Bernard from DONALDSONVLLE, LA
Parts Used:
W11745278
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
door hinge broke.
Removed door and replaced bushing bracket was ok.
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Chris from SACRAMENTO, CA
Parts Used:
W11700559
Difficulty Level:
Easy
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Screw drivers
Installed Ice Maker in Freezer
Installed ice machine components using kit and included instructions. Easy! Ran a copper line from under sink valve to back of refrigerator under the floor. Drilled two holes to run copper line. Plumber turned water off and replaced single valve with a double valve (one line to faucet and the other for the copper line). Installed shut off valve and filter at the other end of copper line. Then stainless hose to refrigerator. Everything went smooth. Double check the factory installed plastic line from the electric valve to the inlet for your freezer. Mine was barely inserted and leaked. I pushed it in all the way and it is fine now... Ice maker works really well! Wish I had done this sooner!
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Adam from GLOVERSVILLE, NY
Parts Used:
WPW10662129
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Plugged it in.
Not so good that was not the problem. Fan is not seized and all the lights work and display is not on but lights up as well. No start once plugged back in after 15 minutes of being unplugged. Nothing same no change.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jacqueline from LEXINGTON PK, MD
Parts Used:
WPW10662129
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Pliers
No cold
Like you video
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Michael from SALINA, KS
Parts Used:
W11700559
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
3 screws
Ice maker fit perfectly over 2 top screws. I tightened them and put the one on the bottom. I was done in less than 10minutes. Everything fit perfectly as expected. Couldn't have been eaiser. Parts Select is my go to online store.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Cathy from HOPATCONG, NJ
Parts Used:
W11384469
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Light rocker switch broke and refrigerator light couldn't go on.
I just popped out the old switch with a flat head screwdriver. Removed the connections and then installed new switch by reversing steps. Popped in back in and the light went on.
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
anthony from NORCROSS, GA
Parts Used:
W10822278
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
Freezer no longer frost free.
Reviewed Youtube video as a reference. Unplugged refrigerator. Removed old defrost timer. Matched the color of the wiring harness to the diagram that came with the part. Attach new part to wiring harness.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert from MERRIMACK, NH
Parts Used:
WP2196157
Difficulty Level:
Very Easy
Total Repair Time:
15 - 30 mins
Connection leaked as tube entered freezer
Followed video and had one problen, the metal pipe would not release as shown,so I used a hacksaw between the plastic and metal pipe, removing the metal pipe from inside as the video shows. Good instructions.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
charles from REDDING, CA
Parts Used:
W10822278
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
Warm refrigerater
Followed instructions from ideoo
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Doug from Lancaster, CA
Parts Used:
WPW10662129
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
compressor not running
Removed the access panel on back of unit located the Run Capacitor on the compressor and removed the bad one and put the new one on and pugged refrigerator back in and it started up and works fine now
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Barry from FORD CITY, PA
Parts Used:
WPW10662129
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Freezer occasionally had a temperature alarm.Clicking noise also.
Was told capacitor was problem 90% of the time.Capacior was not the problem.Bad start relay.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Scott from Jay, ME
Parts Used:
4387535
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
compressor clicks on for about 5 seconds and then shuts off, evaporator fan is running but no cooling in the fridge.
Disconnect power. Remove back panel on the refrigerator. Relay and overload is a modular unit attached to the compressor. Disconnect module from compressor, install new unit. While you're in there clean the condenser coils with a vacuum and clean the fan and condensate pan. Reassemble, and you're chillin. Total time approx. 15 min.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
MATTHEW from STOCKTON, CA
Parts Used:
4387478
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
The Light Socket Burned Out.
I pulled the socket out and unplugged the wires. I replaced the light socket by plugging in the wires and snapping the light socket into place. A very simple fix.
5 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
William from Fairfield Glade, TN
Parts Used:
W10822278
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Freezer Cold - Refrigerator Warm
After searching online to diagnose the issue with my refrigerator being warm and the freezer being cold and not shutting off to defrost I decided to get the defrost timer kit. The kit arrived within 2 day. With the directions included, after unplugging the appliance for safety, I installed it relatively quickly with only a screwdriver . I then plugged it back in and it immediately went to defrost. I thought, wow I have it fixed. Well unbeknownst to me it still didn't cool in the fridge area. After doing more internet research I found a suggestion to unplug the fridge for 24 hours to unthaw ice that may be lodged between the freezer and fridge that is blocking the distribution of cold air into the fridge. After doing this, it now works like a charm.
3 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Carolee from Spokane Valley, WA
Parts Used:
W11384469
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Light switch broke
Pried out old part with screwdriver. Unplugged. When new part came, just plugged it in and pushed the part into place.