Customer:
Paul from Ashton, MD
Parts Used:
WR2X7905, WR2X4550, WR2X4141, WR2X4140, WR2X4139, WR17X2058
Difficulty Level:
Difficult
Total Repair Time:
More than 2 hours
Tools:
Pliers, Screw drivers
bucket drive shaft disengaged from motor drive
This is a 25 year old unit. The ice bucket had warped over time causing the face plate to move forward of its ideal position pulling the entire assembly out of the drive. Removed dispensing unit face assembly. Removed drive shaft assembly. Replaced all washers. Reversed old broken drive cup. Married old drive cup to new drive cup...lining up drive slots. Drilled 6 ea. 3mm holes evenly spaced around circumference into the face of the old drive cup. Fastened drive cups together in vice and with C clamp...then using phillips head screws installed 3 ea. from opposing entry points on each side of this homemade shaft extender. This "mechanism" increased the effective length of the dispensing shaft assembly allowing for a proper fit of the drive shaft to the motor drive connection. Unit now works perfectly. Total cost @ $40.00 and two hours work which would have taken less than one hour if I had remembered to install the ice bucket seal the first time. New ice bucket would have cost @ $185.00. Home warranty does not cover ice makers or any of the associated parts. DIY...it isn't that difficult.
12 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Sarah from Burton, MI
Parts Used:
WR50X122, WR17X3484
Difficulty Level:
Really Easy
Total Repair Time:
1- 2 hours
Tools:
Screw drivers, Socket set
Freezer would not auto defrost. Food side would be warm.
Your customer installation comments were very helpful. After unplugging the unit, I took out all the freezer shelfs and the back panel (4 screws). I hadn't realized the coils were also covered in solid ice. It took awhile to defrost with a hair dryer, and I needed to use more than one towel to soak up the melting ice. Locating and splicing in the new thermostat was very easy. I used "cold weather" electrical tape to splice the wires back together. After reassembling the back panel and shelfs, I snapped in a new light shield that had been broken for awhile. It's been over a week now, and I do not see any problems. Overall, it was a easy fix. Just took a little time to defrost the coils.

Sarah
10 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mark from Somers Point, NJ
Parts Used:
WR23X37285
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers, Screw drivers
Switchlight was broken on tennant's refridge
as described, I used a thin screwdriver to wedge in and pull down existing, broken switch. I was able to pull it down about a 1/4 inch, but wasn't quit able to disegage it until I gripped it with pliers. I then pulled it out, unplugged the old switch, plugged in the new switch, and carefully tucked the wires back into the fridge and snapped the new switch into place.

10 minutes total.
10 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Gilbert from Tucker, GA
Parts Used:
WR57X10026
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Wrench (Adjustable)
Leaking inlet water valve
Disconect and Removed cover from back of frig.
Removed water supply pipe (adjustable wrench).
Removed Bracket and Valve Assembly from frig (1 screw).
Marked tube placements with marker so that I could put them back correctly.
Removed power connectors from valve.
Disconected tubes from valve (not that easy to pull off).
Connect tubes on new valve. Plug power connectors back in.
Screw the Assembly back on the frig.
Reconnect water supply & test for leaks.
10 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
GEORGE from ELIOT, ME
Parts Used:
WR30X10093
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Will not make ice
Bing , Bang, Boom.
13 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
david from frankston, TX
Parts Used:
WR17X4310
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
rusty auger and crusher broke
as simple as taking off 4 screws from door of old one and putting door on new one and putting bucket back in place
8 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Tim from The Woodlands, TX
Parts Used:
WR17X11653
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Ice buildup. The Ice Machine was frosting over. Ice (due to frosting) would block the drop chute.
Unfortunately, the replacement part didn't come with instructions. The repair, nevertheless, was fairly straightforward. After removing the plastic parts that guide the ice through the door (by removing a few screws that attach the parts to the inside of the door), I was able to slip my hand into the ice maker dispenser and remove the old part. The part clips on. It is a tight fit through the funnel (from the outside of the freezer), however, and requires that the gasket first be "flipped" open wherein it unfolds 180 degrees. Doing this will make it easier to clip the new gasket onto the assembly.
9 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
James from Lafayette, CA
Parts Used:
WR17X4310
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
The original ice auger jammed and destroyed the original icemaker
The replacement part was an exact fit and slipped right into the space where the old one was. No tools needed.
8 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from Jupiter, FL
Parts Used:
WR17X4341, WR17X2760
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers
The two parts I replaced had rusted. Left rust chips in ice.
I carefully removed the screws and laid aside in order. Taking off the ice grinders was the trickiest part, but I had read before to make sure to keep them in order. Replaced two new parts and reassembled. Pretty simple, but just keep track of where each part goes.
9 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Bill from Columbiana, AL
Parts Used:
WR9X489
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
freezer not frezing properly frost buildup
Removed housing around timer. Unpluged and
replaced timer. Defrosted freezer witk small portable heater. Freezer has worked greater since.
Saved a lot on service call.
7 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Greg from Eden prairie, MN
Parts Used:
WR57X10023
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Socket set
Water Leaking from behind refrigerator
Turn off water to the refrigerator and unplug from wall outlet remove the defective inlet valve replace with new inlet valve. Now is a great to clean use a air compressor and vacuum and your old crusty frige will be good as new ! Special thanks to Parts Select fast shipping and original ge parts!!
13 of 25 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
George from Louisville, KY
Parts Used:
WR17X3484
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Plastic light sheild over freezer light had broken.
Removed old sheild and reached in freezer replacing sheild with screwdriver. 3 - 4 minutes.
Ordered sheild online one afternoon and received the nest afternoon. Great transaction. will use again when needed.

George in Louisville, KY
7 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from Tampa, FL
Parts Used:
WR57X10023
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
leaked
replaced water valve for 50 dollars, saved about 200 dollars by doing it myself
8 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Curt from Selma, NC
Parts Used:
WR51X10101
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
Stopped cooling
Removed panel from inside the back of the freezer section, by removing four screws. Then, sprayed the ice build-up on the coils, with hot water until all of the ice was melted away. (Note: be certain to plug the drain hole, and use several towels to catch the water drainage. ) Removed the Defrost Heater Element by removing two holding screws. Unplug the unit and pluged-in the new unit and replaced all screws as originally mounted.
8 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Hop from Houston, TX
Parts Used:
WR9X489
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
Refrigerator compartment warm, Freezer cold
This is a old 2000 side by side Kenmore frig bought from sears. left Freezer side was building up ice in the back, while right side was not cool at all. The Defrost Timer was behind the light panel on top in compartment side. Easily remove unit and unscrew things. Works like a champ.
7 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the 36350247000