Customer:
Darrell from Bentley, ND
Parts Used:
5300158289
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
the evaporator fan quit when we had a power surge
A screw driver was used to remove two screws that held the old fan in place the new fan ws installed exactly where the old one came out and presto the job was complete. No major deal.
5 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
ANGELA from MEBANE, NC
Parts Used:
316538904
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Refrigerator Light bulb went out
I replaced the bulb using my hands to twist the bulb in the socket located at the top of the refrigerator.
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mark from Partlow, VA
Parts Used:
5300158289
Difficulty Level:
Very Difficult
Total Repair Time:
30 - 60 mins
Tools:
Socket set
Motor squeal
I didn’t do the repair because the new motor had a female pigtail connector while the original motor has male connection. It came with wire clamps but didn’t want to cut wires to make repair. The pictures online show a male connection. Put the old motor back in and now it works fine.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
William from BASKING RIDGE, NJ
Parts Used:
215846604
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Screw drivers
Refrigerator had not been cooling
Discovered the coil was covered with 1/2 inch of ice because defrost cycle had not been working. Replacing the defrost timer and melting ice with hair dryer fixed problem. Hooray!
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Carol from OSHKOSH, WI
Parts Used:
5303917954
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
freezer was warm
Top freezer took off the panel in freezer and melted the ice around coils and found the defrost thermostat and replaced with the new one. Just followed the instructions from your video on line. Freezer works just fine now. Refrigerator is 38 years old.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jerry from PHOENIX, AZ
Parts Used:
5300158289
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Socket set
Freezer was freezing but refridgerator was warm. Checked fan and it was not turning.
Unplug fridge. Removed 2 nuts to get the vent plate off and two more nuts to get the motor mount off. Removed fan blade and then the fan motor. I put the new motor in and put everything back as it was. It was very easy. I had items in the freezer, so I didn't turn the fridge off other than to replace the part. It took about 6 hours for the fridge to reach optional temps because I didn't get to defrost and the fridge had to work it out on it's own. If you don't need the freezer then you should turn the refridgerator off for at least an hour and open the doors so the coils can defrost and any ice blockage between the freezer and fridge portion can melt away as well.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Alan from SAN MATEO, CA
Parts Used:
316538904
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Repaired Oven Range Light Bulb
The bulb has a plastic clear cover. That cover can just be carefully removed using a screwdriver. It's held in by a metal bracket. After you remove the cover. You'll just need to replace the bulb and then re-install the cover and bracket.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
gary from ARANSAS PASS, TX
Parts Used:
5308000010
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
I had a broken fan blade due to ice build up from a leaking ice maker.
1. I took out one screw on the ice maker and loosened the other two screws and unplugged and removed the ice maker.
2. Next I took out 2 screws from the bottom of the auger drive box and unplugged the wiring harness and removed the box. The wiring harness was a little tricky. The lock on the plug pushes in to unlock even though it looks like it pulls out,.
3.next you must remove 2 screws from the left side bracket that holds the auger box and remove the bracket.
4.Now take out 8 screws that hold the back panel in place and remove the back panel.
5. now your looking at the evaporator fan blade and motor. The simple way to replace the fan blade is to unplug the motor and remove it from the freezer. It just sits in with nothing holding it. The fan requires a little pressure but should pull right off. Install new fan blade and put everything back in the same order it was removed.
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
WESTLEY from HATTIESBURG, MS
Parts Used:
5303917954
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Fridge not cooling
My fridge side had warmed up to 70 degrees but the freezer side was still cold. The coils inside had iced up. After thawing with a hair dryer, it froze back after another week. I removed the old defrost thermostat and wired the heater strip directly and turned on the defrost timer. It began melting the ice so that ruled out the heater strip being bad. I couldn't get a reading with my ohm meter on the defrost thermostat so I took a chance and bought the part. Installation was a breeze and it fixed the problem.
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
earl a from GIRDLER, KY
Parts Used:
218906802
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
light blub blew
unplug power from ref removed old light socket only difference wired a little different checked new socket compaired to old checked terminal ends small big looked at wires big,little plugged up put in new light blub plugged ref power back on work power off pushed socket bac in power on works
4 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Matthew from SOUTH BEND, IN
Parts Used:
5303289051
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Light wouldn't turn on when door opened
Unplugged fridge, opened the door, used flat head screwdriver to pop off old switch, unplugged wires, plugged in new switch, popped it back in, and plugged the fridge back in. 2 minute fix.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jeff from GLENDORA, CA
Parts Used:
5303917954
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
freezer colk, refrig warm
Followed the instructions provided in your video, took less than 15 minutes and works like new. Thank you for the parts and the advice.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Justin from FRANKLIN, TN
Parts Used:
5300158289
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
The original fan motor began masking a noise and finally stoped working.
Followed video instruction and completed the replacement. I had to join the wires since the connector was a male plug to a make plug.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Kyle from Porter, OK
Parts Used:
5303917954
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Freezer coils kept freezing over.
1. Turned off the cooling cycle and unplugged the refrigerator.
2. Removed all of the shelving and bottom basket.
3. Removed rear covering in the freezer section.
4. If frosted over, manually defrost coils with hairdryer.
5. Located original thermostat and after marking the wire locations cut the wires and removed the Thermostat.
6. Connected matching wires using a lighter to melt the wires together. Wrapped repaired wires with electricians tape.
7. Unable to install the thermostat in the recommended location (freezer is a tight fit) the new part was installed at the original location.
8. Replaced the rear cover and shelves.
9. Plugged in the refrigerator and set the cycle back to cooling.
10. Monitored freezer coils couple of days/weeks depending on how fast they freeze over (slots at bottom of cover) to validate if problem solved.
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Denise from Landover, MD
Parts Used:
316538904
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
light bilb went out
replaced it
2 of 5 people found this instruction helpful.