36358092891 Kenmore Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Wendell Hayes from Dillob, SC
- Parts Used:
- WR60X187
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Fridge wasn't cooling and half freezing
Part was perfect fit .Removed fan .three screws.replaced that s it
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Gail from LEXINGTON, SC
- Parts Used:
- WR17X11653
- Difficulty Level:
- Very Difficult
- Total Repair Time:
- More than 2 hours
Thought flapper in ice dispenser was problem. - more serious, more costly - not a DIY! New fridge here we come!
Opened, discovered not flapper but more complicated
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Regina from Taylorsville, KY
- Parts Used:
- WR30X10093
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
icemaker quit working when we moved
My husband took out the old icemaker in about 5 minutes. The new icemaker was a perfect fit even though the refrigerator was >10yrs old. The only difficult part was the plug extension that was needed so that it would fit into an older appliance. The part was included, it just made the cord about 3 inches longer than it needed to. After working with it for about 20 minutes we were able to fit it on the back side of the icemaker. Now it works great!!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Walter from SANDIA PARK, NM
- Parts Used:
- WR17X3670
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
On the water dispenser line, the heat from the compressor unit had cracked the feed line, resulting in a leak.
I removed the plate covering the water valve for the ice maker and water dispenser, removed the nut holding the 5/16" tubing to the valve and took off the tubing and nut. I did not need to turn off the water supply or unplug the unit. I removed the kick panel in the bottom front of the refrigerator, replaced the existing plastic fitting with a new push-on fitting, then spliced the tubing coming from the water chiller to the valve where the leak was thus bypassing the broken tubing with new tubing. I reassembled the valve using the original plastic compression nut, replaced the cover and ran the water dispenser while checking for leaks. The water dispanser works great with no leaks.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Dan from HIGHLAND, MD
- Parts Used:
- WR29X5171
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
On/off switch stuck in the off position
Removed icemaker from freezer,
Removed 3 screws from cover plate, and removed screw securing main gear, removed gear.
Pulled back cover plate to expose switches and mechanism.
Removed screw holding switch to remove switch, and installed new switch.
I should have taken a pic of the cover plate, the interior mechanism and the wiring as I went along. It would have saved me 45 minutes in reassembly. Also, as luck would have it, I reversed the wiring on the switch. So off was on, and I had to remove it, switch wires and re-install.
But it works!
Removed 3 screws from cover plate, and removed screw securing main gear, removed gear.
Pulled back cover plate to expose switches and mechanism.
Removed screw holding switch to remove switch, and installed new switch.
I should have taken a pic of the cover plate, the interior mechanism and the wiring as I went along. It would have saved me 45 minutes in reassembly. Also, as luck would have it, I reversed the wiring on the switch. So off was on, and I had to remove it, switch wires and re-install.
But it works!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Karen from Gainesville, FL
- Parts Used:
- WR57X10051
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Wrench (Adjustable)
ice maker stopped working
I unplugged the refrigerator and shut off the water. I removed the back of the frig where the inlet valve is located. I removed the old nuts and cut the plastic water line on the ends. I shoved them into the new fittings. I then turned on the water and plugged in the frig. I could hear the water pumping into the ice maker. I screwed the inlet and back of refrigerator in place.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mark from Dumfries, VA
- Parts Used:
- WR57X10051
- Difficulty Level:
- Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Screw drivers, Wrench (Adjustable)
Water Valve Leaking
Removed lower cover screws removed cover removed copper water feed tubing connector unplugged wire connectors pulled out plastic water line connector and water lines removed water valve assembly installed water lines installed wire connectors secured valve assembly reinstalled copper water line turned on water valve checked for leaks reinstalled lower rear cover
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- George from Cun City Center, FL
- Parts Used:
- WR17X3909
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
The shield light had burned the shield
I hung the new shield on the two inside pegs that were already there.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Chester from Chambersburg, PA
- Parts Used:
- WR57X10051
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Wrench (Adjustable)
Valve leaked water and needed to be replaced
First I removed the incoming water line from the valve. I then removed the screw that hold the valve in place. Then I pulled the element out about 3 inches and disconnected the two connector wires. Next I cut the plastic hoses from the old valve.
