36358272893 Kenmore Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Timothy from West Windsor, NJ
- Parts Used:
- WR57X10051
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers, Wrench set
Replace Dual Inlet Water Valve
Unplug the electrical power to the refridgerator, remove old valve, marking which electrical wire set goes to which solenoid valve. Cut the nut fasteners from the ice maker and front door water tubes. Leave the nut fastener on the supply line.
New valve - remove plastic shipping protection guard, remove rubber cap from supply connection, bend mounting bracket to a 90 degree bend, attach electrical wire reducers to the small wattage solenoid wires then to the solenoid, attach large wattage solenoid wires to the large solenoid, push ice maker tube into the small quick-connection(no nut fastener needed), push the front door water into the large quick-connection, finally mount valve asembly using same holes in frame as held the old valve assembly. Plug in the power. Solenoid valves may take an hour or so to operate.
New valve - remove plastic shipping protection guard, remove rubber cap from supply connection, bend mounting bracket to a 90 degree bend, attach electrical wire reducers to the small wattage solenoid wires then to the solenoid, attach large wattage solenoid wires to the large solenoid, push ice maker tube into the small quick-connection(no nut fastener needed), push the front door water into the large quick-connection, finally mount valve asembly using same holes in frame as held the old valve assembly. Plug in the power. Solenoid valves may take an hour or so to operate.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Laura from Manchester, NH
- Parts Used:
- WR02X11330
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Moving the refrigerator into my new (very old) house we had to remove the doors which resulted in a crimped hose and union
Remove lower front panel, disconnect damaged union from water hose under freezer door, replace with new union, tighten and reattach front panel. No more water coming from under the unit. Ice maker and dispenser features returned to working order!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Wayne from Magnolia, TX
- Parts Used:
- WR51X442
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
The refrigerator section of my side by side was not getting as cold as it should have been.
It was easy after finding PartSelect online. It wasn't obvious at first that my evaporator core(in back of freezer side) was frosting over, (since I have a flat white panel that is about 8 x 30 inches covering it), until I reached inside and ran my fingers over the cover and noticed a thin layer of frost on it. At this point I told my buddies to go get ice for our beer cuz I was fixin to do a lock out/tag out on the Fridge. Seriously, Do disconnect the electrical power before taking it apart. After taking the 9 screws (6-1/4" hex heads & 3-#2 phillips)out and removing the panel, I saw that the evaporator core was completely frosted over. I then put a large towel in the bottom and let it thaw for a day. Next day after getting the old Defrost Heater Kit with Thermostat out (4-#2 phillips, plug-in electrical connection, thermostat snap on clip) , I noticed it was burnt inside the filaments and did not pass the continuity test. I then ordered my part from PartSelect and took the oppurtunity to clean my fridge spotless. 3 business days later, I received my part, installed it, and now have a "like new" refrigertor. Actual repair time - 30 minutes, Overall down time - 4 days, Saving the cost of a new Fridge - a heck of lot more beer!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- JEFF from HAMPTON, GA
- Parts Used:
- WR60X187
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
fridge quit coolingg / freezing
remove lower back cover - disconnect wires to fan motor - place 6" fan to blow on condenser - fridge began cooling & freezing again - ordered part - part arrived - removed fan motor & bracket - cleaned brackets & fan blade - cleaned lint & dust from condenser compartment (took longer to clean than anything else) - replaced fan motor - replaced cover - was hero with wife ... :-)
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Marion from Palm Coast, FL
- Parts Used:
- WR30X10093
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Refridgerator Freezer stoped making ice
Turned off power, removed cover from Ice maker, checked resistance across thermostat for zero (read open), all other switches read proper value (when activated). Ordered and received thermostat. Removed Ice Maker from freezer, removed two screws holding ice tray to Control Assembly. Removed Thermostat and replaced with new one. Applied Silicone Sealant to face of Thermostat for adhesion to ice tray when assembled. Remounted Ice Tray to Control Assembly and remounted in freezer. Works Great...
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Scott from Columbus, IN
- Parts Used:
- WR57X10051
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers, Wrench set
water valve leak
This Valve Has 2 Different Size Water Lines Going In To It And They Are Different Diameters.Each Has Its Own Collar That Locks The Lines Into It. Make Sure That You Put The Right Size Collar Over The Line Before You Insert It Into The Valve, Because Once You Put The Line In You Cant Pull It Back Out Without Messing Up The Valve. Make Sure It Is Right Because You Only Get One Shot At It.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jimmy from Palmer, TN
- Parts Used:
- WR50X122
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Defrost Thermostat quit working
Take the back panel off inside of freezer side. Cut the wires off old Defrost Thermostat and strip the ends. Attach the wires of the new one and tighten with wire nuts. Put back panel back on.
Was this instruction helpful to you?
