Ather from Commerce, CA
Parts Used:
WR17X3670
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers
Water Line Broke that brings water to the Door
First Remove the screw and cover from the left top front of the fridge using a Phillips Screw Driver # 2
Then using a nut driver 1/4 of inch (or Socket set)
remove the two nuts holding the door hinge keeping the door in closed position. Now unplug the electrical connector between the door and the fridge body(Simply pulling it apart) Now hold the door from the middle and raise it up so that it can slide out from the bottom hole, on the main body
Now place the door on a table or a flat surface(Put may be a sheet or some thing to prevent the finish from getting scratched) Now remove the nuts around the inner panel of the door(nut Driver or Socket set) Remove the old lining and discard .Install the new lines and then replace every thing in the reverse order.
Note : Before tighting the top nuts of the door, make sure you keep the door aligened so you would not have to do it after completeing the job.
11 of 24 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jim from Jacksonville, FL
Parts Used:
WR17X2059
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
crushed ice feature inoperative, broken pieces in water dispensed.
Found broken pieces of deflector in delivered ice. Removed dispenser, carefully disassembled it, marking fasteners, sprimgs, and levers. Local repaimen say no replacement part available, must replace entire ice maker @ $350. Found exact part in your online reference, ordered at price of $3.76, part arrived two days later--perfect fit, exactly same as original. Reassembled, and it works exactly like new. Family very happy. Good job!!!!!
6 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
George from Brandywine, MD
Parts Used:
WR57X10051
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
no Ice
Turned off The water supply. Removed the back panel corner(nut driver). Removed valve (nut driver) and water supply inlet line. Cut the old outlet lines at the valve (new lines are push in) disconnected electrical lines, Reinstalled inlet line and electrical lines. Reinstalled valve and back panel. Turned on the water. Ice maker filled with water and a short time later I had ice. Easy job.
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Charles from Keller, TX
Parts Used:
WR30X10093
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Ice Maker would not fill.
Was concerned that new icemaker was quite a bit different than the one we were replacing. Called GE to confirm it was correct.

Went ahead and installed the unit, using the supplied electric cable adapter.

A little difficult to deal with the extra cable, but everything worked OK and it's making ice normally.
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Linda from Manorville, NY
Parts Used:
WR13X10020
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Socket set
door wouldn't close
First I propped up the door. Then I removed the 2 screws that hold the hinge on. AT this point you do need someone else because the door swings loose. I attached the new bracket and lowered the door. It went verey smooth. I ordered the new bracket after reading the installation stories from others who just repaced the plastic pieces. Its worth the extra money to just put on a new bracket
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Dean from Folsom, CA
Parts Used:
WR30X10093
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
The Icemaker failed to make ice
I pulled the refrigerator away from the wall and turned off the water to the refrigerator and unplugged it from the wall. After removing the icebucket from the freezer I located the mounting screws, loosened them, unplugged the electrical connection below the icemaker and carefully removed it from the freezer. I unpacked the replacement icemaker, matched it against the original and attached the electrical connection adapter. Using the slots provided on the new icemaker I placed it over the mounting screws after aligning the water inlet pipe properly. I tightened the mounting screws while maintaining the icemaker in a level position. I plugged in the electrical connector. Then I replaced the icebucket, plugged in the refigerator back into the 110VAC outlet, turned on the water and repositioned the refrigerator in it's normal position.
8 of 16 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Richard from Los Altos, CA
Parts Used:
WR02X10140
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Socket set
Hinge Cam Riser broke - door wouldn't self-close
I removed all of the items in the refrigerator door. I then removed the top hinge cover with a Philips screwdriver, and removed the two machine screws holding the top hinge using a socket wrench. This allowed me to lift the door off the bottom hinge pins and set the door on its side. I removed the two screws holding on the broken bottom hinge cam riser block and replace it with the new one. After tighening it back with a socket wrench, I tried to put the door back in place. I asked my wife to hold the door steady while I lay on the floor to guide the door downward over the bottom hinge pin. I then replaced the top hinge screws and checked the door. It still didn't close on its own! I realized I had to loosen the top hinge screws and adjust the door so that it stands more vertically (evening the gap with the freezer door). With this adjustment, the door closes fine.
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
robert from WOONSOCKET, RI
Parts Used:
WR51X10055
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers
Freezer coils were iced up,was not cold enough,suspected the heater was the culprit
I had looked at videos on you tube,it looked simple enough. I mostly do my own repairs so I gave it a shot. the job went well,if you do not fix things around the house don't try to do the repair,find a handyman in your neighborhood to help you out,cheaper than calling a refrigeration man. It is not that hard to do.
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from Randle, WA
Parts Used:
WR32X1492
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
The vegetable pan was broken from closing the door on it too hard when still open
I just slide the new one in place, using exsisting sliders. I had to remove the old grab handle from old pan and snap it into place on new pan.
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Cathy from San Antonio, TX
Parts Used:
WR17X3489
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Broken light shield in freezer
SUPER easy repair, taking about 5 minutes. After taking out the ice bin, I removed one small phillip's head screw, put the light shield in place, and tightened the screw.
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Scot from Fort Collins, CO
Parts Used:
WR17X4358
Difficulty Level:
Difficult
Total Repair Time:
More than 2 hours
Tools:
Nutdriver, Screw drivers, Wrench set
Tubing from vavle to reservoir had been degraded by compressor heat and had cracked, leaking water when door water dispenser was used.
- Disconnect the valve assembly and remove electrical connection to water dispenser valve to prevent accidental water discharge

