Customer:
Carlos from Sierra Madre, CA
Parts Used:
5308000086
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Refregerator drain pan was cracked
The drain pan fit to perfection on our Frigidaire refrigerator model FPE19V3AW1 from 1987(!!!).
Was this instruction helpful to you?
Thank you for voting!
Customer:
Kenneth from Glenmoore, PA
Parts Used:
5300158289
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Refridgerator compartment warm but freezer frosty
First I replaced the defrost thermostat, then I realized that the evaporator fan would stop turning periodically. I could restart it by spinning the fan with my finger. The fan is behind a cover in the back of the freezer. If you remove the cover and check on the fan when you hear the condenser fan in the back running. (They seem to run at the same time.) It was easy to replace the fan and the new one is more powerful than the original. The refrigerator runs fine now. Thank you for this great site. Saved me a lot of $$.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Donald from Waynesburg, PA
Parts Used:
5300158289
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Fan Motor Malfunction
Followed the instruction video. Removed the old one. Attached the fan blade, ground wire and connected power plug. Reinstalled with 2 screws. Works great.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Wayne T from Galway, NY
Parts Used:
5303917954
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Pliers, Screw drivers
Freezer was not defrosting thus refrigerator was not cooling
1. Unplug the refrigerator.2. Remove the storage rack and back panel in the freezer. 3. Locate the thermostat. 4. Defrost the freezer coils , i used a hair dryer. 5. Remove the thermostat from the cooling coil and then clip the connecting wires close to the unit. 6. Strip the ends of these wires and connect these wires to the wires of the replacement unit using the supplied wire connectors. 6. Heat seal with a lighter the connections using the water shield sleeves provided and further wrap connections with electrical tape. 7. Reconnect the thermostat to the cooling coil at the location it was removed from. 8. Replace the freezer back panel removed earlierand the storage rack if you have one. 9. Plug the freezer back in. My refrigerator has been working ever since the repair. There are several YouTube videos available that walk you through the diagnoses and repair process. They are very good.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Guillermo from Miami, FL
Parts Used:
5303917954
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Freezer iced up, fridge section warm
After reading other posts, I decided to change the defrost thermostat, so I watched the videos, and did that. It got better, but the problem persisted, and the ice was still building up in the freezer section. So I decided that the problem was with the defrost heater. I ordered a new one, that was here under 24hs (using the Fedex ground). I replaced it, measured the old one and saw that it was not passing any current at all (so it was really burnt). Now the fridge is good as new, maintaining the proper temperatures both at Freezer and Fridge sections. Thank you Parts Select ! With $ 70 in parts I was able to get back my appliance working !!!
Was this instruction helpful to you?
Thank you for voting!
Customer:
gustavo from gilroy, CA
Parts Used:
5300158289
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Socket set
Fridge was warm and no cold air was coming in
The repair was straightfoward. The evaporator motor I received from partselect was a different model with different wiring configurations. I cut the wires from the new motor per the instructions I received with the new motor and I did the same with the wires that connect to the fridge. Once I matched the wires and secured them with electrical caps I began to put the evaporator motor to the base and started screwing the screws the way I took them off. Once I connected the wire harness to the back of the freezer and turned it on I noticed a big difference in air flow. I was surprised at how easy it was to fix my refrigirator problem. It's been a few weeks now and the fridge is cold and working like it should. Don't be afraid of this task. it's very easy and will save you a ton of money. Thanks partselect.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Susan from Rapid City, SD
Parts Used:
218906802, 316538904
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
My Frig Light Stopped
I am a 65 year old woman with no mechanical aptitude: I just unplugged the frig. And used a screw driver to pry of the plastic socket from its outside edge. . Then you just unplug two tiny contact plugs that appear when you pull out the socket and replug in those two the same way on the new part. Pop the socket back into the hole . . . . And screw in the new bulb. I knew I needed the socket part cause when the bulb burned out , a new bulb still did not work. . . If I can do it, anyone can!
Was this instruction helpful to you?
Thank you for voting!
Customer:
Armando from Eagle pass, TX
Parts Used:
5300158289
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
the evaporator fan same time won't stater
change the evaporator fan motor kit working perfect
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from Hoopeston, IL
Parts Used:
215846604
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Screw drivers
Defrost Timer Stuck On Defrost (Again)
I went online to a you-tube video to assess the problem and watch the repair. Ordered the part on sunday before christmas and had it christmas eve! Easy 10 minute repair. Four screws held the cover on. Two screws held the timer. Unplugged the old timer an replaced. Put all the screws back and . . . . Done! Easiest repair I've ever done. Parts select did a great job, good price, very fast service! One happy customer!
Was this instruction helpful to you?
Thank you for voting!
Customer:
Joseph from New Ringgold, PA
Parts Used:
5300158289
Difficulty Level:
Difficult
Total Repair Time:
1- 2 hours
Tools:
Nutdriver
Replace evaporator fan motor.
Replace evap fan motor. Take a close-up picture of the evaporator fan motor installation prior to removing. Take pictures as removing various components.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Paul from Hicksville, NY
Parts Used:
215846604
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Screw drivers
Fridge section not cold enough, Frost in freezer
Very easy to do, as per the video instructions.
Was this instruction helpful to you?
Thank you for voting!
Customer:
BILL from GENOA, WV
Parts Used:
5303917954
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Refrig unit was frosting up top and bottom, did not properly defrost and stop cooling especially in lower compartment.
Unplug the refrigerator unit from wall. I removed freezer rack, plastic light cover, the ice rack shelf on the right side, then removed the plastic back cover panel, (4) retaining screws, gently tilting the panel toward me, unplug the wiring harness by depressing the clips on the side of the plug, removed panel from unit, set aside. If the unit was froze up, so I defrosted the cooling coils carefully with a common hair dryer until it was thawed. Be careful not to touch or bend the coils , since they are very fragile and SHARP! I located the old thermostat unit attached to a straight length of coolant line. The new unit looked like the old one, so it was easy to locate. I cut the two wires of the old unit close to the round base to make sure I would have enough wire to reconnect. Since my new unit did not indicate a polarity(Neg or Pos), I just wired each wire I cut to one of the new unit. I used the shrink tubing provided and heated the shrink till it was fully melted. I double ck'd to see if the wires were basically waterproof and a good connect. Also, before I replaced the rear panel, I made sure that both wires I had spliced had a drip loop to it so water would not drip down into the newly spliced union. Also made sure the wires will not interfere with the colling fan on the back of the rear panel. Reverse the procedure in reassembling. Plug in unit, and wait and listen for the unit coming back on..I kept a regular thermometer in the upper and lower compartments. Allow 24 hrs. for the unit to return to normal operation. It may defrost several times till the whole operation is back in sync.
Was this instruction helpful to you?
Thank you for voting!