RD19F9WT3E Gibson Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- gustavo from gilroy, CA
- Parts Used:
- 5300158289
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Socket set
Fridge was warm and no cold air was coming in
The repair was straightfoward. The evaporator motor I received from partselect was a different model with different wiring configurations. I cut the wires from the new motor per the instructions I received with the new motor and I did the same with the wires that connect to the fridge. Once I matched the wires and secured them with electrical caps I began to put the evaporator motor to the base and started screwing the screws the way I took them off. Once I connected the wire harness to the back of the freezer and turned it on I noticed a big difference in air flow. I was surprised at how easy it was to fix my refrigirator problem. It's been a few weeks now and the fridge is cold and working like it should. Don't be afraid of this task. it's very easy and will save you a ton of money. Thanks partselect.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from Montross, VA
- Parts Used:
- 215846602
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Freezer dripped water and items thawed but compressor ran.
Instructions from partselect were very clear and probable cause made it easy to narrow things down. I have the manual for the refrigerator that shows the location of the defrost timer. Very surprised that it turned out to be a cheap and easy fix.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Janet from East Wenatchee, WA
- Parts Used:
- 215846602
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Coil, in freezer kept freezing up, refrigerator did not stay cold
Removed the timer, installed the new one. Great service from part select
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jim from Coulee City, WA
- Parts Used:
- 215846602
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
the fridge was freezing all the food.
I watched the video you had on-line and it was simple. Thank you so much
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- BILL from GENOA, WV
- Parts Used:
- 5303917954
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Refrig unit was frosting up top and bottom, did not properly defrost and stop cooling especially in lower compartment.
Unplug the refrigerator unit from wall. I removed freezer rack, plastic light cover, the ice rack shelf on the right side, then removed the plastic back cover panel, (4) retaining screws, gently tilting the panel toward me, unplug the wiring harness by depressing the clips on the side of the plug, removed panel from unit, set aside. If the unit was froze up, so I defrosted the cooling coils carefully with a common hair dryer until it was thawed. Be careful not to touch or bend the coils , since they are very fragile and SHARP! I located the old thermostat unit attached to a straight length of coolant line. The new unit looked like the old one, so it was easy to locate. I cut the two wires of the old unit close to the round base to make sure I would have enough wire to reconnect. Since my new unit did not indicate a polarity(Neg or Pos), I just wired each wire I cut to one of the new unit. I used the shrink tubing provided and heated the shrink till it was fully melted. I double ck'd to see if the wires were basically waterproof and a good connect. Also, before I replaced the rear panel, I made sure that both wires I had spliced had a drip loop to it so water would not drip down into the newly spliced union. Also made sure the wires will not interfere with the colling fan on the back of the rear panel. Reverse the procedure in reassembling. Plug in unit, and wait and listen for the unit coming back on..I kept a regular thermometer in the upper and lower compartments. Allow 24 hrs. for the unit to return to normal operation. It may defrost several times till the whole operation is back in sync.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- HUNG from KENT, WA
- Parts Used:
- 215846602
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
refregirator too warm
I order defrost timer then replaced it but it seemed doesn't work. I order defrost thermostat again then it worked fine until now. Thanks. Part selects.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Donald from Round Rock, TX
- Parts Used:
- 215846602
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Weird Noise that continued for at least 60 seconds control OFF.
Unplug the refrigerator. Removed the right hand top shelf. Used a 1/4" nutdriver to remove rear center mounting screw for Control Housing. Used Phillips screwdriver to remove two mounting screws for timer. Unplug cable from timer and plug it into the new timer. Install the new timer and re-install the Control Housing. Plug in the refrigerator and adjust the timer to start the unit. This was a snap with the diagnostic provided by Part Select. At first I thought it was the fan rubbing but when I removed the cover (two screws) it was obvious that wasn't the problem. The diagnostic hinted that it was either the timer or the motor capacitor making the noise. Because the noise continued after turning OFF the control, I thought it was the timer...I was right.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Stephen from West Columbia, SC
- Parts Used:
- 218730609
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
gasket was torn
removed everything from door, removed screws in gasket around door, laid door face down(insulation side up)applied rtv around edge of gasket and door, waited 10 minutes and started with top screw in middle of top then middle of sides and bottom then installed remaining screws checked levelness of refrigerator, the you are done
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Armando from Eagle pass, TX
- Parts Used:
- 5300158289
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
the evaporator fan same time won't stater
change the evaporator fan motor kit working perfect
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Gerry from Apache Jct, AZ
- Parts Used:
- 215846602
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
changed defrost timer
followed the video very esay
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ed from Memphis, TN
- Parts Used:
- 215846602
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Unit keep cutting off
Ordered the new part-Unplugged the refrigerator - took off the cover over the defective timer - put in the new part put the cover back on - plugged the refrigerator back in - so far, so good!~
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- thomas from Chepachet, RI
- Parts Used:
- 215846602
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Screw drivers
at first auto defrost would not work so I had to take the frezer panel apart and defrost it with a hair dryer every ten days
pulled down the thermostat cover and unpluged the timer control and replaced it with the new part. total time to repair was about 15 min. there was a vidio on how to replace the new part that just informed me that I did it right!!!!very easy site to find what you are looking for!!!!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Joseph from Tullahoma, TN
- Parts Used:
- 215846602
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Freezer and main compartment had wide temperature variations
I first thought the defroster heater broke - took the back wall of the freezer off and cooling fins were fine. Then took the defroster timer out and opened it up. The contacts were badly burnt so the compressor and fan ran during only part of the cooling cycle. Replacing the timer took less than 5 minutes - turn off the power, remove one screw to take out the control box, cut the ground wire (new timer housing is plastic and does not have a ground connection), remove two screws to unmount the timer, unplug the old timer, plug in the new timer, fasten with two screws, put the control unit in and fasten with one screw, turn power back on.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mark from Hertford, NC
- Parts Used:
- 215846602
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Screw drivers
Refrigerator Ran Constantly, Was not Cooling as well.
Looked up troubleshooting info on your web site. Decided to replace the defrost timer. Ordered it using Paypal. Received the Shipment in about 1.5 days in Rural NC. Watched Your Video, cut off power to the fridge, removed the top self and unbolted the panel, removed the defective defrost timer, installed the new one and re-installed the panel and top shelf. Set the timer to defrost to check the operation (looked inside the freezer to see that the defroster was glowing red - it was) waited about twenty minutes to ensure that the fridge started cooling again. Fixed!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Robert from Jacksonville, FL
- Parts Used:
- 215846602
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Screw drivers
Refrig would not defrost
Diagnosis: used wiring diagram attached to frig and determined cause could be wiring, heater element, thermostat or timer. After completely defrosting the frig (turned it off) I removed the rear cover in the freezer and looked for an obvious problem. None seen. Removed temperature select pod from the frig box and looked for obvious problems. None seen but defrost timer appeared poorly made. Repair: Since I had no practical way of checking the defrost cycle in operation, I checked probable failures on the Part Select website and saw defrost timer as most probable. I ordered the timer. Installed it. Waited a few days to make sure the frig went through a few defrost cycles then removed the freezer rear cover. There was no excessive frost buildup so I'm reasonably sure the repair was successful.
Was this instruction helpful to you?
Thank you for voting!