- Disconnect tubing from valve assembly, remove and keep compression nut.

-Disconnect tubing from junction to door tube remove and keep compression nut

-Remove screws used to mount reservoir, pull tubing into main refrigerator compartment and remove old reservoir and tubing.

- Note that one of the tubes on the new reservoir is 2' too short.

- Go to hardware store to purchase 5/16" universal tubing compression junction.

- Install reservoir and feed tubing through holes in main refrigerator compartment.

- Route tubing through woven tubing protectors and clips.

- Trim tubing to length and install in valve using old compression nut.

- Splice the piece of tubing trimmed from supply side of reservoir to the outlet side tube using the fitting purchased from the hardware store.

- Connect end of tubing to existing junction using old compression nut.

- Re-connect wires to valve solonoid and test for leaks.

- Re-install valve assembly to refrigerator frame.
6 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Scott from South Lake Tahoe, CA
Parts Used:
WR17X4358
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Screw drivers
Dispenser Water Reservoir failed seem
This was a very easy fix. I cut the water lines at the reservoir, coupled the old lines to the new lines with two plastic barbed fittings used for outdoor drip irrigation. All I had to do was pull the old lines out and the new lines followed. Easy as pie!
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert from San Marcos, CA
Parts Used:
WR30X10093
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
no ice made
Performed self test.turned off ice maker switch four 5 minutes.Then turn on switch,within 10 seconds,pushed ice paddle 3 times,with 1 second in between each push.Push all the way back and release. Ice maker should cycle and squirt water. My ice maker did neither.I unplugged cord from fridge.So i replaced the ice maker.After a couple of screws had ice again !
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Daniel from St George, UT
Parts Used:
WR51X10055
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
Refrigerator temp went to 60 degrees
Freezer section defroster heater was inoperative.
turned off the refrigerator by turning the right knob in top rear refrigerator to 0.

Used hose on a vacuum sweeper blower side to feed warm air into the bottom rear section. Removed the top plastic panel behind the ice maker to allow air flow to exit through the fan to defrost the freezer coils.

Placed a flat oven pan into the area beside the vacuum hose and sponged up the melted frost water. After 30 minutes, water ceased to drain.

Removed freezer shelves, and 5 screws on rear freezer wall. It took about 2 minutes to remove the heater & braw assembly at the bottom of the coils. 2 screws have to be removed and wires just clip off and back on again. Replaced the 2 screws.

Replace rear coil wall cover and turn on the refrigerator to 5 to 7 and replace cover and shelves.
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Larry from Mount Airy, NC
Parts Used:
WR17X2059
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
would not crush ice
you must pay careful attention when taking the dispenser apart,especially the long rod that controls the deflector,but if close attention is payed to disassembly you should have no problem.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!