To install the new valve, I inserted the two plastic hoses into the new valve. (hoses are different diameters so it is next to impossible to insert them incorrectly.) I replaced the electrical connectors (This was the only glitch since the one connector on the refrigerator is larger then the pins on the new valve, A little electrical tape held the connector in place.) I then tightened the screw that holds the valve on the refirgerator and reconnected the household water to line to the valve.
The entire job took less time then it has taken me to type the procedure.
To install the new valve, I inserted the two plastic hoses into the new valve. (hoses are different diameters so it is next to impossible to insert them incorrectly.) I replaced the electrical connectors (This was the only glitch since the one connector on the refrigerator is larger then the pins on the new valve, A little electrical tape held the connector in place.) I then tightened the screw that holds the valve on the refirgerator and reconnected the household water to line to the valve.
The entire job took less time then it has taken me to type the procedure.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- GARY from LIVONIA, MI
- Parts Used:
- WR17X11653
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Ice Maker Clogging up from frost build-up
Turn off power
Remove operator faceplate by pullling out on outer lower corners
Disconnect wire connectors from circuit board
Remove four screws from dispenser and pull out dispenser assy
Replcae Door ASsembly
Put everything back in place
Power up
Job Done
Remove operator faceplate by pullling out on outer lower corners
Disconnect wire connectors from circuit board
Remove four screws from dispenser and pull out dispenser assy
Replcae Door ASsembly
Put everything back in place
Power up
Job Done
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ken from Wesley Chapel, FL
- Parts Used:
- WR17X11653
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
froze in freezer
unclipped and replace with new part.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- joselito from riverview, FL
- Parts Used:
- WR17X11653
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Ice Building Up In The Ice Dispenser Chute
Under the control panel there are three small holes. Insert ballpen or small flat screw driver on both outer holes to push a tab lock that holds the control panel in place. Then pull out control panel and three set of wires will be exposed and disconnect wire connectors (connectors have different sizes so you wont get confused in reconnecting). Unscrew four screws on each corner that holds the ice dispenser assembly (a part where you push your glass against to dispense ice or water. The flapper is exposed and easy to replace.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from Chapel Hill, NC
- Parts Used:
- WR57X10051
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers
Leaking valve
The valve was leaking from the core and not the in/out tubes. The valve is easy to get to and very easy to replace. When replacing the water in/outs you cut them off the old valve and then slip them on the new valve. 5 to 10 minute job.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Craig from Land O Lakes, FL
- Parts Used:
- WR57X10051
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers
Water flow was too low
Turn off water valve to the refigerator and disconnect line.
Remove the cardboard backing and insulation.
Remove old valve and cut lines close to the valve.
Trim plastic on new valve as needed to fit (generic valve).
Insert water lines into new valve.
Install new valve.
Connect water line and open valve.
Replace cardboard backing and insulation.
Remove the cardboard backing and insulation.
Remove old valve and cut lines close to the valve.
Trim plastic on new valve as needed to fit (generic valve).
Insert water lines into new valve.
Install new valve.
Connect water line and open valve.
Replace cardboard backing and insulation.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Al from River Edge, NJ
- Parts Used:
- WR17X11653
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Ice maker discharge was slow and jammed with ice and frost. The cause was a distorted flapper that did not seal properly, admitting warm air into the dispenser chamber.
Excellent video was available on the Parts Select website. It was simple. The selector panel pulled out by hand from the bottom. The subpanel was removed with the four screws. The flapper snapped out of the holder with two clips. The new one was inserted in reverse order.
Was this instruction helpful to you?
Thank you for voting!