Customer:
LUIS from CENTENNIAL, CO
Parts Used:
215846602
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Freezer built ice, fridge not cold enough and running constantly.
Removed front low grill, removed the two screws that hold the element in place. I then pulled the element out about 3 inches and disconnected the wires. Reversed process to install new timer.
1 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
steve from Kirkland, WA
Parts Used:
215846602
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
freezer worked frig was warm. Ice maker is still not working
Removed two screws to get to defrost time pull panel down remove two screws holding time and reinstall
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
brad from minneapolis, MN
Parts Used:
5303917954, 215846602
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
Freezer okay, but fridge was warm
Website was great!

The defrost timer was right in front. 2 minutes and a screwdriver and I had it replaced.

To replace the thermostat, I had to take out the back panel, defrost it and then install the new part. the only problem was that the heatshrink tubing they sent was too large. Otherwise, it worked great.
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Thomas from Stuart, FL
Parts Used:
215846602
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
coil Iceing up
took 4 screws out of the discharge vent on top of the refrigerator section and unpluged the wiring harness and put the section on the counter and unscrewed the timer and put the new one in and reinstalled the assembly and plugged the Jack and put the 4 screws back in, and rotated the timer and put it on defrost removed the back and check the heaters and drain .
0 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ronald from Defiance, OH
Parts Used:
215846602
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
leaking water down into fridge
just like the video showed...it was excellent!!!
0 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
doug from Franklin, TX
Parts Used:
5300158289
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers
bottom of fridge quit cooling
dismantled the top rear panel of the freezer and found I had the wrong part. Hand started the fan motor and it has been working fine since.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Gary from Dunnellon, FL
Parts Used:
215846602
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
both ref&frez were hot
1 went with maj 69% said defrost timer. NO. 2 went with second choice run cap NO. 3 went with my thought, ( PTC Starter ) why not, most exp part. Fixed the problem.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ed from Glendale, CA
Parts Used:
215846602
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers, Screw drivers
ice buil up on freezer,not defrosting
first I replaced the timer control hoping thats the problem,unfortunately situation the same ice build up on the freezer.so I replaced the defrost thermostat.right now I'll still observing the condition if still the same.may be in couple days.so far its good.and to replace the parts is not difficult and easy.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Eric from San Angelo, TX
Parts Used:
5308000010, 5300158289
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Socket set
Fan Motor was making noise and freezing up.Fan was missing one blade.
Removed screws that fastened bracket to fridge. Next, I replaced the motor and carefully lined the brackets up so the motor would rotate smoothly. Put the fan blade on the motor and screwed the brackets back on the fridge. Motor kept popping out of alignment while I was screwing the brackets back in but I kept snapping it back in till it stayed.
Was this instruction helpful to you?
Thank you for voting!
Customer:
mark from murrieta, CA
Parts Used:
5303917954
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers
the freezer coils were not defrosting so they would ice up and cut off the cold air into the refrigerator side
there were three possible problems the timer, the thermostat, or the heating element.i replaced the timer first as that is the problem 65% of the time and that did not fix the problem, i replaced the thermostat and that did fix the problem. after watching the video on line from parts select i took the back off of the freezer from the inside, defrosted the coils with a hair blower and then swapped out the thermostat which pops right off and i spliced the old connectors to the new thermostat. the heat shrink tubing that came with the part was a little to big so i put a smaller peice on each side for water proofing. that is what the cigarette lighter is for to supply heat to the heat shrink tubing.now that i have fixed that problem i may tackle the ice maker next
Was this instruction helpful to you?
Thank you for voting!
Customer:
Roger from Owatonna, MN
Parts Used:
215846602
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
It would freeze up or not cool at all, depended where the clock stopped.
Removed the lower trim panel from front of fridg. and loosened two screws enough to turn it about 1/4 inch so the screw heads were in the larger holes. Pulled it out disconnected the wire connector and transfered the heat shield and screws to the new clock, connected the wire connector and aligned the screws. tightened them and job done. Has worked like new sense. Thanks Roger
Was this instruction helpful to you?
Thank you for voting!
Customer:
hugh from delray beach, FL
Parts Used:
215846602
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Frig did not run
Simply replaced the defrost timer located inside the frig just behind the temp dial. Very easy job. Removed the 3 screws holding the temp sw and light assembly. Removed the defrost timer w/ 2 screws and put i all back together. 15 mins at most. Suggest you watch the install video for pointers.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from Long Beach, CA
Parts Used:
215846602
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers, Socket set
Freezer wouldn't go in to defrost cycle
After some troubleshooting to ensure the thermostat and heating element were working, determined that the defrost timer was the problem. With the defective part, I was able to manually advance the timer to activate the defrost cycle, but it wouldn't do so on its own. Unplugged the refrigerator from the wall. Timer is located in the refrigerator compartment at the very top. The compartment houses the cooling thermostat, the light bulb and the defrost timer. Using 1/4" nut driver, remove 4 screws holding compartment cover to top of fridge. Lower a bit to access electrical wiring. Wiring harness can be unplugged to work on the timer away from the fridge which makes it a bit easier. Timer is mounted with 2 phillips head screws. Remove screws and unplug timer from wiring. Install new timer, plug in wiring, secure with the phillips head screws and remount entire compartment.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Bertha from Lakewood, CA
Parts Used:
215846602
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Socket set
Refrigerator warm and freezer defrosting too quickly.
1. Disconnected electrical. 2. Removed upper console in refrigerator by removing 2 nuts. 3. Disconnected wiring from console. 4. Removed 2 screws from defroster timer part and pulled off from connector. 5. Replaced with new defroster timer and put everything back together. Thank you Steve for the U-Tube step by step video.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mainul from Portland, OR
Parts Used:
215846602
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
The refrigerator part was not cooling enough
I watched the video online where it described the troubleshooting tips for this type of symptom. So I knew exactly what the problem was which is the defrost timer. After the part came in I just unscrewed (4 screws) the box which houses the thermostat and the defrost timer from top ceiling of the refrigerator section. Then I just unscrewed and unhooked the old defrost timer and replaced it with the new one. After finishing the installation I turned the fridge on. At first nothing happened. So I turned the dial on the defrost timer with a flathead screw until it clicked and the fridge came alive. I waited for an hour or so. The cooling cycle completed and the fridge stopped as expected. When I opened the door I noticed the interior is much colder than before and right after closing the door the fridge hummed back into life again. So I know my fridge is working again. Thanks to PartSelect for providing the right part for my refrigerator. I will definitely buy from them again if anything goes wrong.