Thank you for voting!
The auger was chromed steel. It rusted causing rust to get on ice.
It's a good idea to take closeup pictures, that will eliminate guessing when you put it back together. There was no instructions. I was happy to see GE knew there was a problem with the chrome auger. The replacement is STAINLESS STEEL.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Robert from Auburn, AL
- Parts Used:
- WR30X10093
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Ice machine wasnt making ice
First I turned the refrigerator and water line off. Then moved to the freezer section, followed the directions, removed the two screws. Directions state to not remove them but I had to in this case. Unplugged the ice maker and removed it from the freezer. I installed the two mounting screws then tried to plug the electrical connection back in but had to use the adaptor cord furnished in the kit. The cord was a little long but I tucked it in and mounted the ice maker. Turned it on then turned the refrigerator and water back on and in a few hours had ice! Very easy to do!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Greg from Vicksburg, MS
- Parts Used:
- WR51X442
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Screw drivers
Ref/frig not cooling
Removed the 4 screws holding the back panel in freezer compartment and then removed panel. Removed the 4 screws holding defrost heater and removed it. The replacement parts fit perfect , plug the new part in and bingo my frig is operating like a new one. Took about 15 minutes to make the repair. Took longer to defrost the ice buildup on the coils ( 1hr ) than to do the repair (15 min). I can't believe i would have been paying an appliance repairman to hold a hair dryer for an hour. Your diagrams showing where the various parts are located on the appliance are invaluable. Would recommend PartsSelect to anyone and I am sure that I will be ordering parts for my other appliances as needed. Thanks
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- TIM from GRETNA, LA
- Parts Used:
- WR2X4550
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Ice Maker Cap Broke
It took me about 15 minutes to complete the repair, 1st I emptied the ice maker, then I removed 4 screws from the rear of the ice maker tray and took the plastic piece off of the auger. I reversed the steps and put it back together.
Was this instruction helpful to you?
Thank you for voting!
Freezer would not auto defrost. Food side would be warm.
Your customer installation comments were very helpful. After unplugging the unit, I took out all the freezer shelfs and the back panel (4 screws). I hadn't realized the coils were also covered in solid ice. It took awhile to defrost with a hair dryer, and I needed to use more than one towel to soak up the melting ice. Locating and splicing in the new thermostat was very easy. I used "cold weather" electrical tape to splice the wires back together. After reassembling the back panel and shelfs, I snapped in a new light shield that had been broken for awhile. It's been over a week now, and I do not see any problems. Overall, it was a easy fix. Just took a little time to defrost the coils.
Sarah
Sarah
Was this instruction helpful to you?
Thank you for voting!
Freezer was cold but refrigerator was hot
After diagnosis though Part Select I determined it must be the defrost heater. I took the panel off on the inside of the back wall of the freezer and used a hair dryer to thaw the ice buildup. I found the bottom element was burned out. I ordered the defrost heater kit and the defrost timer in case that was faulty too. Parts arrived next day. I installed the heater kit and replaced the panel. Then took off the plastic cover inside the refrigerator. One screw near the top of the metal box allows you to remove it to get to the defrost timer.
Was this instruction helpful to you?
Thank you for voting!
bucket drive shaft disengaged from motor drive
This is a 25 year old unit. The ice bucket had warped over time causing the face plate to move forward of its ideal position pulling the entire assembly out of the drive. Removed dispensing unit face assembly. Removed drive shaft assembly. Replaced all washers. Reversed old broken drive cup. Married old drive cup to new drive cup...lining up drive slots. Drilled 6 ea. 3mm holes evenly spaced around circumference into the face of the old drive cup. Fastened drive cups together in vice and with C clamp...then using phillips head screws installed 3 ea. from opposing entry points on each side of this homemade shaft extender. This "mechanism" increased the effective length of the dispensing shaft assembly allowing for a proper fit of the drive shaft to the motor drive connection. Unit now works perfectly. Total cost @ $40.00 and two hours work which would have taken less than one hour if I had remembered to install the ice bucket seal the first time. New ice bucket would have cost @ $185.00. Home warranty does not cover ice makers or any of the associated parts. DIY...it isn't that difficult.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ernest W. from Charlotte, NC
- Parts Used:
- WR30X10093
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Screw drivers
Ice maker Stripper lost a tooth
First turn off the power, remove the ice tray, remove the two screws holding the ice maker to the side of the freezer, use the screw driver to gently open the electrical clip for the power cord inside the freezer, remove the complete unit from freezer, bend the old stripper from the holding pin- it is flexible- it will bend, replace the new stripper on the holding pin and bend into the slot to hold it firmly, no water will come out from the fill cup into the freezer, plug in the power cord, mount back to side of freezer, you are done.
Was this instruction helpful to you?
Thank you for voting!