end cap onto the retaining bar then snap onto the door
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Judy from ROYSE CITY, TX
- Parts Used:
- 5304464438
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
Freezer wasn't cooling - compressor not engaging
Ordered the Capacitor and the Thermostat Control. Parts were received in a matter of a few days, easy to install, but did not fix the problem. Had to call a repairman to fix the problem (compressor relay - this part not available to order for this model number with Parts Select). Will continue to use Parts Select in the future for other parts, but not happy that the actual part I needed was not available - had to use other methods.
Was this instruction helpful to you?
Thank you for voting!
door shelves were broken from use
simply replaced the pieces directly. It was very easy.
The different parts are easily deciphered and reassembled.
The different parts are easily deciphered and reassembled.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Marcos from E STROUDSBURG, PA
- Parts Used:
- 240362601
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Socket set
The Refrigerator was not cooling properly. At 40-45 degrees milk spoiled
My upper and bottom air diffuser was missing.
Purchased both air diffuser and placed it.
Purchased both air diffuser and placed it.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from VENICE, FL
- Parts Used:
- 5303918202
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Refrigerator evaporator coil was icing up
The evaporator coil is behind the freezer. Remove the rack that makes the shelf and remove two 1/4” hex head screws I the back of the freezer to access the coil.
I used a hair dryer to melt the ice off the coil.
The thermostat clips on the refrigeration pipe to the coil. Remove the old thermostat and cut the wires at least a few inches from the thermostat. Clip the new thermostat on the pipe and strip about a 1/4” of the wire ends. The electrical connectors (provided with the new part) must be crimped to connect the wires.
I used a hair dryer to melt the ice off the coil.
The thermostat clips on the refrigeration pipe to the coil. Remove the old thermostat and cut the wires at least a few inches from the thermostat. Clip the new thermostat on the pipe and strip about a 1/4” of the wire ends. The electrical connectors (provided with the new part) must be crimped to connect the wires.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- eddie from CHICAGO, IL
- Parts Used:
- 5303918202, 215846602
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Socket set
The refrigerator wasn't getting cold the freezer was getting to cold
Followed the installation instruction for both parts now both the freezer and refrigerator are getting cold
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Stephen from PERRIS, CA
- Parts Used:
- 5303918549
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Pliers
Fridge and freezer both freezing at bottom and warm at top.
Unplugged fridge. Removed freezer shelves and unscrewed and removed plastic shelf brackets. Removed the lower rear panel. Removed the bin for ice. Removed the 2 exposed upper rear panel screws. At this point I was able to flex the panel quite enough to access the fan motor. Carefully plugged the fridge back in and turned it on long enough to verify the existing evap. fan motor was not running. Powered off and unplugged again. Removed the fan and it's support assembly, and replaced with new. Had to cut the wires and splice and crimp with the provided wire nuts since the plugs in this model were different. Powered on fridge to check fan function. Reassemble and go home looking' like a hero! Saved my BFF a couple hundred bucks.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Denise from Landover, MD
- Parts Used:
- 316538904
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
light bilb went out
replaced it
Was this instruction helpful to you?
Thank you for